{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T22:15:12Z","timestamp":1787004912845,"version":"build-2736575974"},"reference-count":29,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Objective\u2003The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws [AO-3TLS] vs. two transarticular 7.0-mm headless cannulated multi-use compression screws [MUC-2TS]) in dynamic non-destructive testing and compression testing to failure.<\/jats:p>\n                  <jats:p>Study Design\u2003The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the remaining treatment. The dynamic test was performed alternating non-destructive compression tests at a displacement rate of 5\u2009mm\/min up to 5,000\u2009N and sinusoidal compressive cyclic tests at 6\u2009Hz, using a 3,600-N amplitude for 8,550 cycles. Construct stiffness and maximum sagittal plane rotation about the PIP joint markers were determined during the dynamic test. After the dynamic test reached 136,800 cycles, the monotonic compressive test until failure was performed on each construct: load, displacement and sagittal plane rotation about the PIP joint marker at failure were analysed.<\/jats:p>\n                  <jats:p>Results\u2003The evaluated biomechanical properties showed no statistical difference between the AO-3TLS and MUC-2TS treatment groups in any of the ramps of the dynamic non-destructive test and in the compression loading until failure test.<\/jats:p>\n                  <jats:p>Conclusion\u2003The MUC-2TS treatment produced biomechanical properties equivalent to the AO-3TLS treatment for PIP joint arthrodesis.<\/jats:p>","DOI":"10.1055\/s-0043-1761244","type":"journal-article","created":{"date-parts":[[2023,2,9]],"date-time":"2023-02-09T19:07:59Z","timestamp":1675969679000},"page":"184-192","source":"Crossref","is-referenced-by-count":2,"title":["Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws"],"prefix":"10.1055","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3860-5796","authenticated-orcid":false,"given":"Aires Santana","family":"Rumpel","sequence":"additional","affiliation":[{"name":"Department of Animal Medicine, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anderson Luiz","family":"De Carvalho","sequence":"additional","affiliation":[{"name":"Department of Animal Medicine, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8548-8935","authenticated-orcid":false,"given":"Jakson Manfredini","family":"Vassoler","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matheus Lothar","family":"Schmidt","sequence":"additional","affiliation":[{"name":"Post-Graduation Program in Mining, Metallurgical and Materials Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cleiton Costa","family":"Mertz","sequence":"additional","affiliation":[{"name":"Post-Graduation Program in Mining, Metallurgical and Materials Engineering, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cesar Augusto Camacho","family":"Rozo","sequence":"additional","affiliation":[{"name":"Universidad del Quind\u00edo, Armenia, Quind\u00edo, Colombia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanna Kulczynski","family":"Campos","sequence":"additional","affiliation":[{"name":"Department of Animal Medicine, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4081-4362","authenticated-orcid":false,"given":"Marcelo Meller","family":"Alievi","sequence":"additional","affiliation":[{"name":"Department of Animal Medicine, Federal University of Rio Grande do Sul, Porto Alegre, RS, Brazil"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2023,2,9]]},"reference":[{"key":"ref1","first-page":"281","volume-title":"Distal limb","author":"D D Frisbie","year":"2015"},{"issue":"04","key":"ref2","doi-asserted-by":"crossref","first-page":"303","DOI":"10.3415\/VCOT-08-03-0027","article-title":"A limited surgical approach for pastern arthrodesis in horses with severe osteoarthritis","volume":"22","author":"P Jones","year":"2009","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"03","key":"ref3","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.cveq.2005.07.004","article-title":"Arthrodesis techniques in horses","volume":"21","author":"C J Zubrod","year":"2005","journal-title":"Vet Clin North Am Equine Pract"},{"key":"ref4","first-page":"1374","volume-title":"Arthrodesis techniques","author":"C J Lischer","year":"2019"},{"key":"ref5","first-page":"277","volume-title":"Arthrodesis of the proximal interphalangeal joint","author":"J P Watkins","year":"2020"},{"issue":"10","key":"ref6","first-page":"1364","article-title":"Arthrodesis of the proximal interphalangeal joint in the horse: a surgical treatment for high ringbone","volume":"173","author":"J E Schneider","year":"1978","journal-title":"J Am Vet Med Assoc"},{"issue":"08","key":"ref7","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1111\/j.1532-950X.2007.00338.x","article-title":"In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion","volume":"36","author":"G A Sod","year":"2007","journal-title":"Vet Surg"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1053\/jvet.2002.29457","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two 7-hole 3.5-mm broad and two 5-hole 4.5-mm narrow dynamic compression plates","volume":"31","author":"B C Watt","year":"2002","journal-title":"Vet Surg"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"103252","DOI":"10.1016\/j.jevs.2020.103252","article-title":"Comparison of a 3-hole 4.5-mm dynamic compression plate and a 7-hole 5.5-mm Y locking compression plate for arthrodesis of the proximal interphalangeal joint in horses - an ex vivo biomechanical study","volume":"94","author":"C AS Latorre","year":"2020","journal-title":"J Equine Vet Sci"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1111\/j.1532-950X.1985.tb00869.x","article-title":"Holding power of orthopedic screws in equine third metacarpal and metatarsal bones","volume":"14","author":"J V Yovich","year":"1985","journal-title":"Vet Surg"},{"issue":"03","key":"ref11","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1053\/jvet.2001.23353","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws","volume":"30","author":"B C Watt","year":"2001","journal-title":"Vet Surg"},{"issue":"07","key":"ref12","doi-asserted-by":"crossref","first-page":"861","DOI":"10.1111\/j.1532-950X.2009.00574.x","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of two parallel headless, tapered, variable-pitched, titanium compression screws and two parallel 5.5\u2009mm stainless-steel cortical screws","volume":"38","author":"R R Wolker","year":"2009","journal-title":"Vet Surg"},{"issue":"03","key":"ref13","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1111\/j.1532-950X.2011.00817.x","article-title":"An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: two parallel transarticular headless tapered variable pitch screws versus two parallel transarticular AO cortical bone screws inserted in lag fashion","volume":"40","author":"T Gudehus","year":"2011","journal-title":"Vet Surg"},{"issue":"02","key":"ref14","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/j.1532-950X.2010.00792.x","article-title":"Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of 3-hole 4.5\u2009mm locking compression plate and 3-hole 4.5\u2009mm narrow dynamic compression plate, with two transarticular 5.5\u2009mm cortex screws","volume":"40","author":"A L Zoppa","year":"2011","journal-title":"Vet Surg"},{"issue":"05","key":"ref15","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1111\/j.1532-950X.2011.00830.x","article-title":"A mechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial locking compression plate and two abaxial transarticular cortical screws versus an axial dynamic compression plate and two abaxial transarticular cortical screws","volume":"40","author":"G A Sod","year":"2011","journal-title":"Vet Surg"},{"issue":"03","key":"ref16","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1111\/j.1532-950X.2013.01111.x","article-title":"In vitro biomechanical comparison of a 4.5\u2009mm narrow locking compression plate construct versus a 4.5\u2009mm limited contact dynamic compression plate construct for arthrodesis of the equine proximal interphalangeal joint","volume":"42","author":"B J Ahern","year":"2013","journal-title":"Vet Surg"},{"issue":"01","key":"ref17","first-page":"25","article-title":"Arthrodese des proximalen Interphalangealgelenks beim Pferd: biomechanischer Vergleich von 2 unterschiedlichen LCP-Systemen - Verwendung einer axialen Verriegelungsplatte und zweier abaxialer transartikul\u00e4rer Kortikalisschrauben","volume":"48","author":"A Vidovi\u0107","year":"2020","journal-title":"Tierarztl Prax Ausg G Grosstiere Nutztiere"},{"issue":"01","key":"ref18","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/j.1532-950X.2009.00615.x","article-title":"An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion","volume":"39","author":"G A Sod","year":"2010","journal-title":"Vet Surg"},{"issue":"02","key":"ref19","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1111\/j.1532-950X.2009.00627.x","article-title":"A technique for laser-facilitated equine pastern arthrodesis using parallel screws inserted in lag fashion","volume":"39","author":"A E Watts","year":"2010","journal-title":"Vet Surg"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1055\/s-0039-1677747","article-title":"A standing percutaneous technique for proximal interphalangeal joint arthrodesis in twelve horses (2014-2017)","volume":"32","author":"K Heaton","year":"2019","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref21","first-page":"221","volume-title":"Proximal interphalangeal arthrodesis: screw fixation","author":"J A Auer","year":"2000"},{"issue":"03","key":"ref22","doi-asserted-by":"crossref","first-page":"234","DOI":"10.2460\/ajvr.2000.61.234","article-title":"Limb loading activity of adult horses confined to box stalls in an equine hospital barn","volume":"61","author":"L A McDuffee","year":"2000","journal-title":"Am J Vet Res"},{"issue":"03","key":"ref23","first-page":"365","article-title":"A laboratory system for production of flexion rates and forces in the forelimb of the horse","volume":"39","author":"H B Kingsbury","year":"1978","journal-title":"Am J Vet Res"},{"issue":"03","key":"ref24","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1016\/j.jbiomech.2008.11.017","article-title":"Design and validation of a dynamometric horseshoe for the measurement of three-dimensional ground reaction force on a moving horse","volume":"42","author":"H Chateau","year":"2009","journal-title":"J Biomech"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"110888","DOI":"10.1016\/j.jbiomech.2021.110888","article-title":"In vitro motions of the medial and lateral proximal sesamoid bones under mid-stance load conditions are consistent with racehorse fracture configurations","volume":"130","author":"S K Shaffer","year":"2022","journal-title":"J Biomech"},{"key":"ref26","doi-asserted-by":"crossref","first-page":"110455","DOI":"10.1016\/j.jbiomech.2021.110455","article-title":"How does bone strain vary between the third metacarpal and the proximal phalangeal bones of the equine distal limb?","volume":"123","author":"E Singer","year":"2021","journal-title":"J Biomech"},{"issue":"09","key":"ref27","first-page":"E191","article-title":"Cannulated screw with solid core insert: stronger than cannulated screws","volume":"43","author":"J M Dundon","year":"2014","journal-title":"Am J Orthop"},{"issue":"06","key":"ref28","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1097\/00005131-200607000-00008","article-title":"Effects of surgical errors on small fragment screw fixation","volume":"20","author":"C Collinge","year":"2006","journal-title":"J Orthop Trauma"},{"issue":"02","key":"ref29","doi-asserted-by":"crossref","first-page":"116","DOI":"10.2460\/ajvr.81.2.116","article-title":"Assessment of two augmentation techniques on the mechanical properties of titanium cannulated bone screws","volume":"81","author":"P Y Mulon","year":"2020","journal-title":"Am J Vet Res"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1761244.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T11:46:19Z","timestamp":1730807179000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1761244"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,9]]},"references-count":29,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2023,7,17]]},"published-print":{"date-parts":[[2023,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1761244","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"value":"0932-0814","type":"print"},{"value":"2567-6911","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,9]]}}}