{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T20:09:52Z","timestamp":1788466192987,"version":"build-2803163510"},"reference-count":29,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2022,9]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Objective\u2003The aim of this study was to describe an arthroscopic-assisted technique for coxofemoral toggle rod placement, and to report on the feasibility, drill tunnel trajectory and accuracy of tunnel aperture location using this method.<\/jats:p>\n                  <jats:p>Study Design\u2003Cadaveric pilot study.<\/jats:p>\n                  <jats:p>Sample Population\u2003Eight coxofemoral joints.<\/jats:p>\n                  <jats:p>Methods\u2003Craniodorsal coxofemoral joint luxations were artificially created. A simulated open hip reduction and stabilization with a toggle rod were performed through a limited arthrotomy under arthroscopic guidance. Computed tomography scans were performed to evaluate drill hole trajectory across the femoral neck, and joints were disarticulated and photographed. Digital imaging software was used to determine the percent overlap of the drill hole apertures relative to the origin and insertion of the round ligament on the acetabulum and fovea.<\/jats:p>\n                  <jats:p>Results\u2003The exit point of the tunnel was entirely within the fovea capitis in five of eight femurs, three of eight femoral drill apertures were only partially within the target area. Of the eight acetabular bone tunnels examined, all were centred occupying the acetabular fossa.<\/jats:p>\n                  <jats:p>Conclusions\u2003Coxofemoral toggle rod placement can be performed under arthroscopic guidance through a limited arthrotomy. Comparable femoral tunnel accuracy with the standard open technique should be achieved with the current method prior to its clinical use.<\/jats:p>","DOI":"10.1055\/s-0042-1748880","type":"journal-article","created":{"date-parts":[[2022,7,19]],"date-time":"2022-07-19T18:57:50Z","timestamp":1658257070000},"page":"298-304","source":"Crossref","is-referenced-by-count":3,"title":["Arthroscopic-Assisted Toggle Rod Stabilization in Canine Coxofemoral Luxation: A Cadaveric Study"],"prefix":"10.1055","volume":"35","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1833-6915","authenticated-orcid":false,"given":"Rachel E.","family":"Rivenburg","sequence":"additional","affiliation":[{"name":"Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, Urbana, Illinois, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean M.","family":"Murphy","sequence":"additional","affiliation":[{"name":"WestVet Animal Specialty & Emergency Center, Garden City, Idaho, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ciaran T.","family":"Jones","sequence":"additional","affiliation":[{"name":"Gilabbey Veterinary Hospital, Cork, Munster, Ireland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyle W.","family":"Martin","sequence":"additional","affiliation":[{"name":"Colorado Animal Specialty & Emergency, Boulder, Colorado, United States"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2022,7,19]]},"reference":[{"issue":"05","key":"ref1","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1111\/j.1532-950X.1987.tb00965.x","article-title":"A retrospective study of prosthetic capsule technique for the treatment of problem cases of dislocated hips","volume":"16","author":"M E Johnson","year":"1987","journal-title":"Vet Surg"},{"issue":"03","key":"ref2","doi-asserted-by":"crossref","first-page":"268","DOI":"10.5326\/15473317-36-3-268","article-title":"Spontaneous bilateral coxofemoral luxation in four dogs","volume":"36","author":"C D Trostel","year":"2000","journal-title":"J Am Anim Hosp Assoc"},{"issue":"12","key":"ref3","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.2460\/javma.254.12.1436","article-title":"Analysis of outcomes following treatment of craniodorsal hip luxation with closed reduction and Ehmer sling application in dogs","volume":"254","author":"A N Schlag","year":"2019","journal-title":"J Am Vet Med Assoc"},{"issue":"05","key":"ref4","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1111\/j.1532-950X.2014.12158.x","article-title":"Hip toggle stabilization using the TightRope\u00ae system in 17 dogs: technique and long-term outcome","volume":"43","author":"N R Kieves","year":"2014","journal-title":"Vet Surg"},{"key":"ref5","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1111\/j.1532-950X.1984.tb00807.x","article-title":"Traumatic coxofemoral luxation in dogs. Results of repair","volume":"13","author":"D L Bone","year":"1984","journal-title":"Vet Surg"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"984","DOI":"10.2460\/javma.229.6.984","article-title":"Toggle rod stabilization for treatment of hip joint luxation in dogs: 62 cases (2000-2005)","volume":"229","author":"J L Demko","year":"2006","journal-title":"J Am Vet Med Assoc"},{"issue":"01","key":"ref7","doi-asserted-by":"crossref","first-page":"81","DOI":"10.2460\/javma.1996.208.01.81","article-title":"Use of a modified toggle pin for repair of coxofemoral luxation in dogs with multiple orthopedic injuries: 14 cases (1986-1994)","volume":"208","author":"H P Beckham Jr","year":"1996","journal-title":"J Am Vet Med Assoc"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1111\/vsu.13498","article-title":"Risk factors for reluxation after toggle rod stabilization for treatment of coxofemoral luxation in 128 dogs","volume":"50","author":"M E Mathews","year":"2021","journal-title":"Vet Surg"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"182","DOI":"10.3415\/VCOT-09-08-0087","article-title":"Combined intra-extra-articular technique for stabilisation of coxofemoral luxation. Preliminary results in two dogs","volume":"23","author":"A Venturini","year":"2010","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"500","DOI":"10.17221\/7035-VETMED","article-title":"Caudal approach and MiniTightRope system (mTR) application for the treatment of craniodorsal hip luxation in a cat: a case report","volume":"58","author":"R Tamburro","year":"2013","journal-title":"Vet Med (Praha)"},{"key":"ref11","first-page":"140","volume-title":"Bones of the Pelvic Limb","author":"H E Evans","year":"2013","edition":"4th edition:"},{"issue":"05","key":"ref12","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1055\/s-0038-1667064","article-title":"Evaluation of modified techniques for toggle pin repair of coxofemoral luxation in dogs: a cadaveric study","volume":"31","author":"J I Helmick","year":"2018","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1055\/s-0038-1632552","article-title":"Closed toggle pinning for canine traumatic coxofemoral luxation","volume":"12","author":"M G Serdy","year":"1999","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"03","key":"ref14","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1111\/jsap.12765","article-title":"Minimally invasive technique for coxofemoral luxation stabilisation using transarticular toggle system: a cadaveric study","volume":"59","author":"U Segal","year":"2018","journal-title":"J Small Anim Pract"},{"issue":"07","key":"ref15","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1111\/vsu.12937","article-title":"Arthroscopic placement of a toggle rod to correct coxofemoral luxation in a dog","volume":"47","author":"P J Rocheleau","year":"2018","journal-title":"Vet Surg"},{"issue":"01","key":"ref16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1055\/s-0040-1719169","article-title":"Accuracy of patient-specific 3D printed drill guides in the placement of a canine coxofemoral toggle pin through a minimally invasive approach","volume":"34","author":"B G Darrow","year":"2021","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1111\/j.1532-950X.1985.tb00883.x","article-title":"Inclination and anteversion angles of the femoral head and neck in the dog: evaluation of a standard method of measurement","volume":"14","author":"P M Montavon","year":"1985","journal-title":"Vet Surg"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"43","DOI":"10.4236\/ss.2012.31007","article-title":"The 45-degree arthroscope improves visualization of the femoral attachment of the anterior cruciate ligament","volume":"3","author":"K Okazaki","year":"2012","journal-title":"Surg Sci"},{"issue":"04","key":"ref19","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.otsr.2019.02.003","article-title":"The 45 degrees arthroscope: a forgotten scope in knee surgery","volume":"105","author":"P P Mariani","year":"2019","journal-title":"Orthop Traumatol Surg Res"},{"issue":"03","key":"ref20","doi-asserted-by":"crossref","first-page":"e541","DOI":"10.3928\/01477447-20161229-02","article-title":"Deep infections after syndesmotic fixation with a suture button device","volume":"40","author":"A J Fantry","year":"2017","journal-title":"Orthopedics"},{"issue":"08","key":"ref21","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1111\/vsu.12952","article-title":"Mechanical analysis of suture attachment methods in toggle suture constructs","volume":"47","author":"K A Kraska","year":"2018","journal-title":"Vet Surg"},{"issue":"07","key":"ref22","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1111\/j.1532-950X.2013.12049.x","article-title":"Assessment of the craniocaudal stability of four extracapsular stabilization techniques during two cyclic loading protocols: a cadaver study","volume":"42","author":"C J Choate","year":"2013","journal-title":"Vet Surg"},{"issue":"02","key":"ref23","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1111\/j.1532-950X.2009.00637.x","article-title":"In vitro biomechanical evaluation and comparison of FiberWire, FiberTape, OrthoFiber, and nylon leader line for potential use during extraarticular stabilization of canine cruciate deficient stifles","volume":"39","author":"R Burgess","year":"2010","journal-title":"Vet Surg"},{"issue":"05","key":"ref25","doi-asserted-by":"crossref","first-page":"721","DOI":"10.2460\/ajvr.2001.62.721","article-title":"Biomechanical analysis of suture anchors and suture materials used for toggle pin stabilization of hip joint luxation in dogs","volume":"62","author":"W I Baltzer","year":"2001","journal-title":"Am J Vet Res"},{"issue":"08","key":"ref26","doi-asserted-by":"crossref","first-page":"948","DOI":"10.1111\/j.1532-950X.2012.01028.x","article-title":"Mechanical analysis of twelve toggle suture constructs for stabilization of coxofemoral luxations","volume":"41","author":"S Jha","year":"2012","journal-title":"Vet Surg"},{"issue":"02","key":"ref27","doi-asserted-by":"crossref","first-page":"83","DOI":"10.5326\/JAAHA-MS-6937","article-title":"Coxofemoral joint luxation in dogs treated with toggle rod stabilization: a multi-institutional retrospective review with client survey","volume":"56","author":"C T Trostel","year":"2020","journal-title":"J Am Anim Hosp Assoc"},{"issue":"01","key":"ref28","doi-asserted-by":"crossref","first-page":"54","DOI":"10.3415\/VCOT-11-02-0019","article-title":"Correction of craniodorsal coxofemoral luxation in cats and small breed dogs using a modified Knowles technique with the braided polyblend TightRope systems","volume":"25","author":"K Ash","year":"2012","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"02","key":"ref29","doi-asserted-by":"crossref","first-page":"665","DOI":"10.1007\/s11999-012-2593-z","article-title":"Bacteria adhere less to barbed monofilament than braided sutures in a contaminated wound model","volume":"471","author":"J R Fowler","year":"2013","journal-title":"Clin Orthop Relat Res"},{"issue":"06","key":"ref30","doi-asserted-by":"crossref","first-page":"834","DOI":"10.1016\/j.arthro.2011.02.003","article-title":"Bacterial adherence to high\u2013tensile strength sutures","volume":"27","author":"B D Masini","year":"2011","journal-title":"Arthroscopy"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1748880.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T21:34:50Z","timestamp":1764106490000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1748880"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,19]]},"references-count":29,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2022,10,18]]},"published-print":{"date-parts":[[2022,9]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1748880","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,19]]}}}