{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T18:13:50Z","timestamp":1787163230039,"version":"build-2736575974"},"reference-count":27,"publisher":"Georg Thieme Verlag KG","issue":"06","license":[{"start":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T00:00:00Z","timestamp":1687910400000},"content-version":"vor","delay-in-days":27,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Arq Neuropsiquiatr"],"published-print":{"date-parts":[[2023,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Background\u2003The most frequent cause of death in neurosurgical patients is due to the increase in intracranial pressure (ICP); consequently, adequate monitoring of this parameter is extremely important.<\/jats:p>\n                  <jats:p>Objectives\u2003In this study, we aimed to analyze the accuracy of noninvasive measurement methods for intracranial hypertension (IH) in patients with traumatic brain injury (TBI).<\/jats:p>\n                  <jats:p>Methods\u2003The data were obtained from the PubMed database, using the following terms: intracranial\n          pressure, noninvasive, monitoring, assessment, and measurement. The selected articles date from 1980 to 2021, all of which were observational studies or clinical trials, in English and specifying ICP measurement in TBI. At the end of the selection, 21 articles were included in this review.<\/jats:p>\n                  <jats:p>Results\u2003The optic nerve sheath diameter (ONSD), pupillometry, transcranial doppler (TCD), multimodal combination, brain compliance using ICP waveform (ICPW), HeadSense, and Visual flash evoked pressure (FVEP) were analyzed. Pupillometry was not found to correlate with ICP, while HeadSense monitor and the FVEP method appear to have good correlation, but sensitivity and specificity data are not available. The ONSD and TCD methods showed good-to-moderate accuracy on invasive ICP values and potential to detect IH in most studies. Furthermore, multimodal combination may reduce the error possibility related to each technique. Finally, ICPW showed good accuracy to ICP values, but this analysis included TBI and non-TBI patients in the same sample.<\/jats:p>\n                  <jats:p>Conclusions\u2003Noninvasive ICP monitoring methods may be used in the near future to guide TBI patients' management.<\/jats:p>","DOI":"10.1055\/s-0043-1764411","type":"journal-article","created":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T18:52:42Z","timestamp":1687978362000},"page":"551-563","source":"Crossref","is-referenced-by-count":9,"title":["The use of noninvasive measurements of intracranial pressure in patients with traumatic brain injury: a narrative review"],"prefix":"10.1055","volume":"81","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3928-3573","authenticated-orcid":false,"given":"B\u00e1rbara Caroline Dias","family":"Faria","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6493-9939","authenticated-orcid":false,"given":"Luiz Gustavo Guimar\u00e3es","family":"Sacramento","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4593-2632","authenticated-orcid":false,"given":"Andr\u00e9 Vitor Rocha","family":"Queiroz","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7672-4238","authenticated-orcid":false,"given":"Fernanda de Andrade Dias","family":"Leite","sequence":"additional","affiliation":[{"name":"Faculdade de Ci\u00eancias M\u00e9dicas de Minas Gerais, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4217-5680","authenticated-orcid":false,"given":"Henrique Lacerda Lage Lopes de","family":"Oliveira","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4691-568X","authenticated-orcid":false,"given":"Thais Yuki","family":"Kimura","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7166-0645","authenticated-orcid":false,"given":"Rodrigo Moreira","family":"Faleiro","sequence":"additional","affiliation":[{"name":"Universidade Federal de Minas Gerais, Faculdade de Medicina, Belo Horizonte MG, Brazil."},{"name":"Faculdade de Ci\u00eancias M\u00e9dicas de Minas Gerais, Belo Horizonte MG, Brazil."},{"name":"Hospital Jo\u00e3o XXIII, Belo Horizonte MG, Brazil."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2023,6,28]]},"reference":[{"issue":"01","key":"ref1","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1016\/j.ajem.2016.09.044","article-title":"Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients","volume":"35","author":"M Raffiz","year":"2017","journal-title":"Am J Emerg Med"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.jss.2020.12.042","article-title":"Efficacy of Noninvasive Technologies in Triaging Traumatic Brain Injury and Correlating With Intracranial Pressure: A Prospective Study","volume":"262","author":"K E Singer","year":"2021","journal-title":"J Surg Res"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1007\/3-211-32318-X_73","article-title":"Innovative non-invasive method for absolute intracranial pressure measurement without calibration","volume":"95","author":"A Ragauskas","year":"2005","journal-title":"Acta Neurochir Suppl (Wien)"},{"issue":"03","key":"ref4","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1007\/s12028-011-9606-8","article-title":"Optic nerve ultrasound for the detection of raised intracranial pressure","volume":"15","author":"V Rajajee","year":"2011","journal-title":"Neurocrit Care"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/s13054-017-1632-2","article-title":"The accuracy of transcranial Doppler in excluding intracranial hypertension following acute brain injury: a multicenter prospective pilot study","volume":"21","author":"F A Rasulo","year":"2017","journal-title":"Crit Care"},{"issue":"07","key":"ref6","doi-asserted-by":"crossref","first-page":"e1002356","DOI":"10.1371\/journal.pmed.1002356","article-title":"Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study","volume":"14","author":"C Robba","year":"2017","journal-title":"PLoS Med"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1007\/3-211-32318-X_71","article-title":"Fuzzy pattern classification of hemodynamic data can be used to determine noninvasive intracranial pressure","volume":"95","author":"B Schmidt","year":"2005","journal-title":"Acta Neurochir Suppl (Wien)"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1161\/01.STR.0000047849.01376.AE","article-title":"Adaptive noninvasive assessment of intracranial pressure and cerebral autoregulation","volume":"34","author":"B Schmidt","year":"2003","journal-title":"Stroke"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"R67","DOI":"10.1186\/cc6897","article-title":"Optic nerve sonography in the diagnostic evaluation of adult brain injury","volume":"12","author":"T Soldatos","year":"2008","journal-title":"Crit Care"},{"issue":"08","key":"ref10","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1080\/02699052.2019.1605621","article-title":"Optical pupillometry in traumatic brain injury: neurological pupil index and its relationship with intracranial pressure through significant event analysis","volume":"33","author":"A R Stevens","year":"2019","journal-title":"Brain Inj"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/3-211-32318-X_72","article-title":"Clinical experience with the noninvasive ICP monitoring system","volume":"95","author":"Y L Zhao","year":"2005","journal-title":"Acta Neurochir Suppl (Wien)"},{"issue":"03","key":"ref12","doi-asserted-by":"crossref","first-page":"743","DOI":"10.3171\/2014.10.JNS141197","article-title":"Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure","volume":"123","author":"I M Maissan","year":"2015","journal-title":"J Neurosurg"},{"issue":"02","key":"ref13","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1016\/j.jss.2011.03.009","article-title":"Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma","volume":"170","author":"A Strumwasser","year":"2011","journal-title":"J Surg Res"},{"issue":"01","key":"ref14","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1186\/s13054-020-03105-z","article-title":"Multimodal non-invasive assessment of intracranial hypertension: an observational study","volume":"24","author":"C Robba","year":"2020","journal-title":"Crit Care"},{"issue":"05","key":"ref15","doi-asserted-by":"crossref","first-page":"437","DOI":"10.1590\/0004-282x-anp-2020-0300","article-title":"Noninvasive intracranial pressure monitoring methods: a critical review","volume":"79","author":"F M Moraes","year":"2021","journal-title":"Arq Neuropsiquiatr"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1097\/ANA.0000000000000622","article-title":"Noninvasive Intracranial Pressure Estimation With Transcranial Doppler: A Prospective Observational Study","volume":"32","author":"D Cardim","year":"2020","journal-title":"J Neurosurg Anesthesiol"},{"issue":"08","key":"ref17","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1089\/neu.2015.4134","article-title":"Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods","volume":"33","author":"D Cardim","year":"2016","journal-title":"J Neurotrauma"},{"issue":"05","key":"ref18","doi-asserted-by":"crossref","first-page":"802","DOI":"10.3171\/jns.1998.88.5.0802","article-title":"Cerebral perfusion pressure in head-injured patients: a noninvasive assessment using transcranial Doppler ultrasonography","volume":"88","author":"M Czosnyka","year":"1998","journal-title":"J Neurosurg"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/BF02188774","article-title":"Bedside measurement of the third ventricle's diameter during episodes of arising intracranial pressure after head trauma. Using transcranial real-time sonography for a non-invasive examination of intracranial compensation mechanisms","volume":"137","author":"K Mursch","year":"1995","journal-title":"Acta Neurochir (Wien)"},{"issue":"12","key":"ref20","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1007\/BF01727619","article-title":"Intracranial flow patterns at increasing intracranial pressure","volume":"65","author":"J Klingelh\u00f6fer","year":"1987","journal-title":"Klin Wochenschr"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.wneu.2017.07.022","article-title":"Prospective Evaluation of Noninvasive HeadSense Intracranial Pressure Monitor in Traumatic Brain Injury Patients Undergoing Invasive Intracranial Pressure Monitoring","volume":"106","author":"M W Herklots","year":"2017","journal-title":"World Neurosurg"},{"issue":"03","key":"ref22","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1007\/s00701-015-2672-5","article-title":"Intracranial pressure wave morphological classification: automated analysis and clinical validation","volume":"158","author":"C G Nucci","year":"2016","journal-title":"Acta Neurochir (Wien)"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1007\/978-3-7091-0956-4_21","article-title":"The new ICP minimally invasive method shows that the Monro-Kellie doctrine is not valid","volume":"114","author":"S Mascarenhas","year":"2012","journal-title":"Acta Neurochir Suppl (Wien)"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/978-3-319-22533-3_18","article-title":"Validation of a New Noninvasive Intracranial Pressure Monitoring Method by Direct Comparison with an Invasive Technique","volume":"122","author":"B Cabella","year":"2016","journal-title":"Acta Neurochir Suppl (Wien)"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/978-3-319-65798-1_16","article-title":"Analysis of a Minimally Invasive Intracranial Pressure Signals During Infusion at the Subarachnoid Spinal Space of Pigs","volume":"126","author":"G Frigieri","year":"2018","journal-title":"Acta Neurochir Suppl (Wien)"},{"issue":"12","key":"ref26","doi-asserted-by":"crossref","first-page":"1302","DOI":"10.3390\/jpm11121302","article-title":"A Novel Noninvasive Technique for Intracranial Pressure Waveform Monitoring in Critical Care","volume":"11","author":"S Brasil","year":"2021","journal-title":"J Pers Med"},{"key":"ref27","first-page":"123","article-title":"Research on simulation and experiment of noninvasive intracranial pressure monitoring based on acoustoelasticity effects","volume":"6","author":"J Wu","year":"2013","journal-title":"Med Devices (Auckl)"}],"container-title":["Arquivos de Neuro-Psiquiatria"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1764411.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,28]],"date-time":"2023-06-28T18:53:33Z","timestamp":1687978413000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1764411"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6]]},"references-count":27,"journal-issue":{"issue":"06","published-online":{"date-parts":[[2023,6,28]]},"published-print":{"date-parts":[[2023,6]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1764411","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0004-282X","1678-4227"],"issn-type":[{"value":"0004-282X","type":"print"},{"value":"1678-4227","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6]]}}}