{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,7]],"date-time":"2026-03-07T18:40:57Z","timestamp":1772908857851,"version":"3.50.1"},"reference-count":7,"publisher":"Georg Thieme Verlag KG","issue":"03","license":[{"start":{"date-parts":[[2024,12,17]],"date-time":"2024-12-17T00:00:00Z","timestamp":1734393600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Radiol Imaging"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>\n               Objectives\u2003The aim of the study was to evaluate role of shear wave elastography (SWE) using a novel methodology for differentiation of benign and malignant cervical lymph nodes.<\/jats:p><jats:p>\n               Materials and Methods\u2003SWE was performed on 38 patients who presented with cervical lymph adenopathy. Color-coded elasticity maps were obtained, from which the stiffest region of interest (ROI) with a diameter of 2\u2009mm was chosen. Maximum and mean Young's modulus values (Kpa) were calculated in selected 2-mm ROI. Finally, the results were correlated with the fine needle aspiration cytology findings in all patients to assess the diagnostic accuracy, sensitivity, and specificity at a defined cutoff value for distinguishing between benign and malignant lymphadenopathies.<\/jats:p><jats:p>\n               Results\u2003There were 20 malignant cervical lymph nodes and 18 benign cervical lymph nodes. Malignant nodes showed significantly higher mean Young's modulus value (154.2\u2009\u00b1\u200946.19 kPa) compared with benign nodes (70.39\u2009\u00b1\u200930.76 kPa), with a p-value of less than 0.0001. Our findings indicate that the mean Young modulus value within a standardized 2-mm ROI outperformed grayscale ultrasound in terms of diagnostic accuracy (92.1 vs. 78.9%), sensitivity (100 vs. 80%), and specificity (83.3 vs. 77.7%), with the established cutoff values for high diagnostic accuracy indicating malignancy as greater than 92 for mean Young's modulus with an area under the curve of 0.964.<\/jats:p><jats:p>\n               Conclusion\u2003SWE using a standardized 2-mm ROI provides improved sensitivity and diagnostic accuracy for differentiation of benign and malignant lymph node lesions.<\/jats:p>","DOI":"10.1055\/s-0044-1800881","type":"journal-article","created":{"date-parts":[[2024,12,18]],"date-time":"2024-12-18T00:22:16Z","timestamp":1734481336000},"page":"418-423","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of Benign and Malignant Cervical Lymphadenopathy: A Comparative Study of Shear Wave Elastography and Grayscale Ultrasound"],"prefix":"10.1055","volume":"35","author":[{"given":"Gaurav","family":"Gaurav","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shahina","family":"Bano","sequence":"additional","affiliation":[{"name":"Department of Radiodiagnosis, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prajwala","family":"Gupta","sequence":"additional","affiliation":[{"name":"Department of Pathology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr. Ram Manohar Lohia Hospital, New Delhi, India"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2024,12,17]]},"reference":[{"issue":"04","key":"ref1","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1102\/1470-7330.2013.0056","article-title":"Review of ultrasonography of malignant neck nodes: greyscale, Doppler, contrast enhancement and elastography","volume":"13","author":"M Ying","year":"2014","journal-title":"Cancer Imaging"},{"issue":"01","key":"ref2","doi-asserted-by":"crossref","first-page":"37","DOI":"10.7863\/ultra.34.1.37","article-title":"Differentiation of metastatic cervical lymph nodes with ultrasound elastography by virtual touch tissue imaging: preliminary study","volume":"34","author":"D Che","year":"2015","journal-title":"J Ultrasound Med"},{"issue":"02","key":"ref3","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/j.ultrasmedbio.2011.10.024","article-title":"Shear wave elasticity imaging of cervical lymph nodes","volume":"38","author":"K SS Bhatia","year":"2012","journal-title":"Ultrasound Med Biol"},{"issue":"05","key":"ref4","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1055\/s-0032-1325330","article-title":"Reliability of shear wave ultrasound elastography for neck lesions identified in routine clinical practice","volume":"33","author":"K Bhatia","year":"2012","journal-title":"Ultraschall Med"},{"issue":"08","key":"ref5","doi-asserted-by":"crossref","first-page":"e0221062","DOI":"10.1371\/journal.pone.0221062","article-title":"Incorporation of shear wave elastography into a prediction model in the assessment of cervical lymph nodes","volume":"14","author":"W C Lo","year":"2019","journal-title":"PLoS One"},{"issue":"02","key":"ref6","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.ultrasmedbio.2015.10.019","article-title":"Shear wave elastography in head and neck lymph node assessment: image quality and diagnostic impact compared with B-mode and Doppler ultrasonography","volume":"42","author":"F Desmots","year":"2016","journal-title":"Ultrasound Med Biol"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"157","DOI":"10.14366\/usg.15007","article-title":"Ultrasound elastography for evaluation of cervical lymph nodes","volume":"34","author":"Y J Choi","year":"2015","journal-title":"Ultrasonography"}],"container-title":["Indian Journal of Radiology and Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0044-1800881.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,16]],"date-time":"2025-06-16T22:38:44Z","timestamp":1750113524000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0044-1800881"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,12,17]]},"references-count":7,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2025,6,16]]},"published-print":{"date-parts":[[2025,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0044-1800881","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0971-3026","1998-3808"],"issn-type":[{"value":"0971-3026","type":"print"},{"value":"1998-3808","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,12,17]]}}}