{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T18:13:52Z","timestamp":1779905632422,"version":"3.53.1"},"reference-count":24,"publisher":"AIP Publishing","issue":"7","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2013,7,1]]},"abstract":"<jats:p>Electronic transformers are widely used in power systems because of their wide bandwidth and good transient performance. However, as an emerging technology, the failure rate of electronic transformers is higher than that of traditional transformers. As a result, the calibration period needs to be shortened. Traditional calibration methods require the power of transmission line be cut off, which results in complicated operation and power off loss. This paper proposes an online calibration system which can calibrate electronic current transformers without power off. In this work, the high accuracy standard current transformer and online operation method are the key techniques. Based on the clamp-shape iron-core coil and clamp-shape air-core coil, a combined clamp-shape coil is designed as the standard current transformer. By analyzing the output characteristics of the two coils, the combined clamp-shape coil can achieve verification of the accuracy. So the accuracy of the online calibration system can be guaranteed. Moreover, by employing the earth potential working method and using two insulating rods to connect the combined clamp-shape coil to the high voltage bus, the operation becomes simple and safe. Tests in China National Center for High Voltage Measurement and field experiments show that the proposed system has a high accuracy of up to 0.05 class.<\/jats:p>","DOI":"10.1063\/1.4815831","type":"journal-article","created":{"date-parts":[[2013,7,22]],"date-time":"2013-07-22T22:19:34Z","timestamp":1374531574000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":19,"title":["An accurate online calibration system based on combined clamp-shape coil for high voltage electronic current transformers"],"prefix":"10.1063","volume":"84","author":[{"given":"Zhen-hua","family":"Li","sequence":"first","affiliation":[{"name":"Huazhong University of Science and Technology 1 CEEE of , Wuhan 430074, China"},{"name":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology 2 , Wuhan 430074, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-bin","family":"Li","sequence":"additional","affiliation":[{"name":"Huazhong University of Science and Technology 1 CEEE of , Wuhan 430074, China"},{"name":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology 2 , Wuhan 430074, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi","family":"Zhang","sequence":"additional","affiliation":[{"name":"Huazhong University of Science and Technology 1 CEEE of , Wuhan 430074, China"},{"name":"State Key Laboratory of Advanced Electromagnetic Engineering and Technology 2 , Wuhan 430074, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2013,7,22]]},"reference":[{"key":"2023070415273460600_c1","doi-asserted-by":"publisher","first-page":"112001","DOI":"10.1088\/0957-0233\/21\/11\/112001","volume":"21","year":"2010","journal-title":"Meas. Sci. Technol."},{"key":"2023070415273460600_c2","first-page":"246","volume-title":"Proceedings of the Seventh International Conference on Electronic Measurement & Instruments","year":"2008"},{"issue":"6","key":"2023070415273460600_c3","doi-asserted-by":"publisher","first-page":"2007","DOI":"10.1109\/TIM.2011.2115650","volume":"60","year":"2011","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"6","key":"2023070415273460600_c4","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1109\/63.803407","volume":"14","year":"1999","journal-title":"IEEE Trans. Power Electron."},{"issue":"7","key":"2023070415273460600_c5","doi-asserted-by":"publisher","first-page":"960","DOI":"10.1016\/j.measurement.2010.04.001","volume":"43","year":"2010","journal-title":"Measurement"},{"issue":"5","key":"2023070415273460600_c6","doi-asserted-by":"publisher","first-page":"1345","DOI":"10.1109\/TIM.2008.2009184","volume":"58","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"2","key":"2023070415273460600_c7","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1109\/19.918121","volume":"50","year":"2001","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"4","key":"2023070415273460600_c8","doi-asserted-by":"publisher","first-page":"1054","DOI":"10.1109\/TIM.2008.2007031","volume":"58","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"2","key":"2023070415273460600_c9","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1109\/TIM.2004.843420","volume":"54","year":"2005","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"2023070415273460600_c10","doi-asserted-by":"publisher","first-page":"065111","DOI":"10.1063\/1.4729475","volume":"83","year":"2012","journal-title":"Rev. Sci. Instrum."},{"key":"2023070415273460600_c11","first-page":"1","volume-title":"Proceedings of the 6th IEEE\/PES Transmission and Distribution","year":"2012"},{"key":"2023070415273460600_c12","first-page":"379","volume-title":"Proceedings of the 16th IEEE\/PES Transmission and Distribution Conference and Exposition","year":"2001"},{"issue":"2","key":"2023070415273460600_c13","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1109\/19.492764","volume":"45","year":"1996","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"2023070415273460600_c14","first-page":"705","volume-title":"Proceedings of the 2001 IEEE Power Engineering Society Winter Meeting","year":"2001"},{"issue":"1","key":"2023070415273460600_c15","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1109\/TPS.2011.2173806","volume":"40","year":"2012","journal-title":"IEEE Trans. Plasma Sci."},{"key":"2023070415273460600_c16","doi-asserted-by":"publisher","first-page":"025107","DOI":"10.1063\/1.3523341","volume":"82","year":"2011","journal-title":"Rev. Sci. Instrum."},{"key":"2023070415273460600_c17","first-page":"65","year":"2002"},{"key":"2023070415273460600_c18","first-page":"2","year":"2010"},{"issue":"1","key":"2023070415273460600_c19","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1109\/TIM.2008.928412","volume":"58","year":"2009","journal-title":"IEEE Trans. Instrum. Meas."},{"issue":"6","key":"2023070415273460600_c20","doi-asserted-by":"publisher","first-page":"065107","DOI":"10.1063\/1.1921427","volume":"76","year":"2005","journal-title":"Rev. Sci. Instrum."},{"key":"2023070415273460600_c21","first-page":"3083","volume-title":"Proceedings of the 2000 IEEE Industry Applications Conference","year":"2000"},{"issue":"4","key":"2023070415273460600_c22","first-page":"66","volume":"23","year":"2008","journal-title":"Trans. China Electrotech. Soc."},{"issue":"4","key":"2023070415273460600_c23","doi-asserted-by":"publisher","first-page":"1204","DOI":"10.1109\/TIM.2006.876526","volume":"55","year":"2006","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"2023070415273460600_c24","first-page":"3","year":"2008"}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4815831\/13519224\/075113_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4815831\/13519224\/075113_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T19:19:03Z","timestamp":1688498343000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/84\/7\/075113\/360507\/An-accurate-online-calibration-system-based-on"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,7,1]]},"references-count":24,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2013,7,1]]}},"URL":"https:\/\/doi.org\/10.1063\/1.4815831","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2013,7]]},"published":{"date-parts":[[2013,7,1]]},"article-number":"075113"}}