{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T14:33:09Z","timestamp":1787668389095,"version":"build-2736575974"},"reference-count":9,"publisher":"Georg Thieme Verlag KG","issue":"01","license":[{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"vor","delay-in-days":60,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Surg J (N Y)"],"published-print":{"date-parts":[[2023,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Retained surgical foreign bodies are unanticipated events culminating from inadvertent operating room errors and may cause severe medical and legal problems between the patient and the doctor. Here, we report detecting a surgical instrument fragment 13 years after an open abdominal hysterectomy in a quadragenarian during her evaluation of a month-old complaint of lower abdominal and right thigh pain. A computed tomography scan of the abdomen demonstrated a radio-opaque linear foreign body traversing the right obturator foramen with extension into the pelvis cranially and the adductor compartment of the right thigh caudally. The metallic foreign body, identified as a fragmented handle of a uterine tenaculum forceps with a slender sharp-tip hook, could be removed laparoscopically from the pelvis after a diagnostic laparoscopy, preventing significant complications. The minimally invasive approach enabled a smooth recovery, and the patient could go home on the second postoperative day.<\/jats:p>","DOI":"10.1055\/s-0043-1764124","type":"journal-article","created":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T00:12:58Z","timestamp":1677802378000},"page":"e62-e66","source":"Crossref","is-referenced-by-count":7,"title":["Laparoscopic Retrieval of a 13-Year-Old Retained Iatrogenic Metallic Foreign Body from the Pelvis: An Uncommon Case Report"],"prefix":"10.1055","volume":"09","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9630-2932","authenticated-orcid":false,"given":"Deepak","family":"Rajput","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4847-4120","authenticated-orcid":false,"given":"Amit","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4588-3436","authenticated-orcid":false,"given":"Sruthi","family":"Shasheendran","sequence":"additional","affiliation":[{"name":"Department of General Surgery, University College of Medical Sciences, Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7746-4469","authenticated-orcid":false,"given":"Rishit","family":"Mani","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Patna, Bihar, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8466-7608","authenticated-orcid":false,"given":"Amoli","family":"Tandon","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0783-9998","authenticated-orcid":false,"given":"Shyam Karuppusamy","family":"Krishnasamy","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6106-2630","authenticated-orcid":false,"given":"Rohik Anjum T.","family":"Siddeek","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8187-7538","authenticated-orcid":false,"given":"Krishna Sai","family":"Bhukya","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4714-8868","authenticated-orcid":false,"given":"Sanketh","family":"Edem","sequence":"additional","affiliation":[{"name":"Department of General Surgery, All India Institute of Medical Sciences Rishikesh, Dehradun, Uttarakhand, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2023,3,2]]},"reference":[{"issue":"02","key":"ref2","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1097\/SLA.0b013e318181c9a3","article-title":"The frequency and significance of discrepancies in the surgical count","volume":"248","author":"C C Greenberg","year":"2008","journal-title":"Ann Surg"},{"issue":"05","key":"ref3","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1016\/j.legalmed.2005.04.004","article-title":"Medical and legal evaluations of the retained foreign bodies in Turkey","volume":"7","author":"A R Tumer","year":"2005","journal-title":"Leg Med (Tokyo)"},{"issue":"03","key":"ref4","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.jamcollsurg.2004.04.018","article-title":"Preventing sharps injuries in the operating room","volume":"199","author":"R Berguer","year":"2004","journal-title":"J Am Coll Surg"},{"issue":"03","key":"ref5","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1056\/NEJMsa021721","article-title":"Risk factors for retained instruments and sponges after surgery","volume":"348","author":"A A Gawande","year":"2003","journal-title":"N Engl J Med"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1016\/j.jss.2006.08.001","article-title":"Retained foreign bodies after surgery","volume":"138","author":"A E Lincourt","year":"2007","journal-title":"J Surg Res"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1016\/j.jamcollsurg.2012.06.014","article-title":"Effectiveness of a radiofrequency detection system as an adjunct to manual counting protocols for tracking surgical sponges: a prospective trial of 2,285 patients","volume":"215","author":"C C Rupp","year":"2012","journal-title":"J Am Coll Surg"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1590\/0100-69912016001004","article-title":"Unintentionally retained foreign bodies after surgical procedures. Analysis of 4547 cases","volume":"43","author":"D V Birolini","year":"2016","journal-title":"Rev Col Bras Cir"},{"issue":"05","key":"ref9","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1056\/NEJMsa0810119","article-title":"A surgical safety checklist to reduce morbidity and mortality in a global population","volume":"360","author":"A B Haynes","year":"2009","journal-title":"N Engl J Med"},{"issue":"04","key":"ref10","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1097\/SLA.0b013e3181656cd5","article-title":"Bar-coding surgical sponges to improve safety: a randomized controlled trial","volume":"247","author":"C C Greenberg","year":"2008","journal-title":"Ann Surg"}],"container-title":["The Surgery Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1764124.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,3]],"date-time":"2023-03-03T00:13:05Z","timestamp":1677802385000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1764124"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":9,"journal-issue":{"issue":"01","published-online":{"date-parts":[[2023,2,3]]},"published-print":{"date-parts":[[2023,1]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1764124","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2378-5128","2378-5136"],"issn-type":[{"value":"2378-5128","type":"print"},{"value":"2378-5136","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]}}}