{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,6]],"date-time":"2026-09-06T04:29:10Z","timestamp":1788668950372,"version":"build-2803163510"},"reference-count":16,"publisher":"AIP Publishing","issue":"2","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,6,1]]},"abstract":"<jats:p>The realm of implantable bioelectronics represents a frontier in medical science, merging technology, biology, and medicine to innovate treatments that enhance, restore, or monitor physiological functions. This field has yielded devices like cochlear implants, cardiac pacemakers, deep brain stimulators, and vagus nerve stimulators, each designed to address a specific health condition, ranging from sensorineural hearing loss to chronic pain, neurological disorders, and heart rhythm irregularities. Such devices underscore the potential of bioelectronics to significantly improve patient outcomes and quality of life. Recent technological breakthroughs in materials science, nanotechnology, and microfabrication have enabled the development of more sophisticated, smaller, and biocompatible bioelectronic devices. However, the field also encounters challenges, particularly in extending the capabilities of devices such as retinal prostheses, which aim to restore vision but currently offer limited visual acuity. Research in implantable bioelectronics is highly timely, driven by an aging global population with a growing prevalence of chronic diseases that could benefit from these technologies. The convergence of societal health needs, advancing technological capabilities, and a supportive ecosystem for innovation marks this era as pivotal for bioelectronic research.<\/jats:p>","DOI":"10.1063\/5.0209537","type":"journal-article","created":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T12:36:46Z","timestamp":1716899806000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":6,"title":["Guest Editorial: Implantable bioelectronics"],"prefix":"10.1063","volume":"8","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4213-9575","authenticated-orcid":false,"given":"Yael","family":"Hanein","sequence":"first","affiliation":[{"name":"School of Electrical Engineering, Tel Aviv University 1 , Tel Aviv, Israel"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7317-0997","authenticated-orcid":false,"given":"Josef","family":"Goding","sequence":"additional","affiliation":[{"name":"Department of Bioengineering, Imperial College 2 , London, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2024,5,28]]},"reference":[{"key":"2024052812361051300_c1","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1001\/jamaneurol.2022.4847","article-title":"Assessment of safety of a fully implanted endovascular brain-computer interface for severe paralysis in 4 patients: The Stentrode With Thought-Controlled Digital Switch (SWITCH) Study","volume":"80","year":"2023","journal-title":"JAMA Neurol."},{"key":"2024052812361051300_c2","doi-asserted-by":"publisher","first-page":"e16194","DOI":"10.2196\/16194","article-title":"An integrated brain-machine interface platform with thousands of channels","volume":"21","year":"2019","journal-title":"J. Med. Internet Res."},{"key":"2024052812361051300_c3","first-page":"1","article-title":"Flexible circuit technologies for biomedical applications","volume-title":"Advances in Micro\/Nano Electromechanical Systems and Fabrication Technologies","year":"2013"},{"key":"2024052812361051300_c4","doi-asserted-by":"publisher","first-page":"eabn4732","DOI":"10.1126\/science.abn4732","article-title":"Miniature battery-free bioelectronics","volume":"382","year":"2023","journal-title":"Science"},{"key":"2024052812361051300_c5","doi-asserted-by":"publisher","first-page":"2105281","DOI":"10.1002\/smll.202105281","article-title":"Emerging bioelectronic strategies for cardiovascular tissue engineering and implantation","volume":"18","year":"2022","journal-title":"Small"},{"key":"2024052812361051300_c6","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1146\/annurev-chembioeng-101420-024336","article-title":"Wearable and implantable soft bioelectronics: Device designs and material strategies","volume":"12","year":"2021","journal-title":"Annu. Rev. Chem. Biomol. Eng."},{"key":"2024052812361051300_c7","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1038\/ncomms1164","article-title":"A hybrid bioorganic interface for neuronal photoactivation","volume":"2","year":"2011","journal-title":"Nat. Commun."},{"key":"2024052812361051300_c8","doi-asserted-by":"publisher","first-page":"046117","DOI":"10.1063\/5.0153094","article-title":"PEDOT:PSS-coated platinum electrodes for neural stimulation","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c9","doi-asserted-by":"publisher","first-page":"046109","DOI":"10.1063\/5.0163264","article-title":"Finite element analysis of electric field distribution during direct current stimulation of the spinal cord: Implications for device design","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c10","doi-asserted-by":"publisher","first-page":"031503","DOI":"10.1063\/5.0153753","article-title":"Emerging trends in the development of flexible optrode arrays for electrophysiology","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c11","doi-asserted-by":"publisher","first-page":"036109","DOI":"10.1063\/5.0152509","article-title":"A low-profile electromechanical packaging system for soft-to-flexible bioelectronic interfaces","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c12","doi-asserted-by":"publisher","first-page":"026102","DOI":"10.1063\/5.0138861","article-title":"Aqueous electrolyte-gated solution-processed metal oxide transistors for direct cellular interfaces","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c13","doi-asserted-by":"publisher","first-page":"046105","DOI":"10.1063\/5.0156463","article-title":"Investigations on artificially extending the spectral range of natural vision","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c14","doi-asserted-by":"publisher","first-page":"031505","DOI":"10.1063\/5.0152669","article-title":"Generation of direct current electrical fields as regenerative therapy for spinal cord injury: A review","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c15","doi-asserted-by":"publisher","first-page":"046101","DOI":"10.1063\/5.0156484","article-title":"Decoding bladder state from pudendal intraneural signals in pigs","volume":"7","year":"2023","journal-title":"APL Bioeng."},{"key":"2024052812361051300_c16","doi-asserted-by":"publisher","first-page":"031506","DOI":"10.1063\/5.0152290","article-title":"Current state of the art and future directions for implantable sensors in medical technology: Clinical needs and engineering challenges","volume":"7","year":"2023","journal-title":"APL Bioeng."}],"container-title":["APL Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0209537\/19967620\/020401_1_5.0209537.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0209537\/19967620\/020401_1_5.0209537.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,28]],"date-time":"2024-05-28T12:36:49Z","timestamp":1716899809000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/apb\/article\/8\/2\/020401\/3295179\/Guest-Editorial-Implantable-bioelectronics"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,28]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,6,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0209537","relation":{},"ISSN":["2473-2877"],"issn-type":[{"value":"2473-2877","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2024,6,1]]},"published":{"date-parts":[[2024,5,28]]},"article-number":"020401"}}