{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,6]],"date-time":"2026-04-06T12:11:05Z","timestamp":1775477465495,"version":"3.50.1"},"reference-count":20,"publisher":"Georg Thieme Verlag KG","issue":"08","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Thorac Cardiovasc Surg"],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003Despite the recent trend of access miniaturization in minimally invasive cardiac surgery (MICS) surgical \u201ccut down (CD)\u201d for femoral cannulation remains the standard at many centers. Percutaneous vascular closure (PVC) devices have recently been introduced for minimizing invasiveness during interventional diagnostic and therapy. This report summarizes the initial experience with this new approach in the setting of MICS, with a special focus on safety and advantages.<\/jats:p><jats:p>\n          Methods\u2003Percutaneous cannulation with a standard protocol including preoperative computer tomography imaging and intraoperative point-of-care ultrasound guidance was performed in 93 consecutive patients from September 2018 until February 2020, while conventional \u201cCD\u201d procedure performed in 218 patients in the previous period. We analyzed patients' characteristics and compared access site complications of PVC group versus conventional \u201cCD\u201d group.<\/jats:p><jats:p>\n          Results\u2003As far as operative\/postoperative outcome, the duration of intensive care unit stay as well as hospital stay was statistically shorter in PVC compared with CD (CD vs. PVC: 2.74\u2009\u00b1\u20093.83 vs. 2.16\u2009\u00b1\u20092.01 days, p\u2009&lt;\u20090.01, 16.7\u2009\u00b1\u20098.75 vs. 13.0\u2009\u00b1\u20094.96 days, p\u2009&lt;\u20090.001, respectively). Further, we found no femoral infection or lymphocele in the PVC group, whereas 4 cases of wound complications were observed in the CD group.<\/jats:p><jats:p>\n          Conclusion\u2003According to our results, percutaneous closure system for femoral vessels in MICS seems to be beneficial with the assist of preoperative computed tomography and intraoperative Doppler guidance.<\/jats:p>","DOI":"10.1055\/s-0042-1745812","type":"journal-article","created":{"date-parts":[[2022,7,28]],"date-time":"2022-07-28T01:44:27Z","timestamp":1658972667000},"page":"641-647","source":"Crossref","is-referenced-by-count":3,"title":["Percutaneous Cannulation of Femoral Vessels in Minimally Invasive Cardiac Surgery"],"prefix":"10.1055","volume":"71","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0217-7363","authenticated-orcid":false,"given":"Yukiharu","family":"Sugimura","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hassan","family":"Jandali","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Angiology and Internal Intensive Care Medicine, Rhineland Clinic, Dormagen, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1051-8105","authenticated-orcid":false,"given":"Moritz Benjamin","family":"Immohr","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shintaro","family":"Katahira","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"},{"name":"Department of Cardiothoracic Surgery, University Hospital, Tohoku University, Sendai, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan-Philipp","family":"Minol","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8580-6369","authenticated-orcid":false,"given":"Artur","family":"Lichtenberg","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6452-8678","authenticated-orcid":false,"given":"Payam","family":"Akhyari","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery and Research Group for Experimental Surgery, Medical Faculty, Heinrich Heine University, D\u00fcsseldorf, Germany"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2022,7,27]]},"reference":[{"issue":"07","key":"ref1","doi-asserted-by":"crossref","first-page":"875","DOI":"10.1016\/j.carrev.2020.03.032","article-title":"Safety and effectiveness of MANTA vascular closure device after large-bore mechanical circulatory support: Real-world experience","volume":"21","author":"A Gupta","year":"2020","journal-title":"Cardiovasc Revasc Med"},{"issue":"08","key":"ref2","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1016\/j.amjcard.2020.01.021","article-title":"Meta-analysis comparing percutaneous to surgical access in trans-femoral transcatheter aortic valve implantation","volume":"125","author":"H K Abdelaziz","year":"2020","journal-title":"Am J Cardiol"},{"issue":"15","key":"ref3","doi-asserted-by":"crossref","first-page":"e1558","DOI":"10.4244\/EIJ-D-18-00769","article-title":"Propensity-matched comparison of vascular closure devices after transcatheter aortic valve replacement using MANTA versus ProGlide","volume":"14","author":"N Moriyama","year":"2019","journal-title":"EuroIntervention"},{"issue":"02","key":"ref4","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1111\/joic.12459","article-title":"Vascular complications after percutaneous mitral valve repair and venous access closure using suture or closure device","volume":"31","author":"B Steppich","year":"2018","journal-title":"J Interv Cardiol"},{"issue":"02","key":"ref5","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1111\/joic.12468","article-title":"The novel echo-guided ProGlide technique during percutaneous transfemoral transcatheter aortic valve implantation","volume":"31","author":"Y Honda","year":"2018","journal-title":"J Interv Cardiol"},{"issue":"01","key":"ref6","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s42155-018-0026-0","article-title":"Access site complications after transfemoral aortic valve implantation - a comparison of Manta and ProGlide","volume":"1","author":"P Hoffmann","year":"2018","journal-title":"CVIR Endovasc"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.ijcard.2018.04.065","article-title":"MANTA versus ProGlide vascular closure devices in transfemoral transcatheter aortic valve implantation","volume":"263","author":"F Biancari","year":"2018","journal-title":"Int J Cardiol"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"E55","DOI":"10.1002\/ccd.26686","article-title":"Comparative data of single versus double ProGlide vascular preclose technique after percutaneous transfemoral transcatheter aortic valve implantation from the optimized catheter valvular intervention (OCEAN-TAVI) Japanese multicenter registry","volume":"90","author":"A Kodama","year":"2017","journal-title":"Catheter Cardiovasc Interv"},{"issue":"16","key":"ref9","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.4244\/EIJ-D-16-00408","article-title":"Propensity-matched comparison of percutaneous and surgical cut-down approaches in transfemoral transcatheter aortic valve implantation using a balloon-expandable valve","volume":"12","author":"H Kawashima","year":"2017","journal-title":"EuroIntervention"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1177\/1526602816689679","article-title":"Safety and efficacy of totally percutaneous access compared with open femoral exposure for endovascular aneurysm repair: a meta-analysis","volume":"24","author":"Z Cao","year":"2017","journal-title":"J Endovasc Ther"},{"issue":"06","key":"ref11","doi-asserted-by":"crossref","first-page":"1927","DOI":"10.1016\/j.athoracsur.2016.09.098","article-title":"Complications associated with femoral cannulation during minimally invasive cardiac surgery","volume":"103","author":"J Lamelas","year":"2017","journal-title":"Ann Thorac Surg"},{"issue":"45","key":"ref12","doi-asserted-by":"crossref","first-page":"e17910","DOI":"10.1097\/MD.0000000000017910","article-title":"Feasibility and safety of total percutaneous closure of femoral arterial access sites after veno-arterial extracorporeal membrane oxygenation","volume":"98","author":"X Xu","year":"2019","journal-title":"Medicine (Baltimore)"},{"issue":"04","key":"ref13","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/j.jvs.2015.10.067","article-title":"Percutaneous removal using Perclose ProGlide closure devices versus surgical removal for weaning after percutaneous cannulation for venoarterial extracorporeal membrane oxygenation","volume":"63","author":"J W Hwang","year":"2016","journal-title":"J Vasc Surg"},{"issue":"06","key":"ref14","first-page":"739","article-title":"Total percutaneous femoral vessels cannulation for minimally invasive mitral valve surgery","volume":"2","author":"M Pozzi","year":"2013","journal-title":"Ann Cardiothorac Surg"},{"issue":"01","key":"ref15","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.athoracsur.2019.10.038","article-title":"Percutaneous vascular closure device in minimally invasive mitral valve surgery","volume":"110","author":"M Kastengren","year":"2019","journal-title":"Ann Thorac Surg"},{"issue":"01","key":"ref16","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1186\/s13019-021-01400-6","article-title":"Impact of standardized computed tomographic angiography for minimally invasive mitral and tricuspid valve surgery","volume":"16","author":"M B Immohr","year":"2021","journal-title":"J Cardiothorac Surg"},{"issue":"02","key":"ref17","first-page":"280","article-title":"Cumulative sum analysis of the learning curve for the preclosure technique using Proglide","volume":"30","author":"H Gao","year":"2020","journal-title":"Interact Cardiovasc Thorac Surg"},{"issue":"04","key":"ref18","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/j.ejvs.2019.03.037","article-title":"Factors in ProGlide\u00ae vascular closure failure in sheath arteriotomies greater than 16 French","volume":"58","author":"I M Chen","year":"2019","journal-title":"Eur J Vasc Endovasc Surg"},{"issue":"04","key":"ref19","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1016\/j.jvir.2016.12.1219","article-title":"Predictive factors for additional ProGlide deployment in percutaneous endovascular aortic repair","volume":"28","author":"S Y Lin","year":"2017","journal-title":"J Vasc Interv Radiol"},{"issue":"03","key":"ref20","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1161\/CIRCULATIONAHA.121.057856","article-title":"Comparison of a pure plug-based versus a primary suture-based vascular closure device strategy for transfemoral transcatheter aortic valve replacement: the CHOICE-CLOSURE randomized clinical trial","volume":"145","author":"M Abdel-Wahab","year":"2022","journal-title":"Circulation"}],"container-title":["The Thoracic and Cardiovascular Surgeon"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1745812.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,4]],"date-time":"2023-12-04T23:45:58Z","timestamp":1701733558000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1745812"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,27]]},"references-count":20,"journal-issue":{"issue":"08","published-online":{"date-parts":[[2023,12,4]]},"published-print":{"date-parts":[[2023,12]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1745812","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0171-6425","1439-1902"],"issn-type":[{"value":"0171-6425","type":"print"},{"value":"1439-1902","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,27]]}}}