{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,25]],"date-time":"2025-06-25T05:09:40Z","timestamp":1750828180506},"reference-count":25,"publisher":"Georg Thieme Verlag KG","issue":"03","license":[{"start":{"date-parts":[[2021,8,23]],"date-time":"2021-08-23T00:00:00Z","timestamp":1629676800000},"content-version":"vor","delay-in-days":53,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Radiol Imaging"],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Background\u2003Mammography has been established as the key modality in the detection and diagnosis of breast cancers. Digital breast tomosynthesis (DBT) has emerged as a mammographic technique which allows improved visualization of abnormalities by reducing the effect of overlapping breast tissue.<\/jats:p><jats:p>\n          Purpose\u2003This article is a pictorial essay which highlights the advantages of DBT with two-dimensional (2D) synthesized mammography (2DSM) images, its clinical applications, and its role in breast imaging.<\/jats:p><jats:p>\n          Materials and Methods\u2003Selenia Dimensions HD mammography machine performs DBT which acquires a series of low-dose digital mammographic images of the compressed breast followed by full-field digital mammography. Software using specialized algorithms helps to create a 2DSM image reconstructed from the DBT data set. The images are interpreted on a dedicated work station on high-resolution monitors by the radiologist. American College of Radiology Breast Imaging-Reporting and Data System (BI-RADS) lexicon is used for reporting. High-resolution breast ultrasound which includes evaluation of the axilla is done for all cases.<\/jats:p><jats:p>\n          Conclusion\u2003DBT improves detection and better characterization of lesions which thereby increases confidence of interpretation of mammograms and assigning BI-RADS categories for further management.<\/jats:p>","DOI":"10.1055\/s-0041-1734378","type":"journal-article","created":{"date-parts":[[2021,8,23]],"date-time":"2021-08-23T23:04:48Z","timestamp":1629759888000},"page":"678-688","source":"Crossref","is-referenced-by-count":1,"title":["Utility of Digital Breast Tomosynthesis with Two-Dimensional Synthesized Mammography Images: A Pictorial Essay"],"prefix":"10.1055","volume":"31","author":[{"given":"Pradipta C.","family":"Hande","sequence":"additional","affiliation":[{"name":"Division of Radiology, Department of Imaging, Breach Candy Hospital Trust, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sabita S.","family":"Desai","sequence":"additional","affiliation":[{"name":"Department of Radiology, Breach Candy Hospital Trust, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarabjeet K.","family":"Arneja","sequence":"additional","affiliation":[{"name":"Department of Surgical Pathology and Cytology, Breach Candy Hospital Trust, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sreedevi","family":"Sathian","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Breach Candy Hospital Trust, Mumbai, Maharashtra, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2021,8,23]]},"reference":[{"issue":"01","key":"ref1","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1111\/tbj.12354","article-title":"Insights from the breast cancer screening trials: how screening affects the natural history of breast cancer and implications for evaluating service screening programs","volume":"21","author":"L Tab\u00e1r","year":"2015","journal-title":"Breast J"},{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"256","DOI":"10.2214\/AJR.16.17127","article-title":"Advances in digital breast tomosynthesis","volume":"208","author":"R J Hooley","year":"2017","journal-title":"AJR Am J Roentgenol"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1148\/radiol.2251011667","article-title":"Comparison of the performance of screening mammography, physical examination, and breast US and evaluation of factors that influence them: an analysis of 27,825 patient evaluations","volume":"225","author":"T M Kolb","year":"2002","journal-title":"Radiology"},{"issue":"02","key":"ref4","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.breast.2014.12.002","article-title":"Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography","volume":"24","author":"T M Svahn","year":"2015","journal-title":"Breast"},{"issue":"03","key":"ref5","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1148\/radiol.13131391","article-title":"Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images","volume":"271","author":"P Skaane","year":"2014","journal-title":"Radiology"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1148\/rg.2015140204","article-title":"Merchant JK, Mayo RC III, Harvey JA. Digital breast tomosynthesis in the diagnostic setting: indications and clinical applications","volume":"35","author":"H R Peppard","year":"2015","journal-title":"Radiographics"},{"issue":"08","key":"ref8","doi-asserted-by":"crossref","first-page":"2538","DOI":"10.1007\/s00330-015-4083-7","article-title":"Comparison between two-dimensional synthetic mammography reconstructed from digital breast tomosynthesis and full-field digital mammography for the detection of T1 breast cancer","volume":"26","author":"J S Choi","year":"2016","journal-title":"Eur Radiol"},{"key":"ref9","author":"E A Sickles"},{"issue":"01","key":"ref10","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1148\/radiol.12120552","article-title":"Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions","volume":"266","author":"M L Zuley","year":"2013","journal-title":"Radiology"},{"issue":"01","key":"ref11","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1148\/radiol.13130765","article-title":"Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations","volume":"270","author":"P A Dang","year":"2014","journal-title":"Radiology"},{"issue":"02","key":"ref12","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1148\/rg.342135082","article-title":"Digital breast tomosynthesis in the analysis of fat-containing lesions","volume":"34","author":"P E Freer","year":"2014","journal-title":"Radiographics"},{"issue":"12","key":"ref13","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1016\/j.crad.2013.07.006","article-title":"Assessment of extent of breast cancer: comparison between digital breast tomosynthesis and full-field digital mammography","volume":"68","author":"H S Mun","year":"2013","journal-title":"Clin Radiol"},{"issue":"07","key":"ref14","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1007\/s11547-013-0941-z","article-title":"Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI","volume":"118","author":"A Luparia","year":"2013","journal-title":"Radiol Med (Torino"},{"issue":"12","key":"ref15","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1055\/s-0032-1313102","article-title":"Breast microcalcifications as type descriptors to stratify risk of malignancy: a systematic review and meta-analysis of 10665 cases with special focus on round\/punctate microcalcifications","volume":"184","author":"M Rominger","year":"2012","journal-title":"R\u00f6fo Fortschr Geb R\u00f6ntgenstr Nuklearmed"},{"key":"ref16","first-page":"623","volume":"36","author":"A A Rao","year":"2016"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"65","DOI":"10.4103\/2156-7514.124099","article-title":"Preliminary clinical experience with digital breast tomosynthesis in the visualization of breast microcalcifications","volume":"3","author":"S V Destounis","year":"2013","journal-title":"J Clin Imaging Sci"},{"issue":"02","key":"ref18","doi-asserted-by":"crossref","first-page":"320","DOI":"10.2214\/AJR.10.4656","article-title":"Detection and classification of calcifications on digital breast tomosynthesis and 2D digital mammography: a comparison","volume":"196","author":"M L Spangler","year":"2011","journal-title":"AJR Am J Roentgenol"},{"issue":"06","key":"ref19","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1111\/j.1524-4741.2011.01152.x","article-title":"Calcifications in the breast and digital breast tomosynthesis","volume":"17","author":"D Kopans","year":"2011","journal-title":"Breast J"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1148\/rg.2016150123","article-title":"Developing asymmetries at mammography: a multimodality approach to assessment and management","volume":"36","author":"A L Chesebro","year":"2016","journal-title":"Radiographics"},{"issue":"03","key":"ref21","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1148\/radiol.14132759","article-title":"The developing asymmetry: revisiting a perceptual and diagnostic challenge","volume":"274","author":"E R Price","year":"2015","journal-title":"Radiology"},{"issue":"02","key":"ref22","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1148\/rg.2016150093","article-title":"Tomosynthesis-detected architectural distortion: management algorithm with radiologic-pathologic correlation","volume":"36","author":"M A Durand","year":"2016","journal-title":"Radiographics"},{"key":"ref23","author":"J A Harvey","year":"2013"},{"issue":"04","key":"ref24","doi-asserted-by":"crossref","first-page":"926","DOI":"10.2214\/AJR.17.19271","article-title":"Artifacts in digital breast tomosynthesis","volume":"211","author":"W R Geiser","year":"2018","journal-title":"AJR Am J Roentgenol"},{"issue":"02","key":"ref25","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1007\/s00330-017-5024-4","article-title":"Radiation dose with digital breast tomosynthesis compared to digital mammography: per-view analysis","volume":"28","author":"G Gennaro","year":"2018","journal-title":"Eur Radiol"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.clinimag.2019.01.014","article-title":"Quantitative analysis of radiation dosage and image quality between digital breast tomosynthesis (DBT) with two-dimensional synthetic mammography and full-field digital mammography (FFDM","volume":"55","author":"Y Choi","year":"2019","journal-title":"Clin Imaging"}],"container-title":["Indian Journal of Radiology and Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0041-1734378.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,13]],"date-time":"2021-11-13T23:35:32Z","timestamp":1636846532000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0041-1734378"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":25,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2021,11,13]]},"published-print":{"date-parts":[[2021,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0041-1734378","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0971-3026","1998-3808"],"issn-type":[{"value":"0971-3026","type":"print"},{"value":"1998-3808","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7]]}}}