{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T11:08:07Z","timestamp":1753873687249,"version":"3.41.2"},"reference-count":14,"publisher":"AIP Publishing","issue":"8","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2016,8,1]]},"abstract":"<jats:p>We describe a microfluidic Coriolis effect flowmeter that is simple to assemble, operates at elevated temperature and pressure, and can be operated with a lock-in amplifier. The sensor has a flow rate sensitivity greater than 2\u00b0 of phase shift per 1 g\/min of mass flow and is benchmarked with flow rates ranging from 0.05 to 2.0 g\/min. The internal volume is 15 \u03bcl and uses off-the-shelf optical components to measure the tube motion. We demonstrate that fluid density can be calculated from the frequency of the resonating element with proper calibration.<\/jats:p>","DOI":"10.1063\/1.4960173","type":"journal-article","created":{"date-parts":[[2016,8,9]],"date-time":"2016-08-09T17:00:45Z","timestamp":1470762045000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":7,"title":["A simple microfluidic Coriolis effect flowmeter for operation at high pressure and high temperature"],"prefix":"10.1063","volume":"87","author":[{"given":"Christopher","family":"Harrison","sequence":"first","affiliation":[{"name":"Schlumberger-Doll Research , 1 Hampshire Street, Cambridge, Massachusetts 02139, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacques","family":"Jundt","sequence":"additional","affiliation":[{"name":"Schlumberger-Doll Research , 1 Hampshire Street, Cambridge, Massachusetts 02139, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"317","published-online":{"date-parts":[[2016,8,8]]},"reference":[{"key":"2023072721214106800_c1","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1016\/0955-5986(94)90027-2","volume":"5","year":"1994","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c2","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.flowmeasinst.2014.08.015","volume":"40","year":"2014","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c3","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1016\/j.flowmeasinst.2006.07.004","volume":"17","year":"2006","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c4","first-page":"225","article-title":"Flow Measurement, Mass Flowmeters, Coriolis","volume-title":"Instrument Engineers\u2019 Handbook, Process Measurement and Analysis","author":"Liptak","year":"2003"},{"key":"2023072721214106800_c5","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1016\/S0955-5986(01)00031-0","volume":"12","year":"2002","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c6","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.flowmeasinst.2006.07.006","volume":"17","year":"2006","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c7","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.flowmeasinst.2014.03.009","volume":"37","year":"2014","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c8","unstructured":"L.\u2008Gao, T. v.\u2008Zuilekom, M.\u2008Pelletier, M.\u2008Proett, S.\u2008Eyuboglu, B.\u2008Engeleman, H.\u2008Elshawawi, and M.\u2008Howes, SPE papers Nos. 133405 and 126046, 2010."},{"key":"2023072721214106800_c9"},{"year":"2003","key":"2023072721214106800_c10","first-page":"90"},{"key":"2023072721214106800_c11","doi-asserted-by":"publisher","first-page":"325","DOI":"10.1016\/j.flowmeasinst.2006.06.003","volume":"17","year":"2006","journal-title":"Flow Meas. Instrum."},{"key":"2023072721214106800_c12","unstructured":"A.\u2008Mehendale, \u201cCoriolis mass flow rate meters for low flows,\u201d Ph.D. thesis, University of Twente, 2008."},{"key":"2023072721214106800_c13","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1088\/0957-0233\/3\/8\/002","volume":"3","year":"1992","journal-title":"Meas. Sci. Technol."},{"key":"2023072721214106800_c14","doi-asserted-by":"publisher","first-page":"105101","DOI":"10.1063\/1.3226668","volume":"80","year":"2009","journal-title":"Rev. Sci. Instrum."}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4960173\/16096416\/085002_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4960173\/16096416\/085002_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,27]],"date-time":"2023-07-27T21:22:12Z","timestamp":1690492932000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/87\/8\/085002\/843753\/A-simple-microfluidic-Coriolis-effect-flowmeter"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,1]]},"references-count":14,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2016,8,1]]}},"URL":"https:\/\/doi.org\/10.1063\/1.4960173","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"type":"print","value":"0034-6748"},{"type":"electronic","value":"1089-7623"}],"subject":[],"published-other":{"date-parts":[[2016,8]]},"published":{"date-parts":[[2016,8,1]]},"article-number":"085002"}}