{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T19:49:57Z","timestamp":1740167397201,"version":"3.37.3"},"reference-count":26,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Wrist Surg"],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Objective\u2003We aimed to compare the functional and clinical results between our new repair technique in the groups with and without pronator quadratus (PQ) repair in distal radius fractures treated with plate fixation using the volar approach.<\/jats:p><jats:p>\n          Methods\u2003The medical records of patients who underwent open reduction and volar plate fixation due to distal radius fracture between 2018 and 2020 were studied. In group A, PQ cannot be sutured or tension may occur, the intact radial fascia of the deep anterior fascia (DAF) was placed under the flexors toward the PQ and it was sutured with a 3-0 slow-absorbable monofilament suture to DAF. In group B, no repair was performed. In group C, PQ was sutured with traditional method. Range of motion (ROM) of wrist and handgrip strengths were measured at final examination. Pain was assessed with Visual Analogue Score (VAS), and functional status was evaluated with Quick - Disabilities of the Arm, Shoulder, and Hand (DASH). Complications which included tendinopathy, neuritis, tendon rupture due to plate irritation, implant failure, and malunion were also compared.<\/jats:p><jats:p>\n          Results\u2003Seventy-seven patients (group A, 21, group B, 24, group C, 32 patients) were included in the final follow-up examination who met our inclusion criteria. Among the clinical, functional, and radiological results such as ROM, VAS, DASH, grip strength, and complications in the all group at a mean postoperative of 16.6 months no significant difference was observed.<\/jats:p><jats:p>\n          Conclusion\u2003Although there was no significant difference between the groups in this study, we think that covering the plate may prevent long-term complications.<\/jats:p>","DOI":"10.1055\/s-0043-1760734","type":"journal-article","created":{"date-parts":[[2023,1,21]],"date-time":"2023-01-21T00:13:25Z","timestamp":1674260005000},"page":"390-399","source":"Crossref","is-referenced-by-count":1,"title":["A New Repair Technique in Pronator Quadratus in Management of Distal Radius Fracture: Comparison with Primary Repair and Unrepaired Techniques"],"prefix":"10.1055","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3437-6394","authenticated-orcid":false,"given":"\u00d6mer","family":"Ayik","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serkan","family":"Bayram","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Murat","family":"Altan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic and Traumatology, Sarikami\u015f State Hospital, Kars, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muhammed \u00c7a\u011fatay","family":"Engin","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Faculty of Medicine, Ataturk University, Erzurum, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,1,20]]},"reference":[{"issue":"06","key":"ref1","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/S0266-7681(96)80175-6","article-title":"Pronator quadratus revisited","volume":"21","author":"P R Stuart","year":"1996","journal-title":"J Hand Surg [Br]"},{"issue":"03","key":"ref2","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1097\/01.bth.0000126570.82826.0a","article-title":"Volar fixed-angle fixation of distal radius fractures: the DVR plate","volume":"8","author":"J Orbay","year":"2004","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"05","key":"ref3","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/s00402-020-03365-y","article-title":"Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures","volume":"140","author":"M Leixnering","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"930","DOI":"10.1016\/S0363-5023(05)80139-X","article-title":"The stabilizing mechanism of the distal radioulnar joint during pronation and supination","volume":"20","author":"H Kihara","year":"1995","journal-title":"J Hand Surg Am"},{"issue":"09","key":"ref5","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.1016\/j.jhsa.2012.06.005","article-title":"Assessment of pronator quadratus repair integrity following volar plate fixation for distal radius fractures: a prospective clinical cohort study","volume":"37","author":"C R Swigart","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"03","key":"ref6","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1007\/s11751-017-0288-4","article-title":"Repair of the pronator quadratus after volar plate fixation in distal radius fractures: a systematic review","volume":"12","author":"M AM Mulders","year":"2017","journal-title":"Strateg Trauma Limb Reconstr"},{"issue":"08","key":"ref7","doi-asserted-by":"crossref","first-page":"1627","DOI":"10.1016\/j.otsr.2020.06.003","article-title":"Is pronator quadratus repair necessary to improve outcomes after volar plate fixation of distal radius fractures? A systematic review and meta-analysis","volume":"106","author":"F Shi","year":"2020","journal-title":"Orthop Traumatol Surg Res"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/BOT.0b013e3182539333","article-title":"The effects of pronator quadratus repair on outcomes after volar plating of distal radius fractures","volume":"27","author":"S H Hershman","year":"2013","journal-title":"J Orthop Trauma"},{"issue":"09","key":"ref9","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.1016\/j.jhsa.2013.06.006","article-title":"Prospective evaluation of pronator quadratus repair following volar plate fixation of distal radius fractures","volume":"38","author":"R Tosti","year":"2013","journal-title":"J Hand Surg Am"},{"issue":"06","key":"ref10","doi-asserted-by":"crossref","first-page":"369","DOI":"10.5435\/00124635-200906000-00005","article-title":"Complications of volar plate fixation for managing distal radius fractures","volume":"17","author":"L M Berglund","year":"2009","journal-title":"J Am Acad Orthop Surg"},{"issue":"05","key":"ref11","first-page":"1038","article-title":"Development of the QuickDASH: comparison of three item-reduction approaches","volume":"87","author":"D E Beaton","year":"2005","journal-title":"J Bone Joint Surg Am"},{"issue":"02","key":"ref12","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1177\/0300060513476438","article-title":"Complications following dorsal versus volar plate fixation of distal radius fracture: a meta-analysis","volume":"41","author":"J Wei","year":"2013","journal-title":"J Int Med Res"},{"issue":"04","key":"ref13","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1007\/s11552-009-9180-0","article-title":"Flexor tendon problems after volar plate fixation of distal radius fractures","volume":"4","author":"M N Adham","year":"2009","journal-title":"Hand (N Y)"},{"issue":"445","key":"ref14","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1097\/01.blo.0000205894.98361.29","article-title":"Effects of implant material and plate design on tendon function and morphology","volume":"445","author":"M S Cohen","year":"2006","journal-title":"Clin Orthop Relat Res"},{"issue":"01","key":"ref15","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/BTH.0b013e3180cac281","article-title":"Minimally invasive plate osteosynthesis of distal radius fractures using a pronator sparing approach","volume":"12","author":"M K Sen","year":"2008","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.main.2009.04.007","article-title":"Pr\u00e9servation du muscle carr\u00e9 pronateur dans les ost\u00e9osynth\u00e8ses des fractures de l'extr\u00e9mit\u00e9 distale du radius par plaque palmaire verrouill\u00e9e. Technique chirurgicale","volume":"28","author":"C Dos Remedios","year":"2009","journal-title":"Chir Main"},{"issue":"04","key":"ref17","first-page":"381","article-title":"R\u00e9paration du pronator quadratus par surjet aller-retour dans la voie de Henry: pronator quadratus repair using the Henry approach with an outward-return running suture","volume":"93","author":"L Erhard","year":"2007","journal-title":"Rev Chir Orthop Repar Appar Mot"},{"issue":"03","key":"ref18","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1055\/s-0035-1550040","article-title":"Abl\u00f6sung und Refixierung des M. pronator quadratus mit einem Teil des M. brachioradialis Ansatzes","volume":"47","author":"B Hohendorff","year":"2015","journal-title":"Handchirurgie\u00b7 Mikrochirurgie\u00b7 Plast Chir"},{"issue":"03","key":"ref19","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s11552-012-9420-6","article-title":"The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating","volume":"7","author":"Z S Ahsan","year":"2012","journal-title":"Hand (N Y)"},{"issue":"08","key":"ref20","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1080\/00325481.1988.11700310","article-title":"Layered closure of lacerations","volume":"83","author":"L G Phillips","year":"1988","journal-title":"Postgrad Med"},{"issue":"03","key":"ref21","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1007\/s00276-017-1947-3","article-title":"A cadaver study into the number of fasciotomies required to decompress the anterior compartment in forearm compartment syndrome","volume":"40","author":"L Benamran","year":"2018","journal-title":"Surg Radiol Anat"},{"issue":"12","key":"ref22","doi-asserted-by":"crossref","first-page":"2650","DOI":"10.1016\/j.injury.2017.10.010","article-title":"A systematic review of volar locking plate removal after distal radius fracture","volume":"48","author":"M Yamamoto","year":"2017","journal-title":"Injury"},{"issue":"03","key":"ref23","doi-asserted-by":"crossref","first-page":"278","DOI":"10.1177\/1558944715620792","article-title":"Hand surgeon reporting of tendon rupture following distal radius volar plating","volume":"11","author":"N A Monaco","year":"2016","journal-title":"Hand (N Y)"},{"issue":"02","key":"ref24","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1302\/0301-620X.80B2.0800225","article-title":"Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius","volume":"80","author":"J SP Bell","year":"1998","journal-title":"J Bone Joint Surg Br"},{"issue":"09","key":"ref25","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1016\/j.jhsa.2009.07.008","article-title":"Quantification of pronator quadratus contribution to isometric pronation torque of the forearm","volume":"34","author":"M O McConkey","year":"2009","journal-title":"J Hand Surg Am"},{"issue":"03","key":"ref26","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s00590-013-1193-2","article-title":"The pronator quadratus muscle after plating of distal radius fractures: is the muscle still working?","volume":"24","author":"M Armangil","year":"2014","journal-title":"Eur J Orthop Surg Traumatol"}],"container-title":["Journal of Wrist Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1760734.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,12]],"date-time":"2023-10-12T23:10:10Z","timestamp":1697152210000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1760734"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,20]]},"references-count":26,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2023,10,12]]},"published-print":{"date-parts":[[2023,10]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1760734","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2163-3916","2163-3924"],"issn-type":[{"type":"print","value":"2163-3916"},{"type":"electronic","value":"2163-3924"}],"subject":[],"published":{"date-parts":[[2023,1,20]]}}}