{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T22:48:28Z","timestamp":1782254908322,"version":"3.54.5"},"reference-count":33,"publisher":"Georg Thieme Verlag KG","issue":"03","license":[{"start":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T00:00:00Z","timestamp":1755820800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Indian J Radiol Imaging"],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This article aims to investigate the clinical usefulness of sialography with cone beam computed tomography (CBCT), also known as Sialo-CBCT, for the diagnosis of salivary gland diseases.<\/jats:p>\n                  <jats:p>Literature search was performed in PubMed and Web of Science databases with search terminologies \u201csialography, cone beam computed tomography sialography, salivary gland diseases.\u201d Thirteen articles that examined the diagnostic potential of Sialo-CBCT were included in the present review. The search complied with PRISMA criteria, and the protocol was registered in the PROSPERO [CRD42024503038].<\/jats:p>\n                  <jats:p>Out of thirteen publications included in the review, three were studies that optimized the effective dosage and image quality in Sialo-CBCT and ten remaining included imaging performed in patients with salivary gland diseases.<\/jats:p>\n                  <jats:p>The findings suggest that 3D CBCT combined with sialography has good diagnostic potential in visualizing the ductal subdivisions and anatomy of the salivary glands as well as the identification of salivary gland pathologies. Characteristic features of imaging modalities such as plain radiography, ultrasonography, CT-sialography, MR-sialography, and CBCT-sialography were outlined in the review.<\/jats:p>","DOI":"10.1055\/s-0045-1811209","type":"journal-article","created":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T22:56:02Z","timestamp":1755903362000},"page":"290-299","source":"Crossref","is-referenced-by-count":0,"title":["Diagnostic Efficacy of Cone Beam Computed Tomography Sialography (Sialo-CBCT) in Salivary Gland Pathologies: A Systematic Review"],"prefix":"10.1055","volume":"36","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-2676-5349","authenticated-orcid":false,"given":"Smrithy K.","family":"Sivadas","sequence":"additional","affiliation":[{"name":"NITTE (Deemed to be University), AB Shetty Memorial Institute of Dental Sciences (ABSMIDS), Department of Oral Medicine and Radiology, Mangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0744-5593","authenticated-orcid":false,"given":"Shruthi","family":"Hegde","sequence":"additional","affiliation":[{"name":"NITTE (Deemed to be University), AB Shetty Memorial Institute of Dental Sciences (ABSMIDS), Department of Oral Medicine and Radiology, Mangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5744-9322","authenticated-orcid":false,"given":"Vidya","family":"Ajila","sequence":"additional","affiliation":[{"name":"NITTE (Deemed to be University), AB Shetty Memorial Institute of Dental Sciences (ABSMIDS), Department of Oral Medicine and Radiology, Mangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9617-8959","authenticated-orcid":false,"family":"Tannishtha","sequence":"additional","affiliation":[{"name":"NITTE (Deemed to be University), AB Shetty Memorial Institute of Dental Sciences (ABSMIDS), Department of Oral Medicine and Radiology, Mangalore, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"194","published-online":{"date-parts":[[2025,8,22]]},"reference":[{"issue":"01","key":"ref1","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1186\/s12903-023-03159-9","article-title":"A comparative study of three-dimensional cone-beam CT sialography and MR sialography for the detection of non-tumorous salivary pathologies","volume":"23","author":"H Bertin","year":"2023","journal-title":"BMC Oral Health"},{"issue":"06","key":"ref2","doi-asserted-by":"crossref","first-page":"e452","DOI":"10.1016\/j.oooo.2014.02.023","article-title":"The feasibility of cone beam computed tomographic sialography in the diagnosis of space-occupying lesions: report of 3 cases","volume":"117","author":"S Shahidi","year":"2014","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"issue":"01","key":"ref3","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/cpf.12199","article-title":"Imaging of the major salivary glands","volume":"36","author":"P Afzelius","year":"2016","journal-title":"Clin Physiol Funct Imaging"},{"issue":"04","key":"ref4","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.bjoms.2010.03.002","article-title":"Imaging the major salivary glands","volume":"49","author":"C J Burke","year":"2011","journal-title":"Br J Oral Maxillofac Surg"},{"issue":"01","key":"ref5","doi-asserted-by":"crossref","first-page":"20110319","DOI":"10.1259\/dmfr.20110319","article-title":"A comparative study of the diagnostic capabilities of 2D plain radiograph and 3D cone beam CT sialography","volume":"42","author":"F M Jadu","year":"2013","journal-title":"Dentomaxillofac Radiol"},{"issue":"01","key":"ref6","doi-asserted-by":"crossref","first-page":"112","DOI":"10.3109\/00016489609137723","article-title":"Ultrafast computed tomography and three-dimensional image processing of CT sialography in patients with parotid masses poorly defined by magnetic resonance imaging","volume":"116","author":"D H Szolar","year":"1996","journal-title":"Acta Otolaryngol"},{"issue":"04","key":"ref7","doi-asserted-by":"crossref","first-page":"1033","DOI":"10.1148\/radiographics.21.4.g01jl271033","article-title":"Fluoroscopy: patient radiation exposure issues","volume":"21","author":"M Mahesh","year":"2001","journal-title":"Radiographics"},{"issue":"01","key":"ref8","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.tripleo.2010.03.013","article-title":"Salivary calculus diagnosis with 3-dimensional cone-beam computed tomography","volume":"110","author":"T Dreiseidler","year":"2010","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod"},{"issue":"03","key":"ref9","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1007\/BF00596550","article-title":"CT of submandibular gland sialolithiasis","volume":"38","author":"E Avrahami","year":"1996","journal-title":"Neuroradiology"},{"issue":"01","key":"ref10","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1002\/bjs.4789","article-title":"Modern management of salivary calculi","volume":"92","author":"M McGurk","year":"2005","journal-title":"Br J Surg"},{"issue":"05","key":"ref11","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1259\/dmfr\/90784441","article-title":"Cone beam computed sialography of sialoliths","volume":"38","author":"N A Drage","year":"2009","journal-title":"Dentomaxillofac Radiol"},{"issue":"973","key":"ref12","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1259\/bjr\/31419627","article-title":"Effective dose from cone beam CT examinations in dentistry","volume":"82","author":"J A Roberts","year":"2009","journal-title":"Br J Radiol"},{"issue":"71","key":"ref13","doi-asserted-by":"crossref","first-page":"n71","DOI":"10.1136\/bmj.n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"M J Page","year":"2021","journal-title":"BMJ"},{"issue":"09","key":"ref14","doi-asserted-by":"crossref","first-page":"1284","DOI":"10.1177\/1049732302238251","article-title":"Appraising the evidence: reviewing disparate data systematically","volume":"12","author":"S Hawker","year":"2002","journal-title":"Qual Health Res"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1186\/1748-5908-9-2","article-title":"A qualitative systematic review of studies using the normalization process theory to research implementation processes","volume":"9","author":"R McEvoy","year":"2014","journal-title":"Implement Sci"},{"issue":"05","key":"ref16","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1259\/dmfr\/62878962","article-title":"A comparative study of the effective radiation doses from cone beam computed tomography and plain radiography for sialography","volume":"39","author":"F Jadu","year":"2010","journal-title":"Dentomaxillofac Radiol"},{"issue":"06","key":"ref17","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1259\/dmfr\/81159071","article-title":"Optimization of exposure parameters for cone beam computed tomography sialography","volume":"40","author":"F M Jadu","year":"2011","journal-title":"Dentomaxillofac Radiol"},{"issue":"05","key":"ref18","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.oooo.2022.12.012","article-title":"Optimizing effective dose and image quality in cone beam CT sialography","volume":"135","author":"D J Douglas","year":"2023","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"425","DOI":"10.4103\/0972-1363.155635","article-title":"Resourcefulness of cone beam computed sialography in detection of multiple radiolucent sialoliths: a case report","volume":"26","author":"T J Elenjickal","year":"2014","journal-title":"J Indian Acad Oral Med Radiol"},{"issue":"02","key":"ref20","doi-asserted-by":"crossref","first-page":"209","DOI":"10.5624\/isd.20200313","article-title":"Three-dimensional cone-beam computed tomographic sialography in the diagnosis and management of primary Sj\u00f6gren syndrome: report of 3 cases","volume":"51","author":"N Thomas","year":"2021","journal-title":"Imaging Sci Dent"},{"issue":"05","key":"ref21","doi-asserted-by":"crossref","first-page":"20220371","DOI":"10.1259\/dmfr.20220371","article-title":"A comparative study of three-dimensional cone beam computed tomographic sialography and ultrasonography in the detection of non-tumoral salivary duct diseases","volume":"52","author":"V Cetinkaya","year":"2023","journal-title":"Dentomaxillofac Radiol"},{"issue":"01","key":"ref22","doi-asserted-by":"crossref","first-page":"20150431","DOI":"10.1259\/dmfr.20150431","article-title":"Three-dimensional cone-beam CT sialography in non tumour salivary pathologies: procedure and results","volume":"46","author":"H Bertin","year":"2017","journal-title":"Dentomaxillofac Radiol"},{"issue":"01","key":"ref23","doi-asserted-by":"crossref","first-page":"17","DOI":"10.5624\/isd.2013.43.1.17","article-title":"Assessment of the role of cone beam computed sialography in diagnosing salivary gland lesions","volume":"43","author":"N Abdel-Wahed","year":"2013","journal-title":"Imaging Sci Dent"},{"issue":"06","key":"ref24","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.oooo.2015.09.005","article-title":"Cone beam computed tomography (CBCT) sialography \u2013 an adjunct to salivary gland ultrasonography in the evaluation of recurrent salivary gland swelling","volume":"120","author":"T Kroll","year":"2015","journal-title":"Oral Surg Oral Med Oral Pathol Oral Radiol"},{"key":"ref25","doi-asserted-by":"crossref","first-page":"47","DOI":"10.4103\/jcis.JCIS_45_18","article-title":"Review of the major and minor salivary glands, Part 1: Anatomy, infectious, and inflammatory processes","volume":"8","author":"A T Kessler","year":"2018","journal-title":"J Clin Imaging Sci"},{"issue":"02","key":"ref26","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1002\/lary.20008","article-title":"Outcome of minimally invasive management of salivary calculi in 4,691 patients","volume":"119","author":"H Iro","year":"2009","journal-title":"Laryngoscope"},{"issue":"01","key":"ref27","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1148\/radiology.216.1.r00jl4519","article-title":"Major salivary gland imaging","volume":"216","author":"D M Yousem","year":"2000","journal-title":"Radiology"},{"issue":"04","key":"ref28","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/RUQ.0b013e3182a0abe0","article-title":"High-frequency ultrasound in parotid gland disease","volume":"29","author":"P M Onkar","year":"2013","journal-title":"Ultrasound Q"},{"issue":"03","key":"ref29","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1002\/lary.22452","article-title":"Diagnosis and gland-preserving minimally invasive therapy for Wharton's duct stenoses","volume":"122","author":"M Koch","year":"2012","journal-title":"Laryngoscope"},{"issue":"05","key":"ref30","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.stomax.2011.08.017","article-title":"[Cone beam 3D sialography: preliminary study]","volume":"112","author":"A Varoquaux","year":"2011","journal-title":"Rev Stomatol Chir Maxillofac"},{"key":"ref31","volume-title":"Development and Application of a Technique for Three-Dimensional Sialography Using Cone Beam Computed Tomography","author":"F M Jadu","year":"2012"},{"issue":"08","key":"ref32","first-page":"878","article-title":"The anatomical pattern of ductal arborization in parotid glands using cone-beam computerized sialography","volume":"37","author":"T Amiel","year":"2024","journal-title":"Clin Anat"},{"issue":"08","key":"ref33","doi-asserted-by":"crossref","first-page":"1868","DOI":"10.3390\/diagnostics12081868","article-title":"Anatomical features of the parotid duct in sialography as an aid to endoscopy - a retrospective study","volume":"12","author":"G Avishai","year":"2022","journal-title":"Diagnostics (Basel)"}],"container-title":["Indian Journal of Radiology and Imaging"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-0045-1811209.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T22:34:09Z","timestamp":1782254049000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-0045-1811209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,22]]},"references-count":33,"journal-issue":{"issue":"03","published-online":{"date-parts":[[2026,6,23]]},"published-print":{"date-parts":[[2026,7]]}},"URL":"https:\/\/doi.org\/10.1055\/s-0045-1811209","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0971-3026","1998-3808"],"issn-type":[{"value":"0971-3026","type":"print"},{"value":"1998-3808","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,22]]}}}