{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T09:13:02Z","timestamp":1760865182249},"reference-count":27,"publisher":"Georg Thieme Verlag KG","issue":"05","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Handchir Mikrochir Plast Chir"],"published-print":{"date-parts":[[2005,10]]},"abstract":"<jats:p>In einer retrospektiven Studie berichtet der Autor \u00fcber die vorl\u00e4ufigen Ergebnisse von Fingerreplantationen, die an der Abteilung f\u00fcr Unfallchirurgie, Orthop\u00e4die und Handchirurgie des Central Hospital 108, No. 1 Tran Hung Dao, Hanoi, Vietnam, zwischen September 1999 und Dezember 2002 durchgef\u00fchrt wurden. 46 amputierte Finger, davon 32 komplett und 14 subtotal amputiert, wurden replantiert und nachuntersucht. Die Mehrheit der Amputationen wurde durch Quetschverletzungen (76 %) verursacht, wobei vorwiegend die linke Hand betroffen war (78,3 %). Die Erfolgsrate betrug 91,3 %. Sekund\u00e4roperationen wurden bei acht von 42 erhaltenen Fingern (19 %) durchgef\u00fchrt, davon sieben Tenolysen und eine Reosteosynthese. Das funktionelle Ergebnis war in 90,5 % der F\u00e4lle als \u201e gut\u201c oder \u201ezufriedenstellend\u201c einzustufen bei einer durchschnittlichen Nachbeobachtungszeit von 18 Monaten. Ein replantierter Finger musste\n      nach einem Jahr wegen Funktionslosigkeit und Missempfindungen amputiert werden. Wir schlie\u00dfen aus dieser Studie, dass Fingerreplantationen, insbesondere bei multiplen Amputationen, oft erfolgreich sind und der Versuch sich stets lohnt, sowohl die Funktion als auch die normale Erscheinung von Hand und Fingern wiederherzustellen. Trotz eingeschr\u00e4nkter postoperativer Beweglichkeit und reduzierter Sensibilit\u00e4t im Vergleich zu unverletzten Fingern k\u00f6nnen die meisten Patienten mit erhaltenen replantierten Fingern nach Amputationsverletzungen aktiv und effektiv normale T\u00e4tigkeiten ohne Schmerzen oder Instabilit\u00e4t ausf\u00fchren.<\/jats:p>","DOI":"10.1055\/s-2005-872848","type":"journal-article","created":{"date-parts":[[2005,11,14]],"date-time":"2005-11-14T14:30:32Z","timestamp":1131978632000},"page":"337-343","source":"Crossref","is-referenced-by-count":6,"title":["Microsurgical Finger Replantation in Hanoi, Vietnam: Our First Experience"],"prefix":"10.1055","volume":"37","author":[{"given":"Nguyen The","family":"Hoang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"194","published-online":{"date-parts":[[2005,11,14]]},"reference":[{"key":"ref1","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1097\/00000637-200106000-00006","article-title":"Fingertip replantation at or distal to the nail base: Use of the technique of artery-only anastomosis","volume":"46","author":"M Aky\u00fcrek","year":"2001","journal-title":"Ann Plast Surg"},{"key":"ref2","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1054\/jhsb.2001.0642","article-title":"A new technique to salvage digital replantation with compromised venous outflow","volume":"26","author":"M M Al-Qattan","year":"2001","journal-title":"J Hand Surg [Br]"},{"key":"ref3","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1097\/01.SAP.0000037269.62980.69","article-title":"Heterotopic replantation in mutilating hand injury","volume":"50","author":"P C An","year":"2003","journal-title":"Ann Plast Surg"},{"key":"ref4","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/0007-1226(92)90202-9","article-title":"Ten-digit and nine-digit replantation (4 cases)","volume":"45","author":"S M Baek","year":"1992","journal-title":"Br J Plast Surg"},{"key":"ref7","doi-asserted-by":"crossref","first-page":"216","DOI":"10.1097\/00005373-199402000-00013","article-title":"A technique for simultaneous replantation of multiple amputated digits at Tamai's zone V","volume":"36","author":"H Y Chiu","year":"1994","journal-title":"J Trauma"},{"key":"ref8","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1097\/00000637-199805000-00018","article-title":"Late digital replantation failure: Pathophysiology and risk factors","volume":"40","author":"F J Duffy","year":"1998","journal-title":"Ann Plast Surg"},{"key":"ref9","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1097\/01.PRS.0000037758.54135.4B","article-title":"Adjacent and spontaneous neurotization after distal digital replantation in children","volume":"111","author":"S Faivre","year":"2003","journal-title":"Plast Reconstr Surg"},{"key":"ref10","doi-asserted-by":"crossref","first-page":"551","DOI":"10.1097\/00005373-198107000-00009","article-title":"Upper extremity replantation: current concepts and patient selection","volume":"21","author":"A H Gold","year":"1981","journal-title":"J Trauma"},{"key":"ref11","first-page":"414","article-title":"Replantationen: Indikation und Organisationsstruktur","volume":"27","author":"P Hahn","year":"1998","journal-title":"Orthop\u00e4de"},{"key":"ref12","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1097\/01.PRS.0000046497.88549.E0","article-title":"Significance of venous anastomosis in fingertip replantation","volume":"111","author":"Y Hattori","year":"2003","journal-title":"Plast Reconstr Surg"},{"key":"ref13","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/00006534-199609000-00018","article-title":"Eight cases of nine-digit and ten-digit replantations","volume":"98","author":"W K Kim","year":"1996","journal-title":"Plast Reconstr Surg"},{"key":"ref14","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1097\/00006534-196810000-00021","article-title":"Successful replantation of a completely cut-off thumb: case report","volume":"42","author":"S Komasu","year":"1968","journal-title":"Plast Reconstr Surg"},{"key":"ref15","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1097\/00000637-200044030-00007","article-title":"The effects of the number and ratio of repaired arteries and veins on the survival rate in digital replantation","volume":"44","author":"B Lee","year":"2000","journal-title":"Ann Plast Surg"},{"key":"ref16","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1097\/00006534-199608000-00023","article-title":"Successful replantation in 10-digit complete amputation","volume":"98","author":"Q T Li","year":"1996","journal-title":"Plast Reconstr Surg"},{"key":"ref17","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1097\/00006534-198610000-00017","article-title":"Seven-digit replantation: digit survival after 39 hours of cold ischemia","volume":"78","author":"J W May","year":"1986","journal-title":"Plast Reconstr Surg"},{"key":"ref18","first-page":"26","article-title":"Digital replantation: Clinical experiences","volume":"133","author":"A M McLeod","year":"1978","journal-title":"Clin Orthop"},{"key":"ref19","doi-asserted-by":"crossref","first-page":"512","DOI":"10.1016\/S0266-7681(00)80026-1","article-title":"Survival factors in digital replantation: significance of postoperative anaemia","volume":"25","author":"H Niibayashi","year":"2000","journal-title":"J Hand Surg [Br]"},{"key":"ref20","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1097\/00006534-197311000-00003","article-title":"Clinical replantation of digits","volume":"52","author":"B M O'Brien","year":"1973","journal-title":"Plast Reconstr Surg"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/S0266-7681(98)80005-3","article-title":"Distal digital replantations and revascularizations: 237 digits in 192 patients","volume":"23","author":"A Patradul","year":"1998","journal-title":"J Hand Surg [Br]"},{"key":"ref22","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/01.SAP.0000058499.74279.D8","article-title":"Tendon function after replantation: prognostic factors and strategies to enhance total active motion","volume":"51","author":"D Ross","year":"2003","journal-title":"Ann Plast Surg"},{"key":"ref23","doi-asserted-by":"crossref","first-page":"12","DOI":"10.3109\/17453679509157157","article-title":"Current indications for single digit replantation","volume":"264","author":"P N Soucacos","year":"1995","journal-title":"Acta Orthop Scand"},{"key":"ref24","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1054\/jhsb.2001.0595","article-title":"Indications and selection for digital amputation and replantation","volume":"26","author":"P N Soucacos","year":"2001","journal-title":"J Hand Surg [Br]"},{"key":"ref25","first-page":"106","article-title":"Microvascular anastomosis and its application on the replantation of amputated digits and hands","volume":"133","author":"S Tamai","year":"1978","journal-title":"Clin Orthop"},{"key":"ref26","first-page":"186","article-title":"Detaillierte Beschreibung einer prim\u00e4ren Beugsehnennaht im Digitalkanal","volume":"8","author":"C Verdan","year":"1981","journal-title":"Handchirurgie"},{"key":"ref27","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1097\/00006534-198808000-00026","article-title":"Three successful digital replantations in a patient after 84, 86 and 94 hours of cold ischemia time","volume":"82","author":"F C Wei","year":"1988","journal-title":"Plast Reconstr Surg"},{"key":"ref28","first-page":"195","article-title":"Replantation of digits and hands","volume":"133","author":"A J Weiland","year":"1978","journal-title":"Clin Orthop"},{"key":"ref29","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1016\/S0007-1226(03)00033-X","article-title":"Secondary procedures following digital replantation and revascularisation","volume":"56","author":"J C Yu","year":"2003","journal-title":"Br J Plast Surg"}],"container-title":["Handchirurgie \u00b7 Mikrochirurgie \u00b7 Plastische Chirurgie"],"original-title":[],"language":"de","link":[{"URL":"http:\/\/www.thieme-connect.de\/products\/ejournals\/pdf\/10.1055\/s-2005-872848.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,19]],"date-time":"2022-10-19T00:09:04Z","timestamp":1666138144000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.thieme-connect.de\/DOI\/DOI?10.1055\/s-2005-872848"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,10]]},"references-count":27,"journal-issue":{"issue":"05","published-online":{"date-parts":[[2005,11,14]]},"published-print":{"date-parts":[[2005,10]]}},"URL":"https:\/\/doi.org\/10.1055\/s-2005-872848","archive":["Portico","CLOCKSS"],"relation":{},"ISSN":["0722-1819","1439-3980"],"issn-type":[{"value":"0722-1819","type":"print"},{"value":"1439-3980","type":"electronic"}],"subject":[],"published":{"date-parts":[[2005,10]]}}}