{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T01:47:46Z","timestamp":1773280066829,"version":"3.50.1"},"reference-count":61,"publisher":"Georg Thieme Verlag KG","issue":"02","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Neurol Surg A Cent Eur Neurosurg"],"published-print":{"date-parts":[[2024,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Cervical laminoplasty is an increasingly popular surgical option for the treatment of cervical spondylotic myelopathy (CSM) and ossification of the posterior longitudinal ligament (OPLL). Over the past few decades, there have been substantial developments in both surgical technique and hardware options. As the field of cervical surgery rapidly evolves, there is a timely need to reassess the evolving complications associated with newer techniques. This review aims to synthesize the available literature on cervical laminoplasty and associated mechanical complications pertaining to different laminoplasty hinge fixation options.<\/jats:p>","DOI":"10.1055\/s-0043-1769005","type":"journal-article","created":{"date-parts":[[2023,7,28]],"date-time":"2023-07-28T22:52:47Z","timestamp":1690584767000},"page":"171-181","source":"Crossref","is-referenced-by-count":7,"title":["Laminoplasty in Motion: Evolving Techniques and Complications"],"prefix":"10.1055","volume":"85","author":[{"given":"Ian M.","family":"Singleton","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7810-3075","authenticated-orcid":false,"given":"Amit S.","family":"Piple","sequence":"additional","affiliation":[{"name":"The Taylor Collaboration, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ben","family":"Crawford","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashish","family":"Mittal","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander A.","family":"Rosinski","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dimitriy G.","family":"Kondrashov","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, St. Mary's Medical Center, San Francisco, California, United States"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2023,7,28]]},"reference":[{"issue":"12","key":"ref1","doi-asserted-by":"crossref","first-page":"E675","DOI":"10.1097\/BRS.0000000000000913","article-title":"Degenerative cervical myelopathy: epidemiology, genetics, and pathogenesis","volume":"40","author":"A Nouri","year":"2015","journal-title":"Spine"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"k186","DOI":"10.1136\/bmj.k186","article-title":"Degenerative cervical myelopathy","volume":"360","author":"B M Davies","year":"2018","journal-title":"BMJ"},{"issue":"S 02","key":"ref3","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1007\/s00586-013-2781-x","article-title":"Prevalence of cervical spondylotic myelopathy","volume":"24","author":"H D Boogaarts","year":"2015","journal-title":"Eur Spine J"},{"issue":"10","key":"ref4","doi-asserted-by":"crossref","first-page":"942","DOI":"10.1001\/jama.2021.1233","article-title":"Effect of ventral vs dorsal spinal surgery on patient-reported physical functioning in patients with cervical spondylotic myelopathy: a randomized clinical trial","volume":"325","author":"Z Ghogawala","year":"2021","journal-title":"JAMA"},{"issue":"07","key":"ref5","doi-asserted-by":"crossref","first-page":"e142","DOI":"10.5435\/JAAOS-D-16-00242","article-title":"Cervical laminoplasty: indications, surgical considerations, and clinical outcomes","volume":"26","author":"S K Cho","year":"2018","journal-title":"J Am Acad Orthop Surg"},{"issue":"05","key":"ref6","doi-asserted-by":"crossref","first-page":"508","DOI":"10.3171\/2017.4.SPINE16831","article-title":"Laminoplasty versus laminectomy with posterior spinal fusion for multilevel cervical spondylotic myelopathy: influence of cervical alignment on outcomes","volume":"27","author":"D Lau","year":"2017","journal-title":"J Neurosurg Spine"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"307916","DOI":"10.1155\/2012\/307916","article-title":"Laminoplasty techniques for the treatment of multilevel cervical stenosis","volume":"2012","author":"L K Mitsunaga","year":"2012","journal-title":"Adv Orthop"},{"issue":"04","key":"ref8","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s00590-002-0050-5","article-title":"New double-door laminoplasty procedures to preserve the muscular attachments to the spinous processes including the axis","volume":"12","author":"T Shiraishi","year":"2002","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"06","key":"ref9","first-page":"595","article-title":"Application of partial laminectomy in neck-shoulder-hand syndrome","volume":"38","author":"Y Kirita","year":"1964","journal-title":"Nihon Seikeigeka Gakkai Zasshi"},{"issue":"07","key":"ref10","doi-asserted-by":"crossref","first-page":"529","DOI":"10.2176\/nmc.ra.2014-0387","article-title":"Cervical laminoplasty: the history and the future","volume":"55","author":"R Kurokawa","year":"2015","journal-title":"Neurol Med Chir (Tokyo)"},{"key":"ref11","first-page":"792","article-title":"A new method of posterior decompression","volume":"16","author":"M Oyama","year":"1973","journal-title":"Chubuseisaisi"},{"key":"ref12","first-page":"483","article-title":"Double-door laminoplasty through longitudinal splitting of the spinous process for cervical spondylotic myelopathy","volume":"19","author":"T Kurokawa","year":"1984","journal-title":"Rinsho Seikei Geka"},{"issue":"07","key":"ref13","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1097\/00007632-198310000-00003","article-title":"Expansive open-door laminoplasty for cervical spinal stenotic myelopathy","volume":"8","author":"K Hirabayashi","year":"1983","journal-title":"Spine"},{"issue":"03","key":"ref14","doi-asserted-by":"crossref","first-page":"379","DOI":"10.14245\/ns.1938272.136","article-title":"A review of my invention of expansive laminoplasty","volume":"16","author":"K Hirabayashi","year":"2019","journal-title":"Neurospine"},{"issue":"01","key":"ref15","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/s00064-017-0527-3","article-title":"Open-door laminoplasty : what can the unilateral approach offer?","volume":"30","author":"R Kothe","year":"2018","journal-title":"Oper Orthop Traumatol"},{"issue":"02","key":"ref16","doi-asserted-by":"crossref","first-page":"154","DOI":"10.22603\/ssrr.2017-0061","article-title":"Recent surgical methods of double-door laminoplasty of the cervical spine (Kurokawa's method)","volume":"2","author":"S Hirabayashi","year":"2018","journal-title":"Spine Surg Relat Res"},{"issue":"09","key":"ref17","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1097\/BSD.0000000000000323","article-title":"Double-door or \u201cFrench-door\u201d cervical laminoplasty","volume":"28","author":"T S Protopsaltis","year":"2015","journal-title":"J Spinal Disord Tech"},{"key":"ref18","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/s13018-015-0151-6","article-title":"Cervical open-door laminoplasty technique with simple sutures and bone grafts: a single institutional study with 30 consecutive cases","volume":"10","author":"X K Li","year":"2015","journal-title":"J Orthop Surg Res"},{"issue":"06","key":"ref19","doi-asserted-by":"crossref","first-page":"530","DOI":"10.3171\/SPI.2008.4.08176","article-title":"Risk factors for closure of lamina after open-door laminoplasty","volume":"9","author":"M Matsumoto","year":"2008","journal-title":"J Neurosurg Spine"},{"issue":"01","key":"ref20","first-page":"e71","article-title":"Laminar reclosure after single open-door laminoplasty using titanium miniplates versus suture anchors","volume":"37","author":"W Hu","year":"2014","journal-title":"Orthopedics"},{"issue":"09","key":"ref21","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1016\/j.spinee.2011.07.026","article-title":"\u201cSpring-back\u201d closure associated with open-door cervical laminoplasty","volume":"11","author":"H Q Wang","year":"2011","journal-title":"Spine J"},{"issue":"01","key":"ref22","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1097\/01.bsd.0000211229.81930.80","article-title":"Use of small suture anchors in cervical laminoplasty to maintain canal expansion: a technical note","volume":"20","author":"J Y Lee","year":"2007","journal-title":"J Spinal Disord Tech"},{"issue":"04","key":"ref23","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s00586-016-4666-2","article-title":"Double-door cervical laminoplasty with suture anchors: evaluation of the clinical performance of the constructs","volume":"26","author":"T Fujishiro","year":"2017","journal-title":"Eur Spine J"},{"issue":"01","key":"ref24","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1080\/17453670710014770","article-title":"Open-door laminoplasty for multilevel cervical spondylotic myelopathy: good outcome in 12 patients using suture anchor fixation","volume":"79","author":"S C Yang","year":"2008","journal-title":"Acta Orthop"},{"issue":"08","key":"ref25","first-page":"400","article-title":"Using suture anchors for cervical laminoplasty: a reliable, safe, and simple technique","volume":"37","author":"S N Khan","year":"2008","journal-title":"Am J Orthop"},{"issue":"21","key":"ref26","doi-asserted-by":"crossref","first-page":"E1248","DOI":"10.1097\/BRS.0000000000000522","article-title":"Biomechanical evaluation of the suture anchors used in open-door laminoplasty: a cadaveric study","volume":"39","author":"Y Kurokawa","year":"2014","journal-title":"Spine"},{"issue":"10","key":"ref27","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00586-010-1419-5","article-title":"Laminoplasty using Twinfix suture anchors to maintain cervical canal expansion","volume":"19","author":"H L Yu","year":"2010","journal-title":"Eur Spine J"},{"issue":"08","key":"ref28","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1097\/BSD.0b013e31815cb1ba","article-title":"Double-door cervical laminoplasty with the use of suture anchors: technical note","volume":"21","author":"M Miyata","year":"2008","journal-title":"J Spinal Disord Tech"},{"issue":"03","key":"ref29","doi-asserted-by":"crossref","first-page":"188","DOI":"10.14245\/kjs.2014.11.3.188","article-title":"Modified open-door laminoplasty using hydroxyapatite spacers and miniplates","volume":"11","author":"S W Jin","year":"2014","journal-title":"Korean J Spine"},{"issue":"03","key":"ref30","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/01.BRS.0000042246.09816.20","article-title":"Biomechanical evaluation of cervical double-door laminoplasty using hydroxyapatite spacer","volume":"28","author":"S Kubo","year":"2003","journal-title":"Spine"},{"issue":"06","key":"ref31","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.31616\/asj.2018.12.6.1078","article-title":"Novel hybrid hydroxyapatite spacers ensure sufficient bone bonding in cervical laminoplasty","volume":"12","author":"N Tanaka","year":"2018","journal-title":"Asian Spine J"},{"issue":"09","key":"ref32","doi-asserted-by":"crossref","first-page":"1560","DOI":"10.1007\/s00586-011-1724-7","article-title":"Long-term results of double-door laminoplasty using hydroxyapatite spacers in patients with compressive cervical myelopathy","volume":"20","author":"A Kimura","year":"2011","journal-title":"Eur Spine J"},{"key":"ref33","first-page":"22","article-title":"Bilateral open-door cervical expansive laminoplasty with hydroxyapatite spacers and titanium screws","volume":"96","author":"M Takayasu","year":"2002","journal-title":"J Neurosurg"},{"issue":"02","key":"ref34","doi-asserted-by":"crossref","first-page":"60","DOI":"10.13004\/kjnt.2014.10.2.60","article-title":"Midline splitting cervical laminoplasty using allogeneic bone spacers: comparison of fusion rates between cervical spondylotic myelopathy and ossification of posterior longitudinal ligament","volume":"10","author":"J J Sheen","year":"2014","journal-title":"Korean J Neurotrauma"},{"issue":"05","key":"ref35","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3171\/2021.1.SPINE201633","article-title":"Open-door laminoplasty with stand-alone autologous bone spacers: evaluation of enlarged laminar arch with CT-multiplanar reconstruction","volume":"35","author":"H Kono","year":"2021","journal-title":"J Neurosurg Spine"},{"issue":"08","key":"ref36","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1097\/BSD.0b013e31815c85bd","article-title":"Expansive laminoplasty for cervical myelopathy with interconnected porous calcium hydroxyapatite ceramic spacers: comparison with autogenous bone spacers","volume":"21","author":"N Tanaka","year":"2008","journal-title":"J Spinal Disord Tech"},{"key":"ref37","first-page":"371","article-title":"Comparison of bone bonding between spinous process-splitting laminoplasty and en-bloc laminoplasty using hydroxyapatite spacers in cervical spine: minimum 2 years follow-up","volume":"18","author":"K Sasai","year":"2007","journal-title":"J Japan Spine Res Society"},{"issue":"06","key":"ref38","doi-asserted-by":"crossref","first-page":"551","DOI":"10.3171\/2009.2.17680","article-title":"Postoperative displacement of hydroxyapatite spacers implanted during double-door laminoplasty","volume":"10","author":"T Kaito","year":"2009","journal-title":"J Neurosurg Spine"},{"issue":"02","key":"ref39","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3171\/SPI\/2008\/8\/2\/121","article-title":"Delayed dural laceration by hydroxyapatite spacer causing tetraparesis following double-door laminoplasty","volume":"8","author":"A Kanemura","year":"2008","journal-title":"J Neurosurg Spine"},{"issue":"01","key":"ref40","doi-asserted-by":"crossref","first-page":"104","DOI":"10.3171\/SPI\/2008\/9\/7\/104","article-title":"Dural laceration","volume":"9","author":"R D Dickerman","year":"2008","journal-title":"J Neurosurg Spine"},{"issue":"01","key":"ref41","doi-asserted-by":"crossref","first-page":"e1080","DOI":"10.1002\/jsp2.1080","article-title":"Improved bone bonding of hydroxyapatite spacers with a high porosity in a quantitative computed tomography-image pixel analysis: a prospective 1-year comparative study of the consecutive cohort undergoing double-door cervical laminoplasty","volume":"3","author":"Y Takeoka","year":"2020","journal-title":"JOR Spine"},{"key":"ref42","first-page":"137","article-title":"Cervical laminoplasty: evaluation of bone bonding of a high porosity hydroxyapatite spacer","volume":"98","author":"T Iguchi","year":"2003","journal-title":"J Neurosurg"},{"issue":"04","key":"ref43","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1097\/00007632-199602150-00012","article-title":"A novel technique for laminoplasty augmentation of spinal canal area using titanium miniplate stabilization. A computerized morphometric analysis","volume":"21","author":"M F O'Brien","year":"1996","journal-title":"Spine"},{"issue":"05","key":"ref44","doi-asserted-by":"crossref","first-page":"e6026","DOI":"10.1097\/MD.0000000000006026","article-title":"Mini-plate fixation versus suture suspensory fixation in cervical laminoplasty: a meta-analysis","volume":"96","author":"F Y Liu","year":"2017","journal-title":"Medicine (Baltimore)"},{"issue":"04","key":"ref45","doi-asserted-by":"crossref","first-page":"E177","DOI":"10.1097\/BSD.0000000000000790","article-title":"plate fixation of expansive open-door laminoplasty decreases the incidence of postoperative C5 palsy","volume":"32","author":"Y Kobayashi","year":"2019","journal-title":"Clin Spine Surg"},{"issue":"49","key":"ref46","doi-asserted-by":"crossref","first-page":"e13534","DOI":"10.1097\/MD.0000000000013534","article-title":"Comparison of anchor screw fixation versus mini-plate fixation in unilateral expansive open-door laminoplasty for the treatment of multi-level cervical spondylotic myelopathy","volume":"97","author":"X Lin","year":"2018","journal-title":"Medicine (Baltimore)"},{"issue":"04","key":"ref47","doi-asserted-by":"crossref","first-page":"462","DOI":"10.14444\/7061","article-title":"Effect of titanium miniplate fixation on hinge fracture and hinge fracture displacement following cervical open-door laminoplasty","volume":"14","author":"D Shrestha","year":"2020","journal-title":"Int J Spine Surg"},{"issue":"01","key":"ref48","doi-asserted-by":"crossref","first-page":"53","DOI":"10.4184\/asj.2007.1.1.53","article-title":"New cervical laminoplasty polyethererketone cage: two case reports","volume":"1","author":"J Y Chung","year":"2007","journal-title":"Asian Spine J"},{"issue":"01","key":"ref49","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/BRS.0b013e3181fea49c","article-title":"Plate-only open door laminoplasty maintains stable spinal canal expansion with high rates of hinge union and no plate failures","volume":"36","author":"J M Rhee","year":"2011","journal-title":"Spine"},{"issue":"07","key":"ref50","doi-asserted-by":"crossref","first-page":"870","DOI":"10.1097\/00007632-198807000-00032","article-title":"Operative procedure and results of expansive open-door laminoplasty","volume":"13","author":"K Hirabayashi","year":"1988","journal-title":"Spine"},{"issue":"05","key":"ref51","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/00007632-199403000-00003","article-title":"Long-term follow-up studies of open-door expansive laminoplasty for cervical stenotic myelopathy","volume":"19","author":"K Satomi","year":"1994","journal-title":"Spine"},{"key":"ref52","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.jocn.2017.04.037","article-title":"Clinical and radiographic outcomes following hinge fracture during open-door cervical laminoplasty","volume":"43","author":"D H Lee","year":"2017","journal-title":"J Clin Neurosci"},{"issue":"02","key":"ref53","doi-asserted-by":"crossref","first-page":"45","DOI":"10.14245\/kjs.2014.11.2.45","article-title":"Hinge fracture during cervical open-door laminoplasty: does it affect clinical and radiographic outcomes?","volume":"11","author":"S H Cho","year":"2014","journal-title":"Korean J Spine"},{"issue":"04","key":"ref54","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3340\/jkns.2016.59.4.368","article-title":"Risk factors for delayed hinge fracture after plate-augmented cervical open-door laminoplasty","volume":"59","author":"J W Hur","year":"2016","journal-title":"J Korean Neurosurg Soc"},{"key":"ref55","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.wneu.2019.11.074","article-title":"Motion preservation at all costs? Multilevel hinge nonunion, plate breakage, and intradural plate migration after cervical laminoplasty: a case report and literature review","volume":"135","author":"A Rosinski","year":"2020","journal-title":"World Neurosurg"},{"issue":"02","key":"ref56","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s10195-016-0440-9","article-title":"Clinical outcome and safety study of a newly developed instrumented French-door cervical laminoplasty technique","volume":"18","author":"L A Nasto","year":"2017","journal-title":"J Orthop Traumatol"},{"issue":"07","key":"ref57","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1097\/BSD.0b013e3182024c06","article-title":"Lateral mass screw complications: analysis of 1662 screws","volume":"24","author":"P Katonis","year":"2011","journal-title":"J Spinal Disord Tech"},{"issue":"06","key":"ref58","doi-asserted-by":"crossref","first-page":"849","DOI":"10.4184\/asj.2015.9.6.849","article-title":"Screw back-out following \u201copen-door\u201d cervical laminoplasty: a review of 165 plates","volume":"9","author":"G Liu","year":"2015","journal-title":"Asian Spine J"},{"issue":"38","key":"ref59","doi-asserted-by":"crossref","first-page":"e4666","DOI":"10.1097\/MD.0000000000004666","article-title":"Facet joint disturbance induced by miniscrews in plated cervical laminoplasty: dose it influence the clinical and radiologic outcomes?","volume":"95","author":"H Chen","year":"2016","journal-title":"Medicine (Baltimore)"},{"issue":"04","key":"ref60","doi-asserted-by":"crossref","first-page":"1140","DOI":"10.1007\/s00586-016-4785-9","article-title":"Optimal area of lateral mass mini-screws implanted in plated cervical laminoplasty: a radiography anatomy study","volume":"26","author":"H Chen","year":"2017","journal-title":"Eur Spine J"},{"issue":"11","key":"ref61","first-page":"1324","article-title":"Effect of penetration of mini-plate lateral mass screws into facet joint on axial symptoms in cervical laminoplasty","volume":"27","author":"H Chen","year":"2013","journal-title":"Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi"}],"container-title":["Journal of Neurological Surgery Part A: Central European Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1769005.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T10:45:40Z","timestamp":1730803540000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1769005"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,28]]},"references-count":61,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2024,1,31]]},"published-print":{"date-parts":[[2024,3]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1769005","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2193-6315","2193-6323"],"issn-type":[{"value":"2193-6315","type":"print"},{"value":"2193-6323","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,28]]}}}