{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,7,1]],"date-time":"2024-07-01T03:08:21Z","timestamp":1719803301330},"reference-count":17,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2023,2,7]],"date-time":"2023-02-07T00:00:00Z","timestamp":1675728000000},"content-version":"vor","delay-in-days":6,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Plast Surg"],"published-print":{"date-parts":[[2023,2]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Background\u2003Orbital blowout fractures are peculiar injuries causing disruption of both ocular function and symmetry. We present our experience with the use of a precontoured titanium mesh in orbital blowout fractures.<\/jats:p><jats:p>\n          Methods\u2003A retrospective study of patients undergoing correction of orbital blowout fractures with a precontoured titanium mesh was done at a tertiary care center in Mumbai. Data regarding demographics and pre- and postoperative clinical and radiological attributes were retrieved and compared.<\/jats:p><jats:p>\n          Results\u2003A total of 21 patients (19 males and 2 females) underwent correction of blowout fractures with a precontoured titanium mesh. The follow-up period ranged from 6 to 10 months. Road traffic accident (76%) was the most common etiology. Twenty (95%) patients had impure blowout fractures and 1 (5%) patient had a pure blowout. The orbital floor was most commonly fractured (16 [76%]). Associated fractures of the zygomaticomaxillary complex were found in 71% of patients. All patients were operated on within 3 weeks of trauma. A comparison of the operated and uninjured sides on coronal views of computed tomography (CT) scan in nine patients by Photopea application revealed a correction of the increased cross-sectional area in all cases. Enophthalmos was completely corrected in 94% patients, while 92% patients had complete correction of diplopia. One patient with a comminuted zygomatic fracture had persistent diplopia and mild enophthalmos. Infraorbital paresthesia persisted in 58% patients at 6 months of follow-up. No significant postoperative complications were noted.<\/jats:p><jats:p>\n          Conclusion\u2003The precontoured titanium mesh restores orbital wall anatomy and is safe, quick, fairly easy, and reproducible with a shorter learning curve. With proper patient selection and execution, prefabricated titanium mesh can serve as an excellent reconstructive option in blowout fractures of the orbit.<\/jats:p>","DOI":"10.1055\/s-0043-1761597","type":"journal-article","created":{"date-parts":[[2023,2,8]],"date-time":"2023-02-08T00:17:50Z","timestamp":1675815470000},"page":"062-067","source":"Crossref","is-referenced-by-count":2,"title":["Outcome of Precontoured Titanium Mesh in the Reconstruction of Orbital Blowout Fractures"],"prefix":"10.1055","volume":"56","author":[{"given":"Amarnath","family":"Munoli","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Lokmanya Tilak Municipal Medical College and General Hospital, Mumbai, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinisha","family":"Bhanushali","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Lokmanya Tilak Municipal Medical College and General Hospital, Mumbai, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mukund","family":"Jagannathan","sequence":"additional","affiliation":[{"name":"Department of Plastic and Reconstructive Surgery, Lokmanya Tilak Municipal Medical College and General Hospital, Mumbai, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,2,7]]},"reference":[{"key":"ref2","first-page":"293","article-title":"Traumatic enophthalmos","volume":"41","author":"R L Pfeiffer","year":"1943","journal-title":"Trans Am Ophthalmol Soc"},{"issue":"05","key":"ref3","first-page":"100","article-title":"Orbital floor fractures: a reassessment of pathogenesis","volume":"75","author":"J J Phalen","year":"1990","journal-title":"Nebr Med J"},{"issue":"06","key":"ref4","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1016\/0002-9394(76)90774-1","article-title":"Blow-out fracture of the orbit; mechanism and correction of internal orbital fracture","volume":"44","author":"B Smith","year":"1957","journal-title":"Am J Ophthalmol"},{"issue":"09","key":"ref5","doi-asserted-by":"crossref","first-page":"1066","DOI":"10.1016\/S0161-6420(83)80049-9","article-title":"Surgery on orbital floor fractures. Influence of time of repair and fracture size","volume":"90","author":"M J Hawes","year":"1983","journal-title":"Ophthalmology"},{"issue":"06","key":"ref6","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.ijom.2021.10.001","article-title":"CT parameters in pure orbital wall fractures and their relevance in the choice of treatment and patient outcome: a systematic review","volume":"51","author":"M Wevers","year":"2022","journal-title":"Int J Oral Maxillofac Surg"},{"key":"ref7","author":"R H Douglas"},{"issue":"02","key":"ref8","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1097\/00006534-198602000-00004","article-title":"Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligament sling and its relation to intramuscular cone orbital fat","volume":"77","author":"P N Manson","year":"1986","journal-title":"Plast Reconstr Surg"},{"issue":"03","key":"ref10","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/01.sap.0000199173.73610.bc","article-title":"Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants","volume":"56","author":"S-B Nam","year":"2006","journal-title":"Ann Plast Surg"},{"issue":"04","key":"ref11","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1053\/joms.2003.50085","article-title":"Assessment of internal orbital reconstructions for pure blowout fractures: cranial bone grafts versus titanium mesh","volume":"61","author":"E Ellis III","year":"2003","journal-title":"J Oral Maxillofac Surg"},{"issue":"03","key":"ref12","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1016\/j.joms.2009.04.042","article-title":"Individual design and rapid prototyping in reconstruction of orbital wall defects","volume":"68","author":"W Tang","year":"2010","journal-title":"J Oral Maxillofac Surg"},{"issue":"06","key":"ref13","first-page":"12411","article-title":"Reconstruction of orbital blowout fractures using MEDPOR titanium mesh implants","volume":"9","author":"X Han","year":"2016","journal-title":"Int J Clin Exp Med"},{"issue":"03","key":"ref14","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/j.joms.2012.10.029","article-title":"Biomaterials for repair of orbital floor blowout fractures: a systematic review","volume":"71","author":"D R Gunarajah","year":"2013","journal-title":"J Oral Maxillofac Surg"},{"issue":"04","key":"ref15","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.coms.2012.07.002","article-title":"Biomaterials for reconstruction of the internal orbit","volume":"24","author":"J K Potter","year":"2012","journal-title":"Oral Maxillofac Surg Clin North Am"},{"issue":"01","key":"ref16","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1177\/1943387520939032","article-title":"Orbital implants in orbital fracture reconstruction: a ten-year series","volume":"14","author":"S Seen","year":"2021","journal-title":"Craniomaxillofac Trauma Reconstr"},{"issue":"04","key":"ref17","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/j.tripleo.2006.02.031","article-title":"Individual preformed titanium meshes for orbital fractures","volume":"102","author":"M C Metzger","year":"2006","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"10","key":"ref18","doi-asserted-by":"crossref","first-page":"1863","DOI":"10.1016\/j.ophtha.2006.03.062","article-title":"Anatomical 3-dimensional pre-bent titanium implant for orbital floor fractures","volume":"113","author":"M C Metzger","year":"2006","journal-title":"Ophthalmology"},{"issue":"02","key":"ref19","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1055\/s-0034-1395384","article-title":"A case series of rapid prototyping and intraoperative imaging in orbital reconstruction","volume":"8","author":"C G Lim","year":"2015","journal-title":"Craniomaxillofac Trauma Reconstr"}],"container-title":["Indian Journal of Plastic Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1761597.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,28]],"date-time":"2023-03-28T23:51:10Z","timestamp":1680047470000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1761597"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2]]},"references-count":17,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2023,3,28]]},"published-print":{"date-parts":[[2023,2]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1761597","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0970-0358","1998-376X"],"issn-type":[{"value":"0970-0358","type":"print"},{"value":"1998-376X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2]]}}}