{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T20:21:44Z","timestamp":1772655704093,"version":"3.50.1"},"reference-count":16,"publisher":"AIP Publishing","issue":"8","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2020,8,1]]},"abstract":"<jats:p>A portable device for cleaning and ozone sterilization of small-sized delicate dental instruments that cannot withstand the high heat and humidity of standard autoclaving has been developed. The device contains a remote unit for magnetic mechanical washing, an ultrasonic bath for pre-cleaning treatment, and a container for ozone sterilization with a reactor based on dielectric barrier discharge. The maximum ozone concentration in water reached 8.5 mg\/l for 10 min of operation at a water temperature of 19 \u00b0C. The results of inactivation of Pseudomonas aeruginosa, Escherichia coli, and Staphylococcus aureus are presented. Distilled water with such seeded micro-organisms was bubbled with an ozone\u2013air mixture at an ozone concentration of 5.8 mg\/l at 17 \u00b0C for 5 min, 10 min, 20 min, and 30 min. The maximum bactericidal effect was manifested for Pseudomonas aeruginosa cells with their total elimination within 10 min. Inactivation of Escherichia coli bacteria was monitored after 20 min of treatment, and Staphylococcus aureus\u2014after 30 min of treatment.<\/jats:p>","DOI":"10.1063\/1.5145279","type":"journal-article","created":{"date-parts":[[2020,8,20]],"date-time":"2020-08-20T13:14:29Z","timestamp":1597929269000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":15,"title":["Portable ozone sterilization device with mechanical and ultrasonic cleaning units for dentistry"],"prefix":"10.1063","volume":"91","author":[{"given":"Valerij","family":"Taran","sequence":"first","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6538-6862","authenticated-orcid":false,"given":"Igor","family":"Garkusha","sequence":"additional","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"},{"name":"V.N. Karazin Kharkiv National University 2 , 61022 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuriy","family":"Gnidenko","sequence":"additional","affiliation":[{"name":"V.N. Karazin Kharkiv National University 2 , 61022 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Viktor","family":"Krasnyj","sequence":"additional","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9491-5276","authenticated-orcid":false,"given":"Alina","family":"Lozina","sequence":"additional","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8903-1484","authenticated-orcid":false,"given":"Anton","family":"Taran","sequence":"additional","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oleg","family":"Chechelnitskyi","sequence":"additional","affiliation":[{"name":"Institute of Plasma Physics of NSC KIPT 1 , 61108 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8291-2721","authenticated-orcid":false,"given":"Vadym","family":"Starikov","sequence":"additional","affiliation":[{"name":"National Technical University \u201cKharkov Polytechnic Institute\u201d 3 , 61002 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Svetlana","family":"Starikova","sequence":"additional","affiliation":[{"name":"Kharkov Medical Academy of Post-Graduate Education 4 , 61022 Kharkov, Ukraine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"317","published-online":{"date-parts":[[2020,8,20]]},"reference":[{"issue":"8","key":"2023080500543112600_c1","first-page":"604","article-title":"Disinfection and sterilization in dentistry","volume":"131","year":"2014","journal-title":"Tex. Dent. J."},{"key":"2023080500543112600_c2","doi-asserted-by":"publisher","first-page":"6507286","DOI":"10.1155\/2019\/6507286","article-title":"Sterilisation in dentistry: A review of the literature","volume":"2019","journal-title":"Int. J. Dent."},{"issue":"5","key":"2023080500543112600_c3","doi-asserted-by":"publisher","first-page":"232","DOI":"10.23736\/S0026-4970.17.04087-0","article-title":"How to manage the biological risk in a dental clinic: Current and future perspectives","volume":"66","year":"2017","journal-title":"J. Minerva Stomatol."},{"issue":"2","key":"2023080500543112600_c4","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3947\/ic.2018.50.2.101","article-title":"Review of disinfection and sterilization\u2013back to the basics","volume":"50","year":"2018","journal-title":"Infect. Chemother."},{"key":"2023080500543112600_c5","first-page":"426","volume-title":"Fundamental Aspects of Microbial Resistance to Chemical and Physical Agents. Sterilization of Medical Products","year":"1991"},{"key":"2023080500543112600_c6","doi-asserted-by":"publisher","first-page":"1355","DOI":"10.1016\/s0043-1354(96)00394-6","article-title":"Kinetics of Escherichia coli inactivation with ozone","volume":"31","year":"1997","journal-title":"Water Res."},{"key":"2023080500543112600_c7","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/j.jiph.2011.12.007","article-title":"Antimicrobial effects of ozonated water on the sanitization of dental instruments contaminated with E. coli, S. aureus, C. albicans, or the spores of B. atrophaeus","volume":"5","year":"2012","journal-title":"J. Infect. Public Health"},{"key":"2023080500543112600_c8","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1002\/ppap.200900076","article-title":"Influence of the air humidity on the reduction of bacillus spores in a defined environment at atmospheric pressure using a dielectric barrier surface discharge","volume":"7","year":"2010","journal-title":"Plasma Processes Polym."},{"key":"2023080500543112600_c9","doi-asserted-by":"publisher","first-page":"100","DOI":"10.34343\/ijpest.2008.02.02.100","article-title":"Sterilization using a wide-gap discharge under atmospheric pressure","volume":"2","year":"2008","journal-title":"Int. J. Plasma Environ. Sci. Technol."},{"key":"2023080500543112600_c10","doi-asserted-by":"publisher","first-page":"7065","DOI":"10.1016\/j.apsusc.2011.03.014","article-title":"The sterilization of Escherichia coli by dielectric-barrier discharge plasma at atmospheric pressure","volume":"257","year":"2011","journal-title":"Appl. Surf. Sci."},{"key":"2023080500543112600_c11"},{"issue":"2","key":"2023080500543112600_c12","first-page":"277","article-title":"Recent developments of plasma-based technologies for medicine and industry","volume":"57","year":"2012","journal-title":"Nukleonika"},{"key":"2023080500543112600_c13","first-page":"230","article-title":"Devices for pre-sterilization treatment of endoscopes by ozone and ultrasound","volume-title":"Problems of Atomic Science and Technology","year":"2014"},{"key":"2023080500543112600_c14","first-page":"93","article-title":"Hardware\u2013software complex for the diagnosis of ozone sterilizers","volume":"4","year":"2011","journal-title":"Electron. Commun."},{"issue":"1","key":"2023080500543112600_c15","first-page":"149","article-title":"Low-temperature ozone sterilizer based on reactor with electrolytic cell","volume":"2019","journal-title":"Probl. Atomic Sci. Technol."},{"issue":"1","key":"2023080500543112600_c16","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1615\/hightempmatproc.2019029940","article-title":"Development of ozone generator based on dielectric barrier discharge for water treatment","volume":"23","year":"2019","journal-title":"High Temp. Mater. Processes"}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.5145279\/16025791\/084105_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.5145279\/16025791\/084105_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,5]],"date-time":"2023-08-05T00:54:44Z","timestamp":1691196884000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/91\/8\/084105\/990275\/Portable-ozone-sterilization-device-with"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,1]]},"references-count":16,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2020,8,1]]}},"URL":"https:\/\/doi.org\/10.1063\/1.5145279","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2020,8]]},"published":{"date-parts":[[2020,8,1]]},"article-number":"084105"}}