{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,20]],"date-time":"2026-09-20T12:32:48Z","timestamp":1789907568444,"version":"4.0.1"},"reference-count":25,"publisher":"Georg Thieme Verlag KG","issue":"02","funder":[{"name":"KOOR (University Hospitals Leuven","award":["nr S59540"],"award-info":[{"award-number":["nr S59540"]}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Wrist Surg"],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n          Purpose\u2003A technique to measure scapholunate distance based on four-dimensional computed tomography (4D CT)-acquired images is presented.<\/jats:p><jats:p>\n          Materials and Methods\u2003Intra-observer variability was evaluated through a repeated-measures study. A 4D CT of seven patients suspected of scapholunate lesion was performed. Anatomical landmarks were identified on a three-dimensional reconstructed model of the wrist. All 4D CT datasets were evaluated thrice by two observers. Standard deviation of the differences between two measurements, interclass correlation coefficient (ICC), standard error of measurement (SEM), and minimal detectable change (MDC) were calculated.<\/jats:p><jats:p>\n          Results\u2003Intra-observer variability for the expert observer (ICC\u2009&gt;\u20090.95) was lower than that of the novice observer (ICC\u2009&gt;\u20090.77) and interobserver variability was low (ICC\u2009&gt;\u20090.85). For the expert observer, measurement error (SEM\u2009&lt;\u20090.13\u2009mm and MDC\u2009&lt;\u20090.36\u2009mm) was smaller than that of the novice observer (SEM\u2009&lt;\u20090.45\u2009mm and MDC\u2009&lt;\u20091.24\u2009mm). Both SEM and MDC values were low, compared to the scan resolution and the absolute value of intervals.<\/jats:p><jats:p>\n          Conclusion\u2003The proposed assessment results in a reproducible and reliable measurement of scapholunate distance.<\/jats:p>","DOI":"10.1055\/s-0044-1786161","type":"journal-article","created":{"date-parts":[[2024,4,16]],"date-time":"2024-04-16T23:25:12Z","timestamp":1713309912000},"page":"177-183","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of Reliability of Dynamic Scapholunate Distance Measured on 4D CT-Acquired Images"],"prefix":"10.1055","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5045-9325","authenticated-orcid":false,"given":"Sofie","family":"Goeminne","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"},{"name":"Department of Orthopaedic Surgery, AZ Herentals, Herentals, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emiel","family":"Salaets","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Walter","family":"Coudyzer","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darshan","family":"Shah","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"},{"name":"Department of Mechanical Engineering, BiOME Lab, Indian Institute of Technology, Bombay, Mumbai, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ilse","family":"Degreef","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lennart","family":"Scheys","sequence":"additional","affiliation":[{"name":"Department of Development and Regeneration, Institute for Orthopedic Research and Training, KU Leuven, Leuven, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2024,4,16]]},"reference":[{"issue":"06","key":"ref1","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/j.jhsa.2008.04.027","article-title":"Scapholunate instability: current concepts in diagnosis and management","volume":"33","author":"C E Kuo","year":"2008","journal-title":"J Hand Surg Am"},{"issue":"10","key":"ref2","doi-asserted-by":"crossref","first-page":"2175","DOI":"10.1016\/j.jhsa.2012.07.035","article-title":"Scapholunate instability: current concepts in diagnosis and management","volume":"37","author":"A Kitay","year":"2012","journal-title":"J Hand Surg Am"},{"issue":"02","key":"ref3","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1055\/s-0033-1345265","article-title":"The EWAS classification of scapholunate tears: an anatomical arthroscopic study","volume":"2","author":"J C Messina","year":"2013","journal-title":"J Wrist Surg"},{"issue":"01","key":"ref4","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/j.jhsa.2005.10.011","article-title":"Three-ligament tenodesis for the treatment of scapholunate dissociation: indications and surgical technique","volume":"31","author":"M Garcia-Elias","year":"2006","journal-title":"J Hand Surg Am"},{"issue":"02","key":"ref5","doi-asserted-by":"crossref","first-page":"233","DOI":"10.1007\/s11552-014-9695-x","article-title":"Comparisons of three radiographic views in assessing for scapholunate instability","volume":"10","author":"R M Patel","year":"2015","journal-title":"Hand (N Y)"},{"issue":"07","key":"ref6","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.1016\/j.jhsa.2011.05.009","article-title":"Comparison of radiographic stress views for scapholunate dynamic instability in a cadaver model","volume":"36","author":"S K Lee","year":"2011","journal-title":"J Hand Surg Am"},{"issue":"09","key":"ref7","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1016\/j.acra.2016.04.006","article-title":"Scapholunate interosseous ligament tears: diagnostic performance of 1.5T, 3T MRI and MR arthrography \u2013 a systematic review and meta-analysis","volume":"23","author":"N Hafezi-Nejad","year":"2016","journal-title":"Acad Radiol"},{"issue":"03","key":"ref8","doi-asserted-by":"crossref","first-page":"1008","DOI":"10.1148\/radiol.2373041450","article-title":"Interosseous ligament tears of the wrist: comparison of multi-detector row CT arthrography and MR imaging","volume":"237","author":"M R Schmid","year":"2005","journal-title":"Radiology"},{"issue":"02","key":"ref9","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s11552-013-9499-4","article-title":"Scapholunate ligament injuries: a review of current concepts","volume":"8","author":"I P Pappou","year":"2013","journal-title":"Hand (N Y)"},{"issue":"05","key":"ref10","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1111\/1754-9485.12326","article-title":"Four-dimensional computed tomography (4DCT): a review of the current status and applications","volume":"59","author":"Y Kwong","year":"2015","journal-title":"J Med Imaging Radiat Oncol"},{"issue":"04","key":"ref11","doi-asserted-by":"crossref","first-page":"1048","DOI":"10.1109\/TMI.2018.2877503","article-title":"Evaluation of a quantitative method for carpal motion analysis using clinical 3-D and 4-D protocols","volume":"38","author":"J GG Dobbe","year":"2019","journal-title":"IEEE Trans Med Imaging"},{"issue":"11","key":"ref12","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1302\/0301-620X.101B11.BJJ-2019-0361.R1","article-title":"The use of 4D-CT in assessing wrist kinematics and pathology: a narrative view","volume":"101-B","author":"J White","year":"2019","journal-title":"Bone Joint J"},{"issue":"02","key":"ref13","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1007\/s00256-020-03543-4","article-title":"Quantifying in vivo scaphoid, lunate, and capitate kinematics using four-dimensional computed tomography","volume":"50","author":"M Brinkhorst","year":"2021","journal-title":"Skeletal Radiol"},{"issue":"07","key":"ref14","doi-asserted-by":"crossref","first-page":"0745011","DOI":"10.1115\/1.4030405","article-title":"A technique for quantifying wrist motion using four-dimensional computed tomography: approach and validation","volume":"137","author":"K Zhao","year":"2015","journal-title":"J Biomech Eng"},{"issue":"12","key":"ref15","doi-asserted-by":"crossref","first-page":"1699","DOI":"10.1016\/j.medengphy.2014.08.011","article-title":"A method for carpal motion hysteresis quantification in 4-dimensional imaging of the wrist","volume":"36","author":"I S Mat Jais","year":"2014","journal-title":"Med Eng Phys"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1002\/uog.5256","article-title":"Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables","volume":"31","author":"J W Bartlett","year":"2008","journal-title":"Ultrasound Obstet Gynecol"},{"issue":"04","key":"ref17","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1177\/1753193416641590","article-title":"Why and how to report surgeons' levels of expertise","volume":"41","author":"J B Tang","year":"2016","journal-title":"J Hand Surg Eur Vol"},{"issue":"08","key":"ref18","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.jhsa.2006.06.005","article-title":"In vivo elongation of the palmar and dorsal scapholunate interosseous ligament","volume":"31","author":"M A Upal","year":"2006","journal-title":"J Hand Surg Am"},{"issue":"01","key":"ref19","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jbiomech.2005.11.015","article-title":"Coordinate systems for the carpal bones of the wrist","volume":"40","author":"J C Coburn","year":"2007","journal-title":"J Biomech"},{"issue":"8476","key":"ref20","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"J M Bland","year":"1986","journal-title":"Lancet"},{"issue":"11","key":"ref21","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1016\/j.diii.2020.09.008","article-title":"3D reconstructions, 4D imaging and postprocessing with CT in musculoskeletal disorders: past, present and future","volume":"101","author":"A Blum","year":"2020","journal-title":"Diagn Interv Imaging"},{"issue":"03","key":"ref22","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1007\/s00776-014-0533-3","article-title":"Comparison of scapholunate distance measurements on plain radiography and computed tomography for the diagnosis of scapholunate instability associated with distal radius fracture","volume":"19","author":"D Suzuki","year":"2014","journal-title":"J Orthop Sci"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"3159","DOI":"10.1038\/s41598-023-29726-2","article-title":"Quantification of the methodological error in kinematic evaluation of the DRUJ using dynamic CT","volume":"13","author":"J GM Oonk","year":"2023","journal-title":"Sci Rep"},{"issue":"06","key":"ref24","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1177\/1558944717726372","article-title":"Dynamic CT scan of the normal scapholunate joint in a clenced fist and radial and ulnar deviation","volume":"13","author":"P M Kelly","year":"2018","journal-title":"Hand (N Y)"},{"issue":"02","key":"ref25","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","article-title":"A guideline of selecting and reporting intraclass correlation coefficients for reliability research","volume":"15","author":"T K Koo","year":"2016","journal-title":"J Chiropr Med"}],"container-title":["Journal of Wrist Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0044-1786161.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T02:28:14Z","timestamp":1742956094000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0044-1786161"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,16]]},"references-count":25,"journal-issue":{"issue":"02","published-online":{"date-parts":[[2025,3,25]]},"published-print":{"date-parts":[[2025,4]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0044-1786161","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["2163-3916","2163-3924"],"issn-type":[{"value":"2163-3916","type":"print"},{"value":"2163-3924","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,16]]}}}