{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T15:54:07Z","timestamp":1746114847289,"version":"3.37.3"},"reference-count":21,"publisher":"Georg Thieme Verlag KG","issue":"02","license":[{"start":{"date-parts":[[2024,1,24]],"date-time":"2024-01-24T00:00:00Z","timestamp":1706054400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int Arch Otorhinolaryngol"],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Introduction\u2003Cochlear implant (CI) activation usually takes place at \u223c 30 days postoperative (PO). In our service, CI surgery is performed with local anesthesia and sedation, so activation is possible with the patient's cooperation, immediately after the CI surgery, still in the operating room (OR).<\/jats:p><jats:p>\n          Objective\u2003The objective of the present study was to provide the patient with hearing experience with the CI and to assess auditory perception immediately after surgery while still in the OR, as well as to compare impedance telemetry (IT), neural response telemetry (NRT), and comfort (C) level at two moments: in the OR and at the definitive activation, \u223c 30 days PO.<\/jats:p><jats:p>\n          Methods\u2003Nine adult patients (12 ears) with acquired (postlingual) deafness were included. Auditory perception was evaluated through the Ling Six Sound Check, musical instruments, and clapping, presented in two different programming maps, elaborated using t-NRT, and comparing IT, NRT, and C level between the two moments.<\/jats:p><jats:p>\n          Results\u2003We observed that while still in the OR, the patient can already present auditory detection and recognition responses. The values of IT, NRT threshold (t-NRT), and C on both dates differed, with statistical significance.<\/jats:p><jats:p>\n          Conclusion\u2003We concluded that it is possible to provide the patient with an auditory experience with the CI immediately after surgery, and that the auditory experience and the values of electrode IT, NRT, and C vary significantly between the two moments.<\/jats:p>","DOI":"10.1055\/s-0043-1776722","type":"journal-article","created":{"date-parts":[[2024,1,25]],"date-time":"2024-01-25T00:17:10Z","timestamp":1706141830000},"page":"e219-e225","source":"Crossref","is-referenced-by-count":1,"title":["Cochlear Implant Activation in the Immediate Postoperative Period in the Operating Room"],"prefix":"10.1055","volume":"28","author":[{"given":"Gislaine Richter Minhoto","family":"Wiemes","sequence":"additional","affiliation":[{"name":"Department of Speach Therapy, Hospital Paranaense de Otorrinolaringologia, Curitiba, PR, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nicole Richter Minhoto","family":"Wiemes","sequence":"additional","affiliation":[{"name":"Department of Speach Therapy, Hospital Paranaense de Otorrinolaringologia, Curitiba, PR, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7186-4613","authenticated-orcid":false,"given":"Bettina","family":"Carvalho","sequence":"additional","affiliation":[{"name":"Department of ENT, Universidade Federal do Paran\u00e1, Curitiba, PR, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7722-6409","authenticated-orcid":false,"given":"Rogerio","family":"Hamerschmidt","sequence":"additional","affiliation":[{"name":"Department of ENT, Universidade Federal do Paran\u00e1, Curitiba, PR, Brazil"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,1,24]]},"reference":[{"issue":"01","key":"ref1","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1590\/S0034-72992004000100019","article-title":"Neural response telemetry on the nucleus 24 multichannel cochlear implant system: literature review","volume":"70","author":"D V Ferrari","year":"2004","journal-title":"Rev Bras Otorrinolaringol"},{"issue":"01","key":"ref2","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/MAO.0b013e318278c1b2","article-title":"Cochlear implant surgery with local anesthesia and sedation: comparison with general anesthesia","volume":"34","author":"R Hamerschmidt","year":"2013","journal-title":"Otol Neurotol"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/j.joto.2014.11.002","article-title":"Clinical application of electrically evoked compound action potentials","volume":"9","author":"F Ji","year":"2014","journal-title":"J Otol"},{"issue":"03","key":"ref4","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1097\/AUD.0b013e3181c9fd86","article-title":"Neural response telemetry reconsidered: I. The relevance of ECAP threshold profiles and scaled profiles to cochlear implant fitting","volume":"31","author":"A Botros","year":"2010","journal-title":"Ear Hear"},{"issue":"03","key":"ref5","first-page":"272","article-title":"An\u00e1lise ac\u00fastica dos instrumentos sonoros musicais usados para avalia\u00e7\u00e3o audiol\u00f3gica infantil","volume":"1","author":"M F Souza","year":"2018","journal-title":"Rev Inic Cient Ext"},{"volume-title":"Foundations of spoken language for the hearing-impaired child","year":"1989","author":"D Ling","key":"ref6"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"94","DOI":"10.4067\/S0718-48162013000100016","article-title":"M\u00e9todos unisensoriales para la rehabilitaci\u00f3n de la persona con implante coclear y m\u00e9todos musicoterap\u00e9uticos como nueva herramienta de intervenci\u00f3n","volume":"73","author":"Y Quique","year":"2013","journal-title":"Rev Otorrinolaringol Cir Cabeza Cuello"},{"volume-title":"Habilidades auditivas e de linguagem de crian\u00e7as usu\u00e1rios de implante coclear an\u00e1lise dos marcadores cl\u00ednicos de desenvolvimento. [Thesis]","year":"2015","author":"M PS Comerlatto","key":"ref9"},{"issue":"01","key":"ref10","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/00003446-199902000-00005","article-title":"Summary of results using the nucleus CI24M implant to record the electrically evoked compound action potential","volume":"20","author":"P J Abbas","year":"1999","journal-title":"Ear Hear"},{"issue":"05","key":"ref11","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1590\/S0034-72992005000500018","article-title":"Telemetria de resposta neural intraoperat\u00f3ria em usu\u00e1rios de implante coclear","volume":"71","author":"M C Guedes","year":"2005","journal-title":"Rev Bras Otorrinolaringol"},{"issue":"01","key":"ref12","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/MAO.0b013e31818f57ab","article-title":"Spread of excitation measurements for the detection of electrode array foldovers: a prospective study comparing 3-dimensional rotational x-ray and intraoperative spread of excitation measurements","volume":"30","author":"W Grolman","year":"2009","journal-title":"Otol Neurotol"},{"issue":"11","key":"ref13","doi-asserted-by":"crossref","first-page":"1755","DOI":"10.1097\/00005537-199911000-00006","article-title":"Neural response telemetry with the nucleus CI24M cochlear implant","volume":"109","author":"J K Shallop","year":"1999","journal-title":"Laryngoscope"},{"key":"ref14","first-page":"201","volume-title":"Speech-processor fitting for cochlear implants","author":"S Roberts","year":"1991"},{"key":"ref15","first-page":"185","volume-title":"Device programming","author":"W Shapiro","year":"2000"},{"issue":"05","key":"ref16","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1080\/14992020400050034","article-title":"Longitudinal behaviour of neural response telemetry (NRT) data and clinical implications","volume":"43","author":"W K Lai","year":"2004","journal-title":"Int J Audiol"},{"issue":"01","key":"ref17","first-page":"68","article-title":"The importance of electrically evoked stapedial reflex in cochlear implant","volume":"80","author":"K C Andrade","year":"2014","journal-title":"Rev Bras Otorrinolaringol (Engl Ed)"},{"issue":"06","key":"ref18","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1097\/00003446-200412000-00002","article-title":"Electrically evoked compound action potential amplitude growth functions and HiResolution programming levels in pediatric CII implant subjects","volume":"25","author":"M D Eisen","year":"2004","journal-title":"Ear Hear"},{"issue":"07","key":"ref19","doi-asserted-by":"crossref","first-page":"732","DOI":"10.1080\/00016480510026890","article-title":"Comparisons between neural response imaging thresholds, electrically evoked auditory reflex thresholds and most comfortable loudness levels in CII bionic ear users with HiResolution sound processing strategies","volume":"125","author":"D M Han","year":"2005","journal-title":"Acta Otolaryngol"},{"issue":"01","key":"ref20","doi-asserted-by":"crossref","first-page":"16","DOI":"10.3766\/jaaa.21.1.3","article-title":"Comparison of electrically evoked compound action potential thresholds and loudness estimates for the stimuli used to program the Advanced Bionics cochlear implant","volume":"21","author":"E K Jeon","year":"2010","journal-title":"J Am Acad Audiol"},{"issue":"03","key":"ref21","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1007\/s12070-013-0679-x","article-title":"Electrophysiological Correlates of Behavioral Comfort Levels in Cochlear Implantees: A Prospective Study","volume":"67","author":"S Raghunandhan","year":"2015","journal-title":"Indian J Otolaryngol Head Neck Surg"},{"issue":"01","key":"ref22","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/AUD.0b013e3181906c0f","article-title":"Relation of electrically evoked compound action potential thresholds to behavioral T- and C-levels in children with cochlear implants","volume":"30","author":"B A Holstad","year":"2009","journal-title":"Ear Hear"}],"container-title":["International Archives of Otorhinolaryngology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0043-1776722.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,5]],"date-time":"2024-11-05T14:56:17Z","timestamp":1730818577000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0043-1776722"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,24]]},"references-count":21,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2024,4,11]]},"published-print":{"date-parts":[[2024,4]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0043-1776722","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["1809-9777","1809-4864"],"issn-type":[{"type":"print","value":"1809-9777"},{"type":"electronic","value":"1809-4864"}],"subject":[],"published":{"date-parts":[[2024,1,24]]}}}