{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T22:24:04Z","timestamp":1787005444871,"version":"build-2736575974"},"reference-count":75,"publisher":"AIP Publishing","issue":"7","funder":[{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","award":["DOE-FG02-99ER45742"],"award-info":[{"award-number":["DOE-FG02-99ER45742"]}],"id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000936","name":"Gordon and Betty Moore Foundation","doi-asserted-by":"publisher","award":["GBMF9453"],"award-info":[{"award-number":["GBMF9453"]}],"id":[{"id":"10.13039\/100000936","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["NSF-MRI 1337871"],"award-info":[{"award-number":["NSF-MRI 1337871"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,7,1]]},"abstract":"<jats:p>To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM\u2019s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to \u03bcm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a \u03bcm-sized 2D sample.<\/jats:p>","DOI":"10.1063\/5.0204940","type":"journal-article","created":{"date-parts":[[2024,7,3]],"date-time":"2024-07-03T09:38:29Z","timestamp":1719999509000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":7,"title":["Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers"],"prefix":"10.1063","volume":"95","author":[{"ORCID":"https:\/\/orcid.org\/0009-0006-4819-2955","authenticated-orcid":false,"given":"Angela M.","family":"Coe","sequence":"first","affiliation":[{"name":"Department of Physics and Astronomy, Rutgers, The State University of New Jersey , Piscataway, New Jersey 08854, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-5442-8939","authenticated-orcid":false,"given":"Guohong","family":"Li","sequence":"additional","affiliation":[{"name":"Department of Physics and Astronomy, Rutgers, The State University of New Jersey , Piscataway, New Jersey 08854, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2516-2749","authenticated-orcid":false,"given":"Eva Y.","family":"Andrei","sequence":"additional","affiliation":[{"name":"Department of Physics and Astronomy, Rutgers, The State University of New Jersey , Piscataway, New Jersey 08854, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2024,7,3]]},"reference":[{"key":"2024070313072646000_c1","volume-title":"Introduction to Scanning Tunneling Microscopy","year":"2007"},{"key":"2024070313072646000_c2","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1103\/revmodphys.79.353","article-title":"Scanning tunneling spectroscopy of high-temperature superconductors","volume":"79","year":"2007","journal-title":"Rev. Mod. Phys."},{"key":"2024070313072646000_c3","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1103\/revmodphys.81.1495","article-title":"Spin mapping at the nanoscale and atomic scale","volume":"81","year":"2009","journal-title":"Rev. Mod. Phys."},{"key":"2024070313072646000_c4","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1103\/revmodphys.75.949","article-title":"Advances in atomic force microscopy","volume":"75","year":"2003","journal-title":"Rev. Mod. Phys."},{"key":"2024070313072646000_c5","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1146\/annurev.physchem.54.011002.103852","article-title":"STM control of chemical reactions: Single-molecule synthesis","volume":"54","year":"2003","journal-title":"Annu. Rev. Phys. Chem."},{"key":"2024070313072646000_c6","doi-asserted-by":"publisher","first-page":"044501","DOI":"10.1088\/0034-4885\/71\/4\/044501","article-title":"Scanning probe microscopy of oxide surfaces: Atomic structure and properties","volume":"71","year":"2008","journal-title":"Rep. Prog. Phys."},{"key":"2024070313072646000_c7","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1146\/annurev.matsci.37.052506.084323","article-title":"Nanoscale electromechanics of ferroelectric and biological systems: A new dimension in scanning probe microscopy","volume":"37","year":"2007","journal-title":"Annu. Rev. Mater. Res."},{"key":"2024070313072646000_c8","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1146\/annurev.anchem.111808.073651","article-title":"Scanning electrochemical microscopy in neuroscience","volume":"3","year":"2010","journal-title":"Annu. Rev. Anal. Chem."},{"key":"2024070313072646000_c9","doi-asserted-by":"publisher","first-page":"126501","DOI":"10.1088\/0034-4885\/73\/12\/126501","article-title":"Fundamental studies of superconductors using scanning magnetic imaging","volume":"73","year":"2010","journal-title":"Rep. Prog. Phys."},{"key":"2024070313072646000_c10","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1146\/annurev.matsci.37.052506.084331","article-title":"AFM and acoustics: Fast, quantitative nanomechanical mapping","volume":"37","year":"2007","journal-title":"Annu. Rev. Mater. Res."},{"key":"2024070313072646000_c11","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1146\/annurev.physchem.56.092503.141236","article-title":"Near-field optical microscopy and spectroscopy with pointed probes","volume":"57","year":"2006","journal-title":"Annu. Rev. Phys. Chem."},{"key":"2024070313072646000_c12","doi-asserted-by":"publisher","first-page":"036501","DOI":"10.1088\/0034-4885\/73\/3\/036501","article-title":"Hybrid strategies in nanolithography","volume":"73","year":"2010","journal-title":"Rep. Prog. Phys."},{"key":"2024070313072646000_c13","doi-asserted-by":"publisher","first-page":"1593","DOI":"10.1103\/revmodphys.82.1593","article-title":"Colloquium: Time-resolved scanning tunneling microscopy","volume":"82","year":"2010","journal-title":"Rev. Mod. Phys."},{"key":"2024070313072646000_c14","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1103\/physrevlett.49.57","article-title":"Surface studies by scanning tunneling microscopy","volume":"49","year":"1982","journal-title":"Phys. Rev. Lett."},{"key":"2024070313072646000_c15","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1063\/1.92999","article-title":"Tunneling through a controllable vacuum gap","volume":"40","year":"1982","journal-title":"Appl. Phys. Lett."},{"key":"2024070313072646000_c16","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1103\/RevModPhys.59.615","article-title":"Scanning tunneling microscopy\u2014From birth to adolescence","volume":"59","year":"1987","journal-title":"Rev. Mod. Phys."},{"key":"2024070313072646000_c17","doi-asserted-by":"publisher","first-page":"2855","DOI":"10.1063\/1.1144628","article-title":"Integrated cryogenic scanning tunneling microscopy and sample preparation system","volume":"65","year":"1994","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c18","doi-asserted-by":"publisher","first-page":"2849","DOI":"10.1063\/1.1144626","article-title":"Low-temperature scanning tunneling microscope for use on artificially fabricated nanostructures","volume":"65","year":"1994","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c19","doi-asserted-by":"publisher","first-page":"3806","DOI":"10.1063\/1.1148031","article-title":"A low-temperature ultrahigh-vacuum scanning tunneling microscope with rotatable magnetic field","volume":"68","year":"1997","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c20","doi-asserted-by":"publisher","first-page":"2691","DOI":"10.1063\/1.1149000","article-title":"Design, operation, and housing of an ultrastable, low temperature, ultrahigh vacuum scanning tunneling microscope","volume":"69","year":"1998","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c21","doi-asserted-by":"publisher","first-page":"3428","DOI":"10.1063\/1.1287046","article-title":"Cryogenic variable temperature ultrahigh vacuum scanning tunneling microscope","volume":"71","year":"2000","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c22","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1063\/1.1149555","article-title":"A variable-temperature scanning tunneling microscope capable of single-molecule vibrational spectroscopy","volume":"70","year":"1999","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c23","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1038\/344524a0","article-title":"Positioning single atoms with a scanning tunnelling microscope","volume":"344","year":"1990","journal-title":"Nature"},{"key":"2024070313072646000_c24","doi-asserted-by":"publisher","first-page":"2433","DOI":"10.1103\/PhysRevLett.54.2433","article-title":"Spatial variations in the superconductivity of Nb3Sn measured by low-temperature tunneling microscopy","volume":"54","year":"1985","journal-title":"Phys. Rev. Lett."},{"key":"2024070313072646000_c25","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1038\/nphys653","article-title":"Observation of Landau levels of Dirac fermions in graphite","volume":"3","year":"2007","journal-title":"Nat. Phys."},{"key":"2024070313072646000_c26","doi-asserted-by":"publisher","first-page":"176804","DOI":"10.1103\/PhysRevLett.102.176804","article-title":"Scanning tunneling spectroscopy of graphene on graphite","volume":"102","year":"2009","journal-title":"Phys. Rev. Lett."},{"key":"2024070313072646000_c27","doi-asserted-by":"publisher","first-page":"041405","DOI":"10.1103\/PhysRevB.83.041405","article-title":"Quantized Landau level spectrum and its density dependence in graphene","volume":"83","year":"2011","journal-title":"Phys. Rev. B"},{"key":"2024070313072646000_c28","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1038\/s41567-019-0759-2","article-title":"Spectromicroscopic measurement of surface and bulk band structure interplay in a disordered topological insulator","volume":"16","year":"2020","journal-title":"Nat. Phys."},{"key":"2024070313072646000_c29","doi-asserted-by":"publisher","first-page":"1222","DOI":"10.1007\/s12274-014-0607-8","article-title":"Restoring pristine Bi2Se3 surfaces with an effective Se decapping process","volume":"8","year":"2015","journal-title":"Nano Res."},{"key":"2024070313072646000_c30","doi-asserted-by":"publisher","first-page":"8245","DOI":"10.1021\/acs.nanolett.5b03770","article-title":"Record surface state mobility and quantum Hall effect in topological insulator thin films via interface engineering","volume":"15","year":"2015","journal-title":"Nano Lett."},{"key":"2024070313072646000_c31","doi-asserted-by":"publisher","first-page":"2960","DOI":"10.1063\/1.1147080","article-title":"A simple low-temperature ultrahigh-vacuum scanning tunneling microscope capable of atomic manipulation","volume":"67","year":"1996","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c32","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1063\/1.1150218","article-title":"A low-temperature ultrahigh vacuum scanning tunneling microscope with a split-coil magnet and a rotary motion stepper motor for high spatial resolution studies of surface magnetism","volume":"71","year":"2000","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c33","doi-asserted-by":"publisher","first-page":"056501","DOI":"10.1088\/0034-4885\/75\/5\/056501","article-title":"Electronic properties of graphene: A perspective from scanning tunneling microscopy and magnetotransport","volume":"75","year":"2012","journal-title":"Rep. Prog. Phys."},{"key":"2024070313072646000_c34","doi-asserted-by":"publisher","first-page":"6132","DOI":"10.1021\/acs.nanolett.1c01655","article-title":"Charge density wave vortex lattice observed in graphene-passivated 1T-TaS2 by ambient scanning tunneling microscopy","volume":"21","year":"2021","journal-title":"Nano Lett."},{"key":"2024070313072646000_c35","doi-asserted-by":"publisher","first-page":"121601","DOI":"10.1063\/5.0059662","article-title":"Observation of a topological defect lattice in the charge density wave of 1T-TaS2","volume":"119","year":"2021","journal-title":"Appl. Phys. Lett."},{"key":"2024070313072646000_c36","doi-asserted-by":"publisher","first-page":"4628","DOI":"10.1021\/nl501659n","article-title":"Mid-Gap states, and gating effects in MoS2","volume":"14","year":"2014","journal-title":"Nano Lett."},{"key":"2024070313072646000_c37","doi-asserted-by":"publisher","first-page":"156804","DOI":"10.1103\/physrevlett.113.156804","article-title":"MoS2: Choice substrate for accessing and tuning the electronic properties of graphene","volume":"113","year":"2014","journal-title":"Phys. Rev. Lett."},{"key":"2024070313072646000_c38","doi-asserted-by":"publisher","first-page":"121101","DOI":"10.1063\/1.3520482","article-title":"Invited review article: A 10 mK scanning probe microscopy facility","volume":"81","year":"2010","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c39","doi-asserted-by":"publisher","first-page":"121301","DOI":"10.1063\/1.4902536","article-title":"Invited Article: Autonomous assembly of atomically perfect nanostructures using a scanning tunneling microscope","volume":"85","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c40","doi-asserted-by":"publisher","first-page":"023703","DOI":"10.1063\/1.5132872","article-title":"A modular ultra-high vacuum millikelvin scanning tunneling microscope","volume":"91","year":"2020","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c41","doi-asserted-by":"publisher","first-page":"071101","DOI":"10.1063\/5.0005320","article-title":"Achieving \u03bceV tunneling resolution in an in-operando scanning tunneling microscopy, atomic force microscopy, and magnetotransport system for quantum materials research","volume":"91","year":"2020","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c42","unstructured":"A. M. Coe , G.Li, and E. Y.Andrei, \u201cModular scanning probe microscope head,\u201d US 11,474,127 B2. Application No.: 17\/313,743 (2021)."},{"key":"2024070313072646000_c43"},{"key":"2024070313072646000_c44"},{"key":"2024070313072646000_c45"},{"key":"2024070313072646000_c46"},{"key":"2024070313072646000_c47"},{"key":"2024070313072646000_c48"},{"key":"2024070313072646000_c49"},{"key":"2024070313072646000_c50"},{"key":"2024070313072646000_c51"},{"key":"2024070313072646000_c52","unstructured":"G. Li and E. Y.Andrei, \u201cLow profile transfer mechanism for controlled environments,\u201d Patent WO 2019\/209592 A2. Application No.: PCT\/US2019\/027929 (2019)."},{"key":"2024070313072646000_c53","doi-asserted-by":"publisher","first-page":"073701","DOI":"10.1063\/1.3605664","article-title":"Self-navigation of a scanning tunneling microscope tip toward a micron-sized graphene sample","volume":"82","year":"2011","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c54","unstructured":"T. Berghaus and P.Klaede, \u201cAdjusting device for microscopic movements,\u201d Patent US 9,237,238\u00a0A. Application No.: 07\/732,224 (1993)."},{"key":"2024070313072646000_c55","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/0039-6028(87)90151-8","article-title":"An easily operable scanning tunneling microscope","volume":"181","year":"1987","journal-title":"Surf. Sci."},{"key":"2024070313072646000_c56","doi-asserted-by":"publisher","first-page":"1200","DOI":"10.1063\/1.1140287","article-title":"Coarse tip distance adjustment and positioner for a scanning tunneling microscope","volume":"60","year":"1989","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c57","doi-asserted-by":"publisher","first-page":"2010","DOI":"10.1063\/1.1139508","article-title":"Scanning tunneling microscope","volume":"58","year":"1987","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c58","doi-asserted-by":"publisher","first-page":"984","DOI":"10.1116\/1.585441","article-title":"A low-temperature atomic force\/scanning tunneling microscope for ultrahigh vacuum","volume":"9","year":"1991","journal-title":"J.\u00a0Vac. Sci. Technol., B: Microelectron. Nanometer Struct.\u2013Process., Meas., Phenom."},{"key":"2024070313072646000_c59","doi-asserted-by":"publisher","first-page":"1459","DOI":"10.1063\/1.1149605","article-title":"3He refrigerator based very low temperature scanning tunneling microscope","volume":"70","year":"1999","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c60","unstructured":"S. H. Pan , \u201cPiezoelectric motor,\u201d Patent WO 93\/19494. Application No.: PCT\/GB93\/000539 (1993)."},{"key":"2024070313072646000_c61","doi-asserted-by":"publisher","first-page":"3625","DOI":"10.1063\/1.1149970","article-title":"A low temperature ultrahigh vacuum scanning force microscope","volume":"70","year":"1999","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c62","doi-asserted-by":"publisher","first-page":"1120","DOI":"10.3762\/bjnano.13.95","article-title":"A cantilever-based, ultrahigh-vacuum, low-temperature scanning probe instrument for multidimensional scanning force microscopy","volume":"13","year":"2022","journal-title":"Beilstein J. Nanotechnol."},{"key":"2024070313072646000_c63"},{"key":"2024070313072646000_c64"},{"key":"2024070313072646000_c65","author":"INSANCO Inc."},{"key":"2024070313072646000_c66"},{"key":"2024070313072646000_c67"},{"key":"2024070313072646000_c68"},{"key":"2024070313072646000_c69"},{"key":"2024070313072646000_c70"},{"key":"2024070313072646000_c71"},{"key":"2024070313072646000_c72"},{"key":"2024070313072646000_c73","doi-asserted-by":"publisher","first-page":"083701","DOI":"10.1063\/5.0013921","article-title":"Combined atomic force microscope and scanning tunneling microscope with high optical access achieving atomic resolution in ambient conditions","volume":"91","year":"2020","journal-title":"Rev. Sci. Instrum."},{"key":"2024070313072646000_c74","unstructured":"A. M. Coe , G.Li, and E. Y.Andrei, \u201cDamping base for modular scanning probe microscope head,\u201d Patent WO 2021\/226354 A1. Application No.: PCT\/US2021\/031120 (2021)."},{"key":"2024070313072646000_c75","doi-asserted-by":"crossref","unstructured":"A. M. Coe , G.Li, and E. Y.Andrei, \u201cCryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform,\u201d arxiv:2404.05002 (2024).","DOI":"10.1063\/5.0212244"}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0204940\/20028093\/073703_1_5.0204940.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0204940\/20028093\/073703_1_5.0204940.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,23]],"date-time":"2024-11-23T05:50:40Z","timestamp":1732341040000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/95\/7\/073703\/3300865\/Quick-connect-scanning-tunneling-microscope-head"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,1]]},"references-count":75,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2024,7,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0204940","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,7,1]]},"published":{"date-parts":[[2024,7,1]]},"article-number":"073703"}}