{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T20:17:57Z","timestamp":1788293877134,"version":"build-2803163510"},"reference-count":44,"publisher":"Georg Thieme Verlag KG","issue":"02","license":[{"start":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T00:00:00Z","timestamp":1667952000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Eur J Dent"],"published-print":{"date-parts":[[2023,5]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003The removable partial denture must keep health of the remaining teeth and the supporting tissues through the distribution of chewing forces on the abutment teeth and alveolar process.<\/jats:p><jats:p>This study aimed to evaluate stress distribution with canines-supported mandibular overdenture retained by two different attachment types: ball attachments or resilient telescopic crowns.<\/jats:p><jats:p>\n          Materials and Methods\u2003Two 3-dimensional finite element models consisting of the cortical mandible bone, cancellous mandible bone, oral mucosa, canines, periodontal ligaments, the two attachment types, and overdenture were simulated. The models were imported into the mathematical analysis software Ansys Workbench V 15.0. All materials were considered to be homogeneous, isotropic, and linearly elastic. A vertical bilateral load of 120\u2009N was applied to the central fossa of the first molars. The von Mises stress was calculated for canines, cortical, and cancellous bone.<\/jats:p><jats:p>\n          Results\u2003The maximum von Mises stress of the ball attachments model was 35.61, 4.28, 7.82, and 1.29 MPa for canines, cortical alveolar bone of canines, cortical alveolar bone at the distal end of the overdenture, and cancellous alveolar bone of canines, respectively. The maximum von Mises stress of the resilient telescopic crowns model was 39.22, 4.74, 7.06, and 1.05 MPa for canines, cortical alveolar bone of canines, cortical alveolar bone at the distal end of the overdenture, and cancellous alveolar bone of canines, respectively.<\/jats:p><jats:p>\n          Conclusion\u2003Resilient telescopic crowns distribute the stresses between canines, alveolar bone of canines, and overdenture supporting alveolar bone. Ball attachments transfer less stress to the canines and cortical alveolar bone of the canines, but more stress to the cancellous alveolar bone of canines and alveolar bone at distal end of the overdenture. Resilient telescopic crowns are preferred over ball attachment when the abutment teeth have good periodontal support.<\/jats:p>","DOI":"10.1055\/s-0042-1749363","type":"journal-article","created":{"date-parts":[[2022,11,9]],"date-time":"2022-11-09T23:52:46Z","timestamp":1668037966000},"page":"539-547","source":"Crossref","is-referenced-by-count":14,"title":["Finite Element Study of Stress Distribution with Tooth-Supported Mandibular Overdenture Retained by Ball Attachments or Resilient Telescopic Crowns"],"prefix":"10.1055","volume":"17","author":[{"given":"Nour M.T.","family":"Ajaj AL-Kordy","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohannad H.","family":"AL-Saadi","sequence":"additional","affiliation":[{"name":"Department of Removable Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2022,11,9]]},"reference":[{"issue":"02","key":"ref1","first-page":"181","article-title":"Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns\u2013a finite element analysis","volume":"93","author":"M RA Abbasi","year":"2020","journal-title":"Med Pharm Rep"},{"issue":"10","key":"ref2","first-page":"1","article-title":"Assessment of contact pressures between a mandibular overdenture and the prosthodontic area","volume":"11","author":"M Idzior-Haufa","year":"2021","journal-title":"Appl Sci (Basel)"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1111\/j.1532-849X.2012.00905.x","article-title":"A systematic review of the clinical performance of tooth\u2010retained and implant\u2010retained double crown prostheses with a follow\u2010up of\u2265 3 years","volume":"22","author":"R Verma","year":"2013","journal-title":"J Prosthodont"},{"issue":"03","key":"ref4","first-page":"207","article-title":"Clinical longevity of removable partial dentures retained by telescopic crowns: outcome of the double crown with clearance fit","volume":"14","author":"H J Wenz","year":"2001","journal-title":"Int J Prosthodont"},{"issue":"04","key":"ref5","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.sdentj.2015.03.001","article-title":"A finite element study on stress distribution of two different attachment designs under implant supported overdenture","volume":"27","author":"M I El-Anwar","year":"2015","journal-title":"Saudi Dent J"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"176","DOI":"10.4103\/0974-6781.140905","article-title":"Selection of attachment systems in fabricating an implant supported overdenture","volume":"4","author":"D K Prasad","year":"2014","journal-title":"J Dent Implant"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"246","DOI":"10.2174\/1874210601812010246","article-title":"Telescopic denture","volume":"12","author":"M A Hakkoum","year":"2018","journal-title":"Open Dent J"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.prosdent.2014.02.017","article-title":"Double-crown\u2013retained removable dental prostheses: a retrospective study of survival and complications","volume":"112","author":"F S Schwindling","year":"2014","journal-title":"J Prosthet Dent"},{"issue":"05","key":"ref9","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1016\/0022-3913(80)90070-0","article-title":"Telescope retainers and their clinical application","volume":"44","author":"A Langer","year":"1980","journal-title":"J Prosthet Dent"},{"issue":"04","key":"ref10","doi-asserted-by":"crossref","first-page":"337","DOI":"10.2334\/josnusd.54.337","article-title":"Clinical evaluation of failures in removable partial dentures","volume":"54","author":"J H Jorge","year":"2012","journal-title":"J Oral Sci"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"132","DOI":"10.2174\/1874210601509010132","article-title":"Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study","volume":"9","author":"L J Dula","year":"2015","journal-title":"Open Dent J"},{"issue":"10","key":"ref12","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3390\/ma14102598","article-title":"A comparison of biomechanical properties of implant-retained overdenture based on precision attachment type","volume":"14","author":"M Idzior-Haufa","year":"2021","journal-title":"Materials (Basel)"},{"issue":"04","key":"ref13","doi-asserted-by":"crossref","first-page":"228","DOI":"10.34172\/joddd.2020.047","article-title":"Number of dental abutments influencing the biomechanical behavior of tooth-implant-supported fixed partial dentures: a finite element analysis","volume":"14","author":"J C De Oliveira","year":"2020","journal-title":"J Dent Res Dent Clin Dent Prospect"},{"issue":"01","key":"ref14","first-page":"1","article-title":"A three-dimensional finite element analysis of mechanical function for 4 removable partial denture designs with 3 framework materials: CoCr, Ti-6Al-4V alloy and PEEK","volume":"9","author":"X Chen","year":"2019","journal-title":"Sci Rep"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1155\/2021\/5699962","article-title":"Biomechanics in removable partial dentures: a literature review of FEA-based studies","volume":"2021","author":"M A Mousa","year":"2021","journal-title":"BioMed Res Int"},{"key":"ref16","first-page":"1","volume-title":"Finite Element Analysis and Its Applications in Dentistry","author":"V Bandela","year":"2020"},{"issue":"03","key":"ref17","first-page":"342","article-title":"Finite element study on corono-radicular restored teeth","volume":"2","author":"S Liliana","year":"2012","journal-title":"Inter J Model Optim"},{"issue":"04","key":"ref18","doi-asserted-by":"crossref","first-page":"369","DOI":"10.21726\/rsbo.v10i4.948","article-title":"Application of the finite element method in dentistry","volume":"10","author":"M AR Piccioni","year":"2013","journal-title":"RSBO"},{"issue":"03","key":"ref19","doi-asserted-by":"crossref","first-page":"425","DOI":"10.4103\/0970-9290.70813","article-title":"Infinite to finite: an overview of finite element analysis","volume":"21","author":"A Srirekha","year":"2010","journal-title":"Indian J Dent Res"},{"issue":"04","key":"ref20","first-page":"10579","article-title":"Modelling and finite element method in dentistry","volume":"20","author":"A A \u015ete\u0163iu","year":"2015","journal-title":"Rom Biotechnol Lett"},{"key":"ref21","first-page":"67","volume-title":"Chapter 3: Finite element analysis in dentistry","author":"J B Meira","year":"2018"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.5772\/38037","volume-title":"Chapter 1: Past, present and future of finite element analysis in dentistry","author":"C C Ko","year":"2012"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12903-020-01208-1","article-title":"A review of virtual planning software for guided implant surgery-data import and visualization, drill guide design and manufacturing","volume":"20","author":"F Kernen","year":"2020","journal-title":"BMC Oral Health"},{"issue":"05","key":"ref24","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.prosdent.2017.07.016","article-title":"Stress distribution of single-implant\u2013retained overdenture reinforced with a framework: a finite element analysis study","volume":"119","author":"C F Amaral","year":"2018","journal-title":"J Prosthet Dent"},{"issue":"01","key":"ref25","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1186\/s41205-020-00069-2","article-title":"DICOM segmentation and STL creation for 3D printing: a process and software package comparison for osseous anatomy","volume":"6","author":"T Kamio","year":"2020","journal-title":"3D Print Med"},{"issue":"02","key":"ref26","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.medengphy.2007.02.005","article-title":"A complete finite element model of a mandibular implant-retained overdenture with two implants: comparison between rigid and resilient attachment configurations","volume":"30","author":"M Daas","year":"2008","journal-title":"Med Eng Phys"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1111\/j.1600-0501.2004.01064.x","article-title":"Mandibular two\u2010implant telescopic overdentures: 10\u2010year clinical and radiographical results","volume":"15","author":"S M Heckmann","year":"2004","journal-title":"Clin Oral Implants Res"},{"issue":"03","key":"ref28","doi-asserted-by":"crossref","first-page":"200","DOI":"10.4103\/1735-3327.255745","article-title":"Effect of thread depth and implant shape on stress distribution in anterior and posterior regions of mandible bone: a finite element analysis","volume":"16","author":"F A Hussein","year":"2019","journal-title":"Den Res J"},{"issue":"06","key":"ref29","doi-asserted-by":"crossref","first-page":"351","DOI":"10.4047\/jap.2020.12.6.351","article-title":"Effects of overdenture attachment systems with different working principles on stress transmission: a three-dimensional finite element study","volume":"12","author":"N Turker","year":"2020","journal-title":"J Adv Prosthodont"},{"issue":"04","key":"ref30","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1097\/00029330-200602020-00007","article-title":"Three-dimensional finite element analysis of weakened roots restored with different cements in combination with titanium alloy posts","volume":"119","author":"L L Li","year":"2006","journal-title":"Chin Med J (Engl)"},{"issue":"01","key":"ref31","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1055\/s-0040-1715915","article-title":"Pediatric stainless-steel crown cementation finite element study","volume":"15","author":"A S Waly","year":"2021","journal-title":"Eur J Dent"},{"issue":"05","key":"ref32","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1016\/j.prosdent.2014.04.023","article-title":"Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position","volume":"112","author":"R Shahmiri","year":"2014","journal-title":"J Prosthet Dent"},{"issue":"01","key":"ref33","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jds.2012.01.001","article-title":"Effects of the type and rigidity of the retainer and the number of abutting teeth on stress distribution of telescopic-retained removable partial dentures","volume":"7","author":"V Sahin","year":"2012","journal-title":"J Dent Sci"},{"issue":"02","key":"ref34","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.prosdent.2016.10.032","article-title":"Finite element analysis of implant-assisted removable partial dentures: framework design considerations","volume":"118","author":"R Shahmiri","year":"2017","journal-title":"J Prosthet Dent"},{"issue":"07","key":"ref35","first-page":"1","article-title":"Shape optimization for additive manufacturing of removable partial dentures-a new paradigm for prosthetic CAD\/CAM","volume":"10","author":"J Chen","year":"2015","journal-title":"PLoS One"},{"issue":"04","key":"ref36","doi-asserted-by":"crossref","first-page":"478","DOI":"10.1016\/j.jobcr.2021.06.004","article-title":"Stress distribution and patient satisfaction in flexible and cast metal removable partial dentures: finite element analysis and randomized pilot study","volume":"11","author":"N Kumar","year":"2021","journal-title":"J Oral Biol Craniofac Res"},{"issue":"04","key":"ref37","doi-asserted-by":"crossref","first-page":"224","DOI":"10.2186\/prp.5.224","article-title":"Finite element stress analysis of overdenture abutment as a function of crown-to-root ratio","volume":"5","author":"T Tanaka","year":"2006","journal-title":"Prosthodont Res Prac"},{"issue":"01","key":"ref38","first-page":"21","article-title":"Three-dimensional finite element analysis and comparison of stress distribution in overdentures supported with bar attachments and telescopic crowns","volume":"2","author":"S Pan","year":"1999","journal-title":"Chin J Dent Res"},{"issue":"09","key":"ref39","doi-asserted-by":"crossref","first-page":"1512","DOI":"10.3390\/ma11091512","article-title":"FEM investigation of the stress distribution over mandibular bone due to screwed overdenture positioned on dental implants","volume":"11","author":"M Cicci\u00f9","year":"2018","journal-title":"Materials (Basel)"},{"issue":"09","key":"ref40","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1080\/10255842.2017.1319941","article-title":"Biomechanical evaluation of the natural abutment teeth in combined tooth-implant-supported telescopic prostheses: a three-dimensional finite element analysis","volume":"20","author":"Y Chen","year":"2017","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"ref41","doi-asserted-by":"crossref","first-page":"3126","DOI":"10.1590\/1679-78253212","article-title":"Finite element study of three different treatment designs of a mandibular three implant-retained overdenture","volume":"13","author":"M Shishesaz","year":"2016","journal-title":"Lat Am J Solids Struct"},{"issue":"09","key":"ref42","first-page":"196","article-title":"Finite element stress analysis of overdentures supported by angled implants","volume":"2","author":"B E Gul","year":"2014","journal-title":"Merit Res J Med Med Sci"},{"issue":"03","key":"ref43","first-page":"183","article-title":"Biodynamics of attachments used in overdentures: experimental analysis with photoelasticity","volume":"28","author":"C Labaig","year":"1997","journal-title":"Quintessence Int"},{"issue":"03","key":"ref44","first-page":"133","article-title":"Biomechanical analysis of distal extension removable partial dentures with different retainers","volume":"3","author":"H E Lee","year":"2008","journal-title":"J Dent Sci"}],"container-title":["European Journal of Dentistry"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1749363.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,9]],"date-time":"2023-07-09T22:45:19Z","timestamp":1688942719000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1749363"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,9]]},"references-count":44,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2023,7,8]]},"published-print":{"date-parts":[[2023,5]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1749363","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1305-7456","1305-7464"],"issn-type":[{"value":"1305-7456","type":"print"},{"value":"1305-7464","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,9]]}}}