{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T15:23:57Z","timestamp":1748359437216},"reference-count":40,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Hand and Microsurgery"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1055\/s-0043-1769091","type":"journal-article","created":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T23:06:08Z","timestamp":1685747168000},"page":"100040","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["Comparative Finite Element (FE) Analysis of the Mechanical Behavior in an Innovative Nitinol Staple for Arthrodesis in Distal Interphalangeal Joint"],"prefix":"10.1016","volume":"16","author":[{"given":"V.","family":"Filardi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"R.","family":"Vaishya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1055\/s-0043-1769091_bib1","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/j.rehab.2016.01.006","article-title":"Risk factors and burden of osteoarthritis","volume":"59","author":"Palazzo","year":"2016","journal-title":"Ann Phys Rehabil Med"},{"issue":"10","key":"10.1055\/s-0043-1769091_bib2","doi-asserted-by":"crossref","first-page":"1382","DOI":"10.1002\/acr.20298","article-title":"A longitudinal study to explain the pain-depression link in older adults with osteoarthritis","volume":"63","author":"Hawker","year":"2011","journal-title":"Arthritis Care Res (Hoboken)"},{"key":"10.1055\/s-0043-1769091_bib3","doi-asserted-by":"crossref","first-page":"185","DOI":"10.1093\/bmb\/lds038","article-title":"Epidemiology and burden of osteoarthritis","volume":"105","author":"Litwic","year":"2013","journal-title":"Br Med Bull"},{"key":"10.1055\/s-0043-1769091_bib4","series-title":"Green\u2019s Operative Hand Surgery, 2 volume set","first-page":"345","article-title":"Treatment of the osteoarthritic hand and thumb","author":"Murray","year":"2016"},{"issue":"9","key":"10.1055\/s-0043-1769091_bib5","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1177\/17531934221111641","article-title":"Risk factors in distal interphalangeal joint arthrodesis in the hand: a retrospective study of 173 cases","volume":"47","author":"Runkel","year":"2022","journal-title":"J Hand Surg Eur Vol"},{"issue":"2","key":"10.1055\/s-0043-1769091_bib6","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1007\/s12593-014-0163-1","article-title":"A systematic review of distal interphalangeal joint arthrodesis","volume":"6","author":"Dickson","year":"2014","journal-title":"J Hand Microsurg"},{"issue":"7","key":"10.1055\/s-0043-1769091_bib7","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1016\/j.jhsa.2012.02.048","article-title":"Distal interphalangeal joint arthrodesis for degenerative osteoarthritis with compression screw: results in 102 digits","volume":"37","author":"Villani","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"7","key":"10.1055\/s-0043-1769091_bib8","doi-asserted-by":"crossref","first-page":"1408","DOI":"10.1016\/j.jhsa.2013.04.018","article-title":"Revision of failed distal interphalangeal arthrodesis complicated by retained headless screw","volume":"38","author":"Owusu","year":"2013","journal-title":"J Hand Surg Am"},{"issue":"6","key":"10.1055\/s-0043-1769091_bib9","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1302\/2058-5241.4.180042","article-title":"The proximal interphalangeal joint: arthritis and deformity","volume":"4","author":"Herren","year":"2019","journal-title":"EFORT Open Rev"},{"issue":"4","key":"10.1055\/s-0043-1769091_bib10","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1016\/j.jhsa.2014.11.026","article-title":"Management of osteoarthrosis of the thumb joints","volume":"40","author":"Berger","year":"2015","journal-title":"J Hand Surg Am"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib11","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.jhsa.2005.09.009","article-title":"Use of a headless compressive screw for distal interphalangeal joint arthrodesis in digits: clinical outcome and review of complications","volume":"31","author":"Brutus","year":"2006","journal-title":"J Hand Surg Am"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib12","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.jhsa.2007.09.004","article-title":"Alternative to the distal interphalangeal joint arthrodesis: lateral approach and plate fixation","volume":"33","author":"Mantovani","year":"2008","journal-title":"J Hand Surg Am"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib13","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1007\/s11552-014-9679-x","article-title":"Dimensional analysis of the distal phalanx with consideration of distal interphalangeal joint arthrodesis using a headless compression screw","volume":"10","author":"Darowish","year":"2015","journal-title":"Hand (N Y)"},{"issue":"2","key":"10.1055\/s-0043-1769091_bib14","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.jhsg.2020.12.004","article-title":"Motion and strength analysis of 2-tine staple and K-wire fixation in scapholunate ligament stabilization in a cadaver model","volume":"3","author":"Hess","year":"2021","journal-title":"J Hand Surg Glob Online"},{"issue":"2","key":"10.1055\/s-0043-1769091_bib15","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1053\/j.oto.2007.01.008","article-title":"Arthrodesis of the distal interphalangeal joint using a headless screw","volume":"17","author":"Rehak","year":"2007","journal-title":"Oper Tech Orthop"},{"key":"10.1055\/s-0043-1769091_bib16","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1007\/s00238-019-01607-w","article-title":"Distal interphalangeal joint arthrodesis using the ADS memory staple \u2013 the London experience","volume":"43","author":"Mohan","year":"2020","journal-title":"Eur J Plast Surg"},{"issue":"4","key":"10.1055\/s-0043-1769091_bib17","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1016\/j.main.2013.03.006","article-title":"Surgical treatment of degenerative osteoarthritis of the fingers","volume":"32","author":"Rongi\u00e8res","year":"2013","journal-title":"Chir Main"},{"key":"10.1055\/s-0043-1769091_bib18","article-title":"Trapeziometacarpal arthrodesis","volume":"40S","author":"Amadei","year":"2021","journal-title":"Hand Surg Rehabil"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib19","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s40634-016-0055-3","article-title":"Biomechanical evaluation of shape-memory alloy staples for internal fixation-an in vitro study","volume":"3","author":"Hoon","year":"2016","journal-title":"J Exp Orthop"},{"issue":"3","key":"10.1055\/s-0043-1769091_bib20","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1177\/1938640015620655","article-title":"The impact of nitinol staples on the compressive forces, contact area, and mechanical properties in comparison to a claw plate and crossed screws for the first tarsometatarsal arthrodesis","volume":"9","author":"Aiyer","year":"2016","journal-title":"Foot Ankle Spec"},{"issue":"4","key":"10.1055\/s-0043-1769091_bib21","first-page":"92","article-title":"The requirements and clinical performance of implants","author":"Cranin","year":"1982","journal-title":"Biocompatibility of Materials"},{"issue":"4","key":"10.1055\/s-0043-1769091_bib22","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1097\/00005131-198701040-00009","article-title":"Efficacy of bone staples for fixation","volume":"1","author":"Bargar","year":"1987","journal-title":"J Orthop Trauma"},{"issue":"19","key":"10.1055\/s-0043-1769091_bib23","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1016\/j.jor.2020.02.003","article-title":"Stress distribution in the humerus during elevation of the arm and external abduction","volume":"19","author":"Filardi","year":"2020","journal-title":"J Orthop"},{"issue":"18","key":"10.1055\/s-0043-1769091_bib24","first-page":"132","article-title":"Stress shielding analysis on easy step staple prosthesis for calcaneus fractures","volume":"18","author":"Filardi","year":"2019","journal-title":"J Orthop"},{"issue":"18","key":"10.1055\/s-0043-1769091_bib25","first-page":"63","article-title":"Stress shielding FE analysis on the temporomandibular joint","volume":"18","author":"Filardi","year":"2019","journal-title":"J Orthop"},{"issue":"3","key":"10.1055\/s-0043-1769091_bib26","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1016\/j.jor.2018.08.002","article-title":"Flatfoot and normal foot a comparative analysis of the stress shielding","volume":"15","author":"Filardi","year":"2018","journal-title":"J Orthop"},{"issue":"17","key":"10.1055\/s-0043-1769091_bib27","first-page":"44","article-title":"Tibio talar contact stress: an experimental and numerical study","volume":"17","author":"Filardi","year":"2019","journal-title":"J Orthop"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib28","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.jor.2018.01.011","article-title":"Healing of femoral fractures by the meaning of an innovative intramedullary nail","volume":"15","author":"Filardi","year":"2018","journal-title":"J Orthop"},{"issue":"15","key":"10.1055\/s-0043-1769091_bib29","doi-asserted-by":"crossref","first-page":"5365","DOI":"10.3390\/ma15155365","article-title":"Influence of structural porosity and martensite evolution on mechanical characteristics of nitinol via in-silico finite element approach","volume":"15","author":"Chekotu","year":"2022","journal-title":"Materials (Basel)"},{"key":"10.1055\/s-0043-1769091_bib30","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jmbbm.2015.06.010","article-title":"Fatigue of nitinol: the state-of-the-art and ongoing challenges","volume":"50","author":"Mahtabi","year":"2015","journal-title":"J Mech Behav Biomed Mater"},{"issue":"6","key":"10.1055\/s-0043-1769091_bib31","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1007\/s40830-020-00294-y","article-title":"Pseudoelastic NiTiNOL in orthopaedic applications history of NiTiNOL for medical applications","author":"Safranski","year":"2020","journal-title":"Shape Mem. Superelasticity"},{"issue":"6","key":"10.1055\/s-0043-1769091_bib32","doi-asserted-by":"crossref","DOI":"10.1016\/j.jhsa.2018.08.017","article-title":"Biomechanical properties of nitinol staples: effects of troughing, effective leg length, and 2-staple constructs","volume":"44","author":"McKnight","year":"2019","journal-title":"J Hand Surg Am"},{"issue":"2","key":"10.1055\/s-0043-1769091_bib33","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1177\/1553350619889274","article-title":"Literature review on the incidence of primary stapler malfunction","volume":"27","author":"Makanyengo","year":"2020","journal-title":"Surg Innov"},{"issue":"1","key":"10.1055\/s-0043-1769091_bib34","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.mporth.2018.11.012","article-title":"Management of osteoarthritis of the wrist and hand","volume":"33","author":"Islam","year":"2019","journal-title":"Orthop Trauma"},{"issue":"2","key":"10.1055\/s-0043-1769091_bib35","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jor.2013.05.001","article-title":"Long-term follow-up of trapeziectomy with abductor pollicis longus tendon interposition arthroplasty for osteoarthritis of the thumb carpometacarpal joint","volume":"10","author":"Avisar","year":"2013","journal-title":"J Orthop"},{"issue":"7","key":"10.1055\/s-0043-1769091_bib36","first-page":"305","article-title":"Surgical stapling device\u2013tissue interactions: what surgeons need to know to improve patient outcomes","author":"Chekan","year":"2014","journal-title":"J. MD"},{"key":"10.1055\/s-0043-1769091_bib37","series-title":"Principles of Orthopedic Practice for Primary Care Providers","article-title":"Hand and wrist osteoarthritis","author":"Ting","year":"2018"},{"issue":"47, Suppl 2","key":"10.1055\/s-0043-1769091_bib38","article-title":"Failure of fracture fixation in osteoporotic bone","volume":"47","author":"von R\u00fcden","year":"2016","journal-title":"Injury"},{"issue":"10","key":"10.1055\/s-0043-1769091_bib39","doi-asserted-by":"crossref","first-page":"2820","DOI":"10.1016\/j.injury.2021.08.006","article-title":"Assessing the biomechanical properties of nitinol staples in normal, osteopenic and osteoporotic bone models: a finite element analysis","volume":"52","author":"Curenton","year":"2021","journal-title":"Injury"},{"key":"10.1055\/s-0043-1769091_bib40","doi-asserted-by":"crossref","first-page":"730","DOI":"10.1016\/j.msec.2019.04.070","article-title":"Characterization of mechanical and microstructural properties of constrained groove pressed nitinol shape memory alloy for biomedical applications","volume":"102","author":"Bhardwaj","year":"2019","journal-title":"Mater Sci Eng C"}],"container-title":["Journal of Hand and Microsurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0974322724000401?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0974322724000401?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1769091.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,14]],"date-time":"2024-05-14T22:43:39Z","timestamp":1715726619000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0974322724000401"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":40,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["S0974322724000401"],"URL":"https:\/\/doi.org\/10.1055\/s-0043-1769091","relation":{},"ISSN":["0974-3227"],"issn-type":[{"value":"0974-3227","type":"print"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative Finite Element (FE) Analysis of the Mechanical Behavior in an Innovative Nitinol Staple for Arthrodesis in Distal Interphalangeal Joint","name":"articletitle","label":"Article Title"},{"value":"Journal of Hand and Microsurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1055\/s-0043-1769091","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Society for Indian Hand Surgery and Micro Surgeons. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"100040"}}