{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,21]],"date-time":"2026-02-21T10:57:18Z","timestamp":1771671438080,"version":"3.50.1"},"reference-count":20,"publisher":"AIP Publishing","issue":"8","license":[{"start":{"date-parts":[[2021,8,25]],"date-time":"2021-08-25T00:00:00Z","timestamp":1629849600000},"content-version":"vor","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,8,25]],"date-time":"2021-08-25T00:00:00Z","timestamp":1629849600000},"content-version":"tdm","delay-in-days":24,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,8,1]]},"abstract":"<jats:p>The transport of virus-laden aerosols from a host to a susceptible person is governed by complex turbulent airflow and physics related to breathing, coughing and sneezing, mechanical and passive ventilation, thermal buoyancy effects, surface deposition, masks, and air filtration. In this paper, we study the infection risk via airborne transmission on an urban bus using unsteady Reynolds-averaged Navier\u2013Stokes equations and a passive-scalar model of the virus-laden aerosol concentration. Results from these simulations are directly compared to the widely used well-mixed model and show significant differences in the concentration field and number of inhaled particles. Specifically, in the limit of low mechanical ventilation rates, the well-mixed model will overpredict the concentration far from the infected passenger and substantially underpredict the concentration near the infected passenger. The results reported herein also apply to other enclosed spaces.<\/jats:p>","DOI":"10.1063\/5.0061219","type":"journal-article","created":{"date-parts":[[2021,8,25]],"date-time":"2021-08-25T15:21:26Z","timestamp":1629904886000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":11,"title":["On the utility of a well-mixed model for predicting disease transmission on an urban bus"],"prefix":"10.1063","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9398-072X","authenticated-orcid":false,"given":"Zhihang","family":"Zhang","sequence":"first","affiliation":[{"name":"Department of Naval Architecture and Marine Engineering, University of Michigan 1 , Ann Arbor, Michigan 48109-2145, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1684-4967","authenticated-orcid":false,"given":"Jesse","family":"Capecelatro","sequence":"additional","affiliation":[{"name":"Department of Mechanical Engineering, University of Michigan 2 , Ann Arbor, Michigan 48109-2145, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7286-7402","authenticated-orcid":false,"given":"Kevin","family":"Maki","sequence":"additional","affiliation":[{"name":"Department of Naval Architecture and Marine Engineering, University of Michigan 1 , Ann Arbor, Michigan 48109-2145, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"317","published-online":{"date-parts":[[2021,8,25]]},"reference":[{"key":"2024031516535077200_c1","doi-asserted-by":"publisher","first-page":"e2018995118","DOI":"10.1073\/pnas.2018995118","article-title":"A guideline to limit indoor airborne transmission of COVID-19","volume":"118","year":"2021","journal-title":"Proc. Natl. Acad. Sci."},{"key":"2024031516535077200_c2","doi-asserted-by":"publisher","first-page":"063303","DOI":"10.1063\/5.0015044","article-title":"On respiratory droplets and face masks","volume":"32","year":"2020","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c3","doi-asserted-by":"publisher","first-page":"011905","DOI":"10.1063\/5.0038180","article-title":"On airborne virus transmission in elevators and confined spaces","volume":"33","year":"2021","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c4","doi-asserted-by":"publisher","first-page":"035122","DOI":"10.1063\/5.0042086","article-title":"Direct numerical simulation of the turbulent flow generated during a violent expiratory event","volume":"33","year":"2021","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c5","doi-asserted-by":"publisher","first-page":"102719","DOI":"10.1016\/j.scs.2021.102719","article-title":"Assessing and controlling infection risk with Wells-Riley model and spatial flow impact factor (SFIF)","volume":"67","year":"2021","journal-title":"Sustainable Cities Soc."},{"key":"2024031516535077200_c6","doi-asserted-by":"publisher","first-page":"033109","DOI":"10.1103\/physreve.103.033109","article-title":"Superspreading events suggest aerosol transmission of SARS-CoV-2 by accumulation in enclosed spaces","volume":"103","year":"2021","journal-title":"Phys. Rev. E"},{"key":"2024031516535077200_c7","article-title":"Predicting the spatially varying infection risk in indoor spaces using an efficient airborne transmission model","year":"2021"},{"key":"2024031516535077200_c8","first-page":"96","article-title":"The numerical computation of turbulent flows","volume-title":"Numerical Prediction of Flow, Heat Transfer, Turbulence and Combustion","year":"1983"},{"key":"2024031516535077200_c9","doi-asserted-by":"publisher","first-page":"9826","DOI":"10.1038\/s41598-021-89078-7","article-title":"Peering inside a cough or sneeze to explain enhanced airborne transmission under dry weather","volume":"11","year":"2021","journal-title":"Sci. Rep."},{"key":"2024031516535077200_c10","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1111\/ina.12751","article-title":"Transmission of SARS-CoV-2 by inhalation of respiratory aerosol in the Skagit Valley Chorale superspreading event","volume":"31","year":"2021","journal-title":"Indoor Air"},{"key":"2024031516535077200_c11","doi-asserted-by":"publisher","first-page":"101903","DOI":"10.1063\/5.0025476","article-title":"A mathematical framework for estimating risk of airborne transmission of COVID-19 with application to face mask use and social distancing","volume":"32","year":"2020","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c12","doi-asserted-by":"publisher","first-page":"043311","DOI":"10.1063\/5.0048746","article-title":"Role of pulsatility on particle dispersion in expiratory flows","volume":"33","year":"2021","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c13","doi-asserted-by":"publisher","first-page":"105832","DOI":"10.1016\/j.envint.2020.105832","article-title":"How can airborne transmission of COVID-19 indoors be minimised?","volume":"142","year":"2020","journal-title":"Environ. Int."},{"key":"2024031516535077200_c14","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1093\/oxfordjournals.aje.a112560","article-title":"Airborne spread of measles in a suburban elementary school","volume":"107","year":"1978","journal-title":"Am. J. Epidemiol."},{"key":"2024031516535077200_c15","doi-asserted-by":"publisher","first-page":"2932","DOI":"10.3390\/ijerph17082932","article-title":"Airborne transmission route of COVID-19: Why 2 meters\/6 feet of inter-personal distance could not be enough","volume":"17","year":"2020","journal-title":"Int. J. Environ. Res. Public Health"},{"key":"2024031516535077200_c16","doi-asserted-by":"publisher","first-page":"1665","DOI":"10.1001\/jamainternmed.2020.5225","article-title":"Community outbreak investigation of SARS-CoV-2 transmission among bus riders in Eastern China","volume":"180","year":"2020","journal-title":"JAMA Intern. Med."},{"key":"2024031516535077200_c17","doi-asserted-by":"publisher","first-page":"033312","DOI":"10.1063\/5.0044720","article-title":"Simulation of aerosol transmission on a Boeing 737 airplane with intervention measures for COVID-19 mitigation","volume":"33","year":"2021","journal-title":"Phys. Fluids"},{"key":"2024031516535077200_c18","doi-asserted-by":"publisher","first-page":"104866","DOI":"10.1016\/j.ssci.2020.104866","article-title":"Modelling aerosol transport and virus exposure with numerical simulations in relation to SARS-CoV-2 transmission by inhalation indoors","volume":"130","year":"2020","journal-title":"Saf. Sci."},{"key":"2024031516535077200_c19","doi-asserted-by":"publisher","first-page":"14857","DOI":"10.1073\/pnas.2009637117","article-title":"Identifying airborne transmission as the dominant route for the spread of COVID-19","volume":"117","year":"2020","journal-title":"Proc. Natl. Acad. Sci."},{"key":"2024031516535077200_c20","doi-asserted-by":"publisher","first-page":"015116","DOI":"10.1063\/5.0037452","article-title":"Disease transmission through expiratory aerosols on an urban bus","volume":"33","year":"2021","journal-title":"Phys. Fluids"}],"container-title":["AIP Advances"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/adv\/article-pdf\/doi\/10.1063\/5.0061219\/19733208\/085229_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/pubs.aip.org\/aip\/adv\/article-pdf\/doi\/10.1063\/5.0061219\/19733208\/085229_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/adv\/article-pdf\/doi\/10.1063\/5.0061219\/19733208\/085229_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T19:24:17Z","timestamp":1748978657000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/adv\/article\/11\/8\/085229\/968148\/On-the-utility-of-a-well-mixed-model-for"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,8,1]]},"references-count":20,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2021,8,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0061219","relation":{},"ISSN":["2158-3226"],"issn-type":[{"value":"2158-3226","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2021,8]]},"published":{"date-parts":[[2021,8,1]]},"article-number":"085229"}}