{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T10:40:08Z","timestamp":1730803208342,"version":"3.28.0"},"reference-count":5,"publisher":"Georg Thieme Verlag KG","issue":"04","license":[{"start":{"date-parts":[[2024,4,21]],"date-time":"2024-04-21T00:00:00Z","timestamp":1713657600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Radiol Imaging"],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Introduction\u2003Central venous catheterization is a common tool widely used in medical treatment for long-term intravenous administration of medication (e.g. chemotherapy or antibiotics) or parenteral nutrition. Here, we present a case of a missing peripherally inserted central catheter (PICC) which was detected on computed tomography (CT) scan thorax.<\/jats:p><jats:p>\n          Case Report\u2003A 50-year-old female admitted for follow-up for adenocarcinoma rectum was found to have a missing PICC line and advised CT thorax for evaluation. The imaging findings revealed coiled PICC line in the right atrium extending to inferior vena cava and into right ventricle and further extending and coiled PICC is seen in the main, right, and left pulmonary arteries. Through emergency interventional procedure, the PICC line was successfully retrieved percutaneously via the right femoral vein.<\/jats:p><jats:p>\n          Conclusion\u2003PICC fracture is less common and always seen without significant discomfort if not found timely, and it may lead to serious complications, such as pulmonary embolism, and even death. Early detection and removal may help to prevent signi\ufb01cant mortality.<\/jats:p>","DOI":"10.1055\/s-0042-1744234","type":"journal-article","created":{"date-parts":[[2024,4,21]],"date-time":"2024-04-21T22:30:20Z","timestamp":1713738620000},"page":"754-756","source":"Crossref","is-referenced-by-count":0,"title":["Migrated Peripherally Inserted Central Catheter in the Right Ventricle and Bilateral Pulmonary Arteries: A Case Report"],"prefix":"10.1055","volume":"34","author":[{"given":"Reena","family":"Anand","sequence":"additional","affiliation":[{"name":"Department of Radiology, Max Superspeciality Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vineeta","family":"Dagar","sequence":"additional","affiliation":[{"name":"Department of Radiology, Max Superspeciality Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajeev","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Max Superspeciality Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandeep","family":"Batra","sequence":"additional","affiliation":[{"name":"Department of Oncology, Max Superspeciality Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,4,21]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"8","DOI":"10.2309\/java.16-1-3","article-title":"PICC-related thrombosis: pathophysiology, incidence, morbidity and the effect of ultrasound-guided placement technique on occurrence in cancer patients","volume":"16","author":"M E Huhhes","year":"2011","journal-title":"J Assoc Vasc Access"},{"issue":"02","key":"ref2","first-page":"202","article-title":"Endovascular techniques and procedures, methods for removal of intravascular foreign bodies","volume":"25","author":"J M Motta Leal Filho","year":"2010","journal-title":"Rev Bras Cir Cardiovasc"},{"key":"ref3","first-page":"555555","article-title":"Retrieval of a broken peripherally inserted central catheter migrated in the right pulmonary artery in a young girl: a case report","volume":"1","author":"W Zhang","year":"2015","journal-title":"J Cardiol & Cardiovasc Ther"},{"key":"ref4","first-page":"379","volume-title":"Percutaneous retrieval of intravascular foreign bodies","author":"S Kadir","year":"1982"},{"issue":"09","key":"ref5","doi-asserted-by":"crossref","first-page":"369","DOI":"10.4330\/wjc.v5.i9.369","article-title":"Endovascular technique using a snare and suture for retrieving a migrated peripherally inserted central catheter in the left pulmonary artery","volume":"5","author":"H Teragawa","year":"2013","journal-title":"World J Cardiol"}],"container-title":["Indian Journal of Radiology and Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1744234.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T10:12:16Z","timestamp":1730801536000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1744234"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,21]]},"references-count":5,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2024,9,23]]},"published-print":{"date-parts":[[2024,10]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1744234","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0971-3026","1998-3808"],"issn-type":[{"type":"print","value":"0971-3026"},{"type":"electronic","value":"1998-3808"}],"subject":[],"published":{"date-parts":[[2024,4,21]]}}}