{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T12:59:45Z","timestamp":1763643585792,"version":"3.37.3"},"reference-count":7,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2022,8,16]],"date-time":"2022-08-16T00:00:00Z","timestamp":1660608000000},"content-version":"vor","delay-in-days":227,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["European J Pediatr Surg Rep."],"published-print":{"date-parts":[[2022,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Laparoscopic surgery has been applied for Hirschsprung's disease (HD). We herein report our approach to mesenteric processing for laparoscopic-assisted transanal endorectal pull-through (L-TERPT). Following mucosectomy and entering the abdominal cavity, a vessel sealing system is transanally inserted into the abdominal cavity for mesenteric processing based on concept of Natural Orifice Translumenal Endoscopic Surgery. Since the transanal axis is parallel to the dissected mesentery, it makes easier to operate in comparison to when the procedure is performed through the abdominal working port and can reduce the additional abdominal trocar wound. We also use indocyanine green (ICG) fluorescence navigation. Fluorescing the vessels with ICG allows intraoperative visualization of the blood flow in the retrieved intestine. With these innovative combined techniques, L-TERPT for HD can be safely performed, even in infants with small intraabdominal cavities.<\/jats:p>","DOI":"10.1055\/s-0042-1751051","type":"journal-article","created":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T01:06:38Z","timestamp":1660698398000},"page":"e115-e117","source":"Crossref","is-referenced-by-count":4,"title":["Transanal Mesenteric Resection in Hirschsprung's Disease Using ICG under Concept of NOTES Technique"],"prefix":"10.1055","volume":"10","author":[{"given":"Mitsuru","family":"Muto","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3984-3764","authenticated-orcid":false,"given":"Shun","family":"Onishi","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masakazu","family":"Murakami","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keisuke","family":"Yano","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshio","family":"Harumatsu","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1250-093X","authenticated-orcid":false,"given":"Satoshi","family":"Ieiri","sequence":"additional","affiliation":[{"name":"Department of Pediatric Surgery, Kagoshima University, Kagoshima, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2022,8,16]]},"reference":[{"issue":"04","key":"ref1","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1089\/lps.1994.4.273","article-title":"Laparoscopic Duhamel pullthrough procedure for Hirschsprung's disease in childhood","volume":"4","author":"B M Smith","year":"1994","journal-title":"J Laparoendosc Surg"},{"issue":"07","key":"ref2","doi-asserted-by":"crossref","first-page":"1017","DOI":"10.1016\/0022-3468(95)90333-X","article-title":"Primary laparoscopic pull-through for Hirschsprung's disease in infants and children","volume":"30","author":"K E Georgeson","year":"1995","journal-title":"J Pediatr Surg"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1055\/s-2008-1066459","article-title":"Laparoscopic Swenson's procedure in children","volume":"6","author":"K Hoffmann","year":"1996","journal-title":"Eur J Pediatr Surg"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"894","DOI":"10.1016\/S0022-3468(97)90645-X","article-title":"Laparoscopic pull-through procedures using the harmonic scalpel in infants and children with Hirschsprung's disease","volume":"32","author":"S S Rothenberg","year":"1997","journal-title":"J Pediatr Surg"},{"issue":"10","key":"ref5","doi-asserted-by":"crossref","first-page":"3135","DOI":"10.1007\/s00464-011-1718-x","article-title":"Natural orifice translumenal endoscopic surgery (NOTES(\u00ae)): a technical review","volume":"25","author":"E D Auyang","year":"2011","journal-title":"Surg Endosc"},{"key":"ref6","doi-asserted-by":"crossref","first-page":"65","DOI":"10.2152\/jmi.66.65","article-title":"Usefulness of blood flow evaluation by indocyanine green fluorescence system in laparoscopic anterior resection","volume":"66","author":"J Higashijima","year":"2019","journal-title":"J Med Invest"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1093\/bjs\/znaa139","article-title":"Indocyanine green fluorescence angiography versus standard intraoperative methods for prevention of anastomotic leak in colorectal surgery: meta-analysis","volume":"108","author":"S Trastulli","year":"2021","journal-title":"Br J Surg"}],"container-title":["European Journal of Pediatric Surgery Reports"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1751051.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T01:07:12Z","timestamp":1660698432000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1751051"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1]]},"references-count":7,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2022,1,15]]},"published-print":{"date-parts":[[2022,1]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1751051","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2194-7619","2194-7627"],"issn-type":[{"type":"print","value":"2194-7619"},{"type":"electronic","value":"2194-7627"}],"subject":[],"published":{"date-parts":[[2022,1]]}}}