{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T07:16:44Z","timestamp":1764314204444,"version":"3.46.0"},"reference-count":33,"publisher":"Georg Thieme Verlag KG","issue":"04","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Vet Comp Orthop Traumatol"],"published-print":{"date-parts":[[2025,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Objective\u2003To determine the effect of locking head inserts (LHI) on plate strain, stiffness, and deformation when applied to a 3.5-mm broad locking compression plate (LCP) in an open fracture-gap model.<\/jats:p>\n                  <jats:p>Study Design\u2003Six, 13-hole, 3.5-mm broad LCP were secured to epoxy bone models with a 10\u2009mm central defect and 1\u2009mm plate offset. Two peripheral locking screws were placed in each segment, with the remaining screw holes left unfilled. Three strain gauges were glued to each LCP at anticipated regions of maximum strain. Constructs underwent cyclic uniaxial loading at a rate of 20\u2009mm\/min to 400\u2009N in three different configurations (Configuration 1: no LHI, Configuration 2: 3 LHI, Configuration 3: 9 LHI). LHI were tightened to 4 Nm of torque. A data acquisition system was used to collect implant strain during testing. Construct stiffness and deformation were recorded by the biomechanical testing machine.<\/jats:p>\n                  <jats:p>Results\u2003Maximum implant strain was recorded at the central screw hole directly over the simulated fracture gap in all configurations (Mdn 1,837.3 \u00b5\u03b5 [interquartile range: 1,805.1\u20131,862.0]). There was no difference in implant peak-to-peak strain with addition of LHI at all three gauges (Gauge 1 [p\u2009=\u20090.847], Gauge 2 [p\u2009=\u20090.847], Gauge 3 [p\u2009=\u20090.311]). Similarly, peak-to-peak displacement (p\u2009=\u20090.069) and axial construct stiffness (p\u2009=\u20090.311) did not change with the addition of LHI.<\/jats:p>\n                  <jats:p>Conclusion\u2003The addition of LHI to a 3.5-mm broad LCP construct was not shown to have an effect on plate strain, stiffness, or deformation.<\/jats:p>","DOI":"10.1055\/s-0044-1800973","type":"journal-article","created":{"date-parts":[[2025,1,21]],"date-time":"2025-01-21T19:24:52Z","timestamp":1737487492000},"page":"178-185","source":"Crossref","is-referenced-by-count":0,"title":["The Effect of Locking Head Inserts on the Biomechanical Properties of a 3.5-mm Broad Locking Compression Plate When Used in an Open Fracture-Gap Model"],"prefix":"10.1055","volume":"38","author":[{"given":"William T. G.","family":"Hawker","sequence":"additional","affiliation":[{"name":"Department of Clinical Studies, The Ontario Veterinary College, Guelph, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Noel","family":"Moens","sequence":"additional","affiliation":[{"name":"Department of Clinical Studies, The Ontario Veterinary College, Guelph, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bruce","family":"Guest","sequence":"additional","affiliation":[{"name":"School of Engineering, University of Guelph, Guelph, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michelle","family":"Oblak","sequence":"additional","affiliation":[{"name":"Department of Clinical Studies, The Ontario Veterinary College, Guelph, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melissa","family":"MacIver","sequence":"additional","affiliation":[{"name":"Department of Clinical Studies, The Ontario Veterinary College, Guelph, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Runciman","sequence":"additional","affiliation":[{"name":"School of Engineering, University of Guelph, Guelph, Ontario, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2025,1,21]]},"reference":[{"issue":"08","key":"ref1","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology","volume":"84","author":"S M Perren","year":"2002","journal-title":"J Bone Joint Surg Br"},{"issue":"06","key":"ref2","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1007\/BF00636165","article-title":"Biological internal fixation of fractures","volume":"109","author":"C Gerber","year":"1990","journal-title":"Arch Orthop Trauma Surg"},{"issue":"S 01","key":"ref3","first-page":"1","article-title":"The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Scientific background, design and application","volume":"22","author":"S M Perren","year":"1991","journal-title":"Injury"},{"issue":"354","key":"ref4","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1097\/00003086-199809000-00024","article-title":"The evolution of femoral shaft plating technique","author":"S R Rozbruch","year":"1998","journal-title":"Clin Orthop Relat Res"},{"issue":"05","key":"ref5","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/BF00454343","article-title":"Severely comminuted femoral shaft fractures: treatment by bridging-plate osteosynthesis","volume":"106","author":"U Heitemeyer","year":"1987","journal-title":"Arch Orthop Trauma Surg"},{"issue":"S 01","key":"ref6","doi-asserted-by":"crossref","first-page":"A13","DOI":"10.1016\/S0020-1383(97)90111-X","article-title":"Minimally invasive plate fixation in femoral shaft fractures","volume":"28","author":"K Wenda","year":"1997","journal-title":"Injury"},{"issue":"03","key":"ref7","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jcot.2014.07.010","article-title":"Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - a prospective series of 50 patients","volume":"5","author":"S V Paluvadi","year":"2014","journal-title":"J Clin Orthop Trauma"},{"issue":"S 02","key":"ref8","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/S0020-1383(01)00127-9","article-title":"Locking compression plate (LCP). An osteosynthesis plate based on the dynamic compression plate and the point contact fixator (PC-Fix)","volume":"32","author":"R Frigg","year":"2001","journal-title":"Injury"},{"issue":"04","key":"ref9","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1055\/s-0038-1632958","article-title":"In vitro biomechanical comparison of limited contat dynamic compression plate and locking compression plate","volume":"18","author":"A Z Aguila","year":"2005","journal-title":"Vet Comp Orthop Traumatol"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1007\/s00402-002-0465-9","article-title":"Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens","volume":"123","author":"H Lill","year":"2003","journal-title":"Arch Orthop Trauma Surg"},{"issue":"06","key":"ref11","doi-asserted-by":"crossref","first-page":"430","DOI":"10.3415\/VCOT-14-01-0001","article-title":"A comparison of conventional compression plates and locking compression plates using cantilever bending in an ilial fracture model","volume":"27","author":"C W Bruce","year":"2014","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"06","key":"ref12","doi-asserted-by":"crossref","first-page":"408","DOI":"10.3415\/VCOT-11-04-0061","article-title":"Single cycle to failure in bending of three standard and five locking plates and plate constructs","volume":"24","author":"C A Blake","year":"2011","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"09","key":"ref13","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/01.bot.0000174033.30054.5f","article-title":"The mechanical behavior of locking compression plates compared with dynamic compression plates in a cadaver radius model","volume":"19","author":"M J Gardner","year":"2005","journal-title":"J Orthop Trauma"},{"issue":"06","key":"ref14","doi-asserted-by":"crossref","first-page":"418","DOI":"10.3415\/VCOT-11-04-0050","article-title":"Single cycle to failure in torsion of three standard and five locking plate constructs","volume":"24","author":"J B Cabassu","year":"2011","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"01","key":"ref15","doi-asserted-by":"crossref","first-page":"23","DOI":"10.2460\/ajvr.70.1.23","article-title":"Comparison of the mechanical behaviors of semicontoured, locking plate-rod fixation and anatomically contoured, conventional plate-rod fixation applied to experimentally induced gap fractures in canine femora","volume":"70","author":"C SS Goh","year":"2009","journal-title":"Am J Vet Res"},{"issue":"04","key":"ref16","doi-asserted-by":"crossref","first-page":"318","DOI":"10.3415\/VCOT-07-04-0034","article-title":"Mechanical testing of 3.5\u2009mm locking and non-locking bone plates","volume":"21","author":"M DeTora","year":"2008","journal-title":"Vet Comp Orthop Traumatol"},{"issue":"S 02","key":"ref17","doi-asserted-by":"crossref","first-page":"B63","DOI":"10.1016\/j.injury.2003.09.026","article-title":"Guidelines for the clinical application of the LCP","volume":"34","author":"E Gautier","year":"2003","journal-title":"Injury"},{"issue":"10","key":"ref18","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1016\/j.clinbiomech.2007.08.004","article-title":"A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing","volume":"22","author":"D L Miller","year":"2007","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"07","key":"ref19","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1111\/vsu.12368","article-title":"Mechanical evaluation of locking, nonlocking, and hybrid plating constructs using a locking compression plate in a canine synthetic bone model","volume":"44","author":"K M Rowe-Guthrie","year":"2015","journal-title":"Vet Surg"},{"issue":"09","key":"ref20","first-page":"1962","article-title":"Hybrid locked plating of osteoporotic fractures of the humerus","volume":"88","author":"M J Gardner","year":"2006","journal-title":"J Bone Joint Surg Am"},{"issue":"S 02","key":"ref21","doi-asserted-by":"crossref","first-page":"B43","DOI":"10.1016\/j.injury.2003.09.024","article-title":"First clinical results of the locking compression plate (LCP)","volume":"34","author":"C Sommer","year":"2003","journal-title":"Injury"},{"issue":"02","key":"ref22","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1302\/0301-620X.94B2.27440","article-title":"Does plugging unused combination screw holes improve the fatigue life of fixation with locking plates in comminuted supracondylar fractures of the femur?","volume":"94","author":"R Firoozabadi","year":"2012","journal-title":"J Bone Joint Surg Br"},{"issue":"01","key":"ref24","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1186\/s40634-021-00424-0","article-title":"The effects of locking inserts and overtorque on the mechanical properties of a large fragment locking compression plate","volume":"8","author":"K N Meyers","year":"2021","journal-title":"J Exp Orthop"},{"issue":"S 02","key":"ref27","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP\u2013how can stability in locked internal fixators be controlled?","volume":"34","author":"K Stoffel","year":"2003","journal-title":"Injury"},{"issue":"05","key":"ref28","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/j.engfailanal.2007.04.001","article-title":"Fatigue failure of an orthopedic implant \u2013 a locking compression plate","volume":"15","author":"C Kanchanomai","year":"2008","journal-title":"Eng Fail Anal"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"e122","DOI":"10.1055\/s-0043-1774371","article-title":"The effect of working length, fracture, and screw configuration on plate strain in a 3.5-mm LCP bone model of comminuted fractures","volume":"06","author":"S H Wainberg","year":"2023","journal-title":"VCOT Open"},{"issue":"05","key":"ref30","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/00005131-200106000-00005","article-title":"Screw position affects dynamic compression plate strain in an in vitro fracture model","volume":"15","author":"T Ellis","year":"2001","journal-title":"J Orthop Trauma"},{"issue":"02","key":"ref31","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1097\/BOT.0b013e3181dc56b1","article-title":"Threaded screw head inserts improve locking plate biomechanical properties","volume":"25","author":"J Bellapianta","year":"2011","journal-title":"J Orthop Trauma"},{"issue":"03","key":"ref32","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1097\/BOT.0000000000001387","article-title":"Locking hole inserts: effect of insertion torque on fatigue performance and insert loosening in locking plates","volume":"33","author":"J Y Zhang","year":"2019","journal-title":"J Orthop Trauma"},{"issue":"01","key":"ref33","doi-asserted-by":"crossref","first-page":"19","DOI":"10.3928\/01477447-20101123-13","article-title":"Analysis of the mechanical properties of locking plates with and without screw hole inserts","volume":"34","author":"J K Eichinger","year":"2011","journal-title":"Orthopedics"},{"issue":"S 02","key":"ref34","doi-asserted-by":"crossref","first-page":"B6","DOI":"10.1016\/j.injury.2003.09.020","article-title":"Development of the locking compression plate","volume":"34","author":"R Frigg","year":"2003","journal-title":"Injury"},{"issue":"01","key":"ref35","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1123\/jab.26.1.10","article-title":"Stiffness and endurance of a locking compression plate fixed on fractured femur","volume":"26","author":"C Kanchanomai","year":"2010","journal-title":"J Appl Biomech"},{"issue":"12","key":"ref37","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1302\/2046-3758.712.BJR-2018-0083.R1","article-title":"Screw head plugs increase the fatigue strength of stainless steel, but not of titanium, locking plates","volume":"7","author":"L-W Hung","year":"2019","journal-title":"Bone Joint Res"}],"container-title":["Veterinary and Comparative Orthopaedics and Traumatology"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0044-1800973.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,28]],"date-time":"2025-11-28T07:12:19Z","timestamp":1764313939000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0044-1800973"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,21]]},"references-count":33,"journal-issue":{"issue":"04","published-online":{"date-parts":[[2025,7,15]]},"published-print":{"date-parts":[[2025,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0044-1800973","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0932-0814","2567-6911"],"issn-type":[{"type":"print","value":"0932-0814"},{"type":"electronic","value":"2567-6911"}],"subject":[],"published":{"date-parts":[[2025,1,21]]}}}