{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T17:45:19Z","timestamp":1792950319529,"version":"4.5.0"},"reference-count":40,"publisher":"Georg Thieme Verlag KG","issue":"03","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Semin intervent Radiol"],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Inferior vena cava filters are an important therapeutic option for patients with venous thromboembolism and contraindication to anticoagulation. Indications for filter placement have varied over the previous decades. This article discusses the history of inferior vena cava filter use, with a basic overview of technology and specific devices. Finally, this article reviews emerging filter design and technology. Understanding the basics of inferior vena cava filters is critical to building more robust clinical data for the purpose of improving patient outcomes.<\/jats:p>","DOI":"10.1055\/s-0042-1751294","type":"journal-article","created":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T22:35:10Z","timestamp":1661985310000},"page":"226-233","source":"Crossref","is-referenced-by-count":6,"title":["Back to the Basics: Inferior Vena Cava Filters"],"prefix":"10.1055","volume":"39","author":[{"given":"Brian","family":"Covello","sequence":"additional","affiliation":[{"name":"Department of Interventional Radiology, Aventura Hospital and Medical Center, Aventura, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Radvany","sequence":"additional","affiliation":[{"name":"Department of Neurointerventional Radiology, Aventura Hospital and Medical Center, Aventura, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2022,8,31]]},"reference":[{"issue":"09","key":"ref1","doi-asserted-by":"crossref","first-page":"1027","DOI":"10.1016\/j.jacc.2015.12.028","article-title":"Vena caval filter utilization and outcomes in pulmonary embolism: Medicare hospitalizations from 1999 to 2010","volume":"67","author":"B Bikdeli","year":"2016","journal-title":"J Am Coll Cardiol"},{"issue":"06","key":"ref2","doi-asserted-by":"crossref","first-page":"2579","DOI":"10.1016\/j.chest.2020.08.002","article-title":"Inferior vena cava filters: past, present, and future","volume":"158","author":"R M Marron","year":"2020","journal-title":"Chest"},{"issue":"03","key":"ref3","first-page":"5","article-title":"Anticoagulation therapy for venous thromboembolism","volume":"6","author":"D K Cundiff","year":"2004","journal-title":"MedGenMed"},{"issue":"04","key":"ref4","doi-asserted-by":"crossref","first-page":"425","DOI":"10.1097\/01.RVI.0000064860.87207.77","article-title":"Update on inferior vena cava filters","volume":"14","author":"T B Kinney","year":"2003","journal-title":"J Vasc Interv Radiol"},{"issue":"02","key":"ref5","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1067\/mva.2000.108645","article-title":"Kazi Mobin-Uddin, 1930-1999","volume":"32","author":"S A Hussain","year":"2000","journal-title":"J Vasc Surg"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1056\/NEJM197201132860202","article-title":"Transvenous caval interruption with umbrella filter","volume":"286","author":"K Mobin-Uddin","year":"1972","journal-title":"N Engl J Med"},{"issue":"04","key":"ref7","first-page":"599","article-title":"A new intracaval filter permitting continued flow and resolution of emboli","volume":"73","author":"L J Greenfield","year":"1973","journal-title":"Surgery"},{"issue":"02","key":"ref8","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1148\/radiology.151.2.6709930","article-title":"Kimray-Greenfield vena cava filter: percutaneous introduction","volume":"151","author":"S M Tadavarthy","year":"1984","journal-title":"Radiology"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1055\/s-2006-948760","article-title":"Inferior vena cava filters","volume":"23","author":"T B Kinney","year":"2006","journal-title":"Semin Intervent Radiol"},{"issue":"02","key":"ref10","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0741-5214(95)70265-2","article-title":"Comparative efficacy and complications of vena caval filters","volume":"21","author":"C R Mohan","year":"1995","journal-title":"J Vasc Surg"},{"issue":"04","key":"ref11","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1016\/j.jjcc.2012.05.002","article-title":"Complications of temporary vena cava filter placement","volume":"60","author":"H Wada","year":"2012","journal-title":"J Cardiol"},{"issue":"01","key":"ref12","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1148\/radiology.172.1.2662247","article-title":"Experience with the Amplatz retrievable vena cava filter","volume":"172","author":"D H Epstein","year":"1989","journal-title":"Radiology"},{"issue":"06","key":"ref13","doi-asserted-by":"crossref","first-page":"e003957","DOI":"10.1161\/CIRCINTERVENTIONS.116.003957","article-title":"Defining prolonged dwell time: when are advanced inferior vena cava filter retrieval techniques necessary? An analysis in 762 procedures","volume":"10","author":"K R Desai","year":"2017","journal-title":"Circ Cardiovasc Interv"},{"issue":"02","key":"ref14","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1055\/s-0036-1581088","article-title":"Inferior vena cava filters: guidelines, best practice, and expanding indications","volume":"33","author":"E DeYoung","year":"2016","journal-title":"Semin Intervent Radiol"},{"issue":"07","key":"ref15","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1056\/NEJM199802123380701","article-title":"A clinical trial of vena caval filters in the prevention of pulmonary embolism in patients with proximal deep-vein thrombosis. Pr\u00e9vention du Risque d'Embolie Pulmonaire par Interruption Cave Study Group","volume":"338","author":"H Decousus","year":"1998","journal-title":"N Engl J Med"},{"issue":"12","key":"ref16","doi-asserted-by":"crossref","first-page":"1861","DOI":"10.1001\/jamainternmed.2017.5960","article-title":"Trends in inferior vena cava filter placement by indication in the United States from 2005 to 2014","volume":"177","author":"M J Saeed","year":"2017","journal-title":"JAMA Intern Med"},{"issue":"09","key":"ref17","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1001\/jamainternmed.2017.2719","article-title":"Association between contemporary trends in inferior vena cava filter placement and the 2010 US Food and Drug Administration Advisory","volume":"177","author":"S Reddy","year":"2017","journal-title":"JAMA Intern Med"},{"issue":"06","key":"ref18","doi-asserted-by":"crossref","first-page":"1502","DOI":"10.1007\/s00270-015-1112-5","article-title":"The CIRSE Retrievable IVC Filter Registry: retrieval success rates in practice","volume":"38","author":"M J Lee","year":"2015","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"10","key":"ref19","doi-asserted-by":"crossref","first-page":"1529","DOI":"10.1016\/j.jvir.2020.06.014","article-title":"Society of Interventional Radiology Clinical Practice Guideline for inferior vena cava filters in the treatment of patients with venous thromboembolic disease: developed in collaboration with the American College of Cardiology, American College of Chest Physicians, American College of Surgeons Committee on Trauma, American Heart Association, Society for Vascular Surgery, and Society for Vascular Medicine","volume":"31","author":"J A Kaufman","year":"2020","journal-title":"J Vasc Interv Radiol"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.jvsv.2019.07.009","article-title":"Predicting the safety and effectiveness of inferior vena cava filters study: design of a unique safety and effectiveness study of inferior vena cava filters in clinical practice","volume":"8","author":"D L Gillespie","year":"2020","journal-title":"J Vasc Surg Venous Lymphat Disord"},{"issue":"02","key":"ref21","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1055\/s-0036-1583208","article-title":"Evidence-based evaluation of inferior vena cava filter complications based on filter type","volume":"33","author":"S E Deso","year":"2016","journal-title":"Semin Intervent Radiol"},{"issue":"02","key":"ref22","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1055\/s-0036-1582123","article-title":"Permanent versus retrievable inferior vena cava filters: rethinking the \u201cone-filter-for-all\u201d approach to mechanical thromboembolic prophylaxis","volume":"33","author":"C E Ghatan","year":"2016","journal-title":"Semin Intervent Radiol"},{"issue":"02","key":"ref23","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jvir.2019.08.036","article-title":"Final two-year outcomes for the Sentry bioconvertible inferior vena cava filter in patients requiring temporary protection from pulmonary embolism","volume":"31","author":"M D Dake","year":"2020","journal-title":"J Vasc Interv Radiol"},{"issue":"05","key":"ref24","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/S1051-0443(93)71950-8","article-title":"Deployment problems with the titanium Greenfield filter","volume":"4","author":"T J Sweeney","year":"1993","journal-title":"J Vasc Interv Radiol"},{"issue":"04","key":"ref25","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1016\/S1051-0443(91)72215-X","article-title":"Incomplete opening of LGM (Vena Tech) filters inserted via the transjugular approach","volume":"2","author":"R A Reed","year":"1991","journal-title":"J Vasc Interv Radiol"},{"issue":"04","key":"ref26","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/j.jvir.2007.11.024","article-title":"The VenaTech LP permanent caval filter: effectiveness and safety in the prevention of pulmonary embolism \u2013 a European multicenter study","volume":"19","author":"A F Le Blanche","year":"2008","journal-title":"J Vasc Interv Radiol"},{"issue":"02","key":"ref27","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s003300050382","article-title":"Long-term results of the Simon nitinol inferior vena cava filter","volume":"8","author":"P A Poletti","year":"1998","journal-title":"Eur Radiol"},{"issue":"01","key":"ref28","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1148\/radiology.216.1.r00jl1254","article-title":"Inferior vena caval filters: review of a 26-year single-center clinical experience","volume":"216","author":"C A Athanasoulis","year":"2000","journal-title":"Radiology"},{"issue":"11","key":"ref29","doi-asserted-by":"crossref","first-page":"759","DOI":"10.1016\/S0009-9260(99)91180-7","article-title":"Long-term follow-up of the Bird's Nest IVC filter","volume":"54","author":"A A Nicholson","year":"1999","journal-title":"Clin Radiol"},{"issue":"04","key":"ref30","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.jvir.2007.02.007","article-title":"Clinical comparison of two optional vena cava filters","volume":"18","author":"I S Keller","year":"2007","journal-title":"J Vasc Interv Radiol"},{"issue":"03","key":"ref31","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1583\/05-1741.1","article-title":"TrapEase vena cava filter: experience in 751 patients","volume":"13","author":"S P Kalva","year":"2006","journal-title":"J Endovasc Ther"},{"key":"ref32","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1016\/j.clinimag.2021.01.041","article-title":"Chronic inferior vena cava filter thrombosis presenting with low back pain and radiculopathy: treatment with thrombolysis, filter removal, and stenting","volume":"76","author":"G K Vilanilam","year":"2021","journal-title":"Clin Imaging"},{"issue":"05","key":"ref33","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1111\/j.1440-1673.2008.01969.x","article-title":"Retrievable Gunther Tulip inferior vena cava filter: experience in 317 patients","volume":"52","author":"M F Given","year":"2008","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"02","key":"ref34","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1055\/s-0036-1582121","article-title":"A critical review of available retrievable inferior vena cava filters and future directions","volume":"33","author":"J P Montgomery","year":"2016","journal-title":"Semin Intervent Radiol"},{"issue":"20","key":"ref35","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.1001\/archinternmed.2010.316","article-title":"Prevalence of fracture and fragment embolization of Bard retrievable vena cava filters and clinical implications including cardiac perforation and tamponade","volume":"170","author":"W Nicholson","year":"2010","journal-title":"Arch Intern Med"},{"issue":"10","key":"ref36","doi-asserted-by":"crossref","first-page":"1353","DOI":"10.1016\/j.jvir.2017.06.032","article-title":"Multicenter trial of the VenaTech convertible vena cava filter","volume":"28","author":"E J Hohenwalter","year":"2017","journal-title":"J Vasc Interv Radiol"},{"issue":"04","key":"ref37","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.jvir.2012.12.011","article-title":"Pilot study evaluating the safety of a combined central venous catheter and inferior vena cava filter in critically ill patients at high risk of pulmonary embolism","volume":"24","author":"C A Cadavid","year":"2013","journal-title":"J Vasc Interv Radiol"},{"issue":"03","key":"ref38","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1097\/TA.0000000000000756","article-title":"A new device for the prevention of pulmonary embolism in critically ill patients: results of the European Angel Catheter Registry","volume":"79","author":"F S Taccone","year":"2015","journal-title":"J Trauma Acute Care Surg"},{"issue":"08","key":"ref39","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.jvir.2012.05.039","article-title":"In vitro analysis of polymer candidates for the development of absorbable vascular filters","volume":"23","author":"M D Eggers","year":"2012","journal-title":"J Vasc Interv Radiol"},{"issue":"03","key":"ref40","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1007\/s11239-015-1278-3","article-title":"Preparation and experimental research into retrievable rapamycin- and heparin-coated vena cava filters: a pilot study","volume":"41","author":"H Zhao","year":"2016","journal-title":"J Thromb Thrombolysis"}],"container-title":["Seminars in Interventional Radiology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0042-1751294.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,31]],"date-time":"2022-08-31T22:37:47Z","timestamp":1661985467000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0042-1751294"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":40,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2022,8,31]]},"published-print":{"date-parts":[[2022,6]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0042-1751294","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0739-9529","1098-8963"],"issn-type":[{"value":"0739-9529","type":"print"},{"value":"1098-8963","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}