{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T03:31:49Z","timestamp":1778643109320,"version":"3.51.4"},"reference-count":39,"publisher":"AIP Publishing","issue":"3","funder":[{"DOI":"10.13039\/501100001843","name":"Science and Engineering Research Board","doi-asserted-by":"publisher","award":["CRG\/2021\/000398"],"award-info":[{"award-number":["CRG\/2021\/000398"]}],"id":[{"id":"10.13039\/501100001843","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,3,1]]},"abstract":"<jats:p>This paper presents a method for measuring the thermal conductivity of activated carbon adsorbents at liquid nitrogen (LN2) temperature for LN2-based cryo-adsorption vacuum pumps. This method is simple, versatile, and adaptable to various sample geometries of material under evaluation, including powders, spheres, granules, and pellets. This method can also be applied to assess similar materials with thermal conductivity in the range of 0.1\u20131.5 W\/(m K). The thermal conductivity was evaluated by establishing a temperature gradient across the LN2-cooled sample using controlled heat inputs. The measurement accuracy was verified using glassy glycerol whose thermal conductivities at LN2 temperature had already been studied and reported in the literature. The thermal conductivities of activated carbon measured ranged from 0.14 to 0.25 W\/(m K) across different sample types and conditions, including forms, packing density, and filler compositions. With an error margin established at 5%, the technique proves both effective and reliable for thermal conductivity measurements at LN2 temperature, offering promising applications in cryogenic engineering, insulation material development, and thermal management systems.<\/jats:p>","DOI":"10.1063\/5.0242242","type":"journal-article","created":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T12:40:16Z","timestamp":1742992816000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":2,"title":["Assessment of thermal conductivity in activated carbon adsorbents for liquid nitrogen-based cryo-adsorption vacuum pump applications"],"prefix":"10.1063","volume":"96","author":[{"ORCID":"https:\/\/orcid.org\/0009-0009-6329-6332","authenticated-orcid":false,"given":"Abdul","family":"Nazer K H","sequence":"first","affiliation":[{"name":"Cochin University of Science and Technology , Ernakulam, Kerala 682022,","place":["India"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-9772-9221","authenticated-orcid":false,"given":"Namitha","family":"Venugopal","sequence":"additional","affiliation":[{"name":"Cochin University of Science and Technology , Ernakulam, Kerala 682022,","place":["India"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0003-0431-4365","authenticated-orcid":false,"given":"Hrithik Krishna","family":"Raj","sequence":"additional","affiliation":[{"name":"Cochin University of Science and Technology , Ernakulam, Kerala 682022,","place":["India"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1138-1810","authenticated-orcid":false,"given":"Chinnu","family":"V K","sequence":"additional","affiliation":[{"name":"Cochin University of Science and Technology , Ernakulam, Kerala 682022,","place":["India"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2064-1660","authenticated-orcid":false,"given":"Pankaj","family":"Sagar","sequence":"additional","affiliation":[{"name":"Cochin University of Science and Technology , Ernakulam, Kerala 682022,","place":["India"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"317","published-online":{"date-parts":[[2025,3,26]]},"reference":[{"key":"2025032608355532100_c1","doi-asserted-by":"publisher","first-page":"110986","DOI":"10.1016\/j.vacuum.2022.110986","article-title":"Design and development of a liquid nitrogen cooled test cryopump for application in Steady-state Superconducting Tokamak-1","volume":"200","year":"2022","journal-title":"Vacuum"},{"key":"2025032608355532100_c2","doi-asserted-by":"crossref","first-page":"48","DOI":"10.1016\/B978-1-4831-9852-1.50017-7","article-title":"An ultra-high-vacuum chamber for space simulation","volume-title":"Vacuum Technology Transactions","year":"2013"},{"key":"2025032608355532100_c3","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.vacuum.2008.05.010","article-title":"The vacuum systems of ITER","volume":"83","year":"2008","journal-title":"Vacuum"},{"key":"2025032608355532100_c4","doi-asserted-by":"publisher","first-page":"076901","DOI":"10.1088\/0034-4885\/72\/7\/076901","article-title":"LIGO: The laser interferometer gravitational-wave observatory","volume":"72","year":"2009","journal-title":"Rep. Prog. Phys."},{"key":"2025032608355532100_c5","doi-asserted-by":"publisher","first-page":"16107","DOI":"10.1109\/jsen.2023.3281751","article-title":"Tunable spatial resolution of a scanning probe microscopy (SPM) by an efficient cryosorption pump","volume":"23","year":"2023","journal-title":"IEEE Sens. J."},{"key":"2025032608355532100_c6","doi-asserted-by":"publisher","first-page":"304","DOI":"10.3788\/ope.20111902.0304","article-title":"Efficient nitrogen diluted discharge-driven continuous wave HF\/DF chemical lasers","volume":"19","year":"2011","journal-title":"Opt. Precis. Eng."},{"key":"2025032608355532100_c7","doi-asserted-by":"publisher","first-page":"86771N","DOI":"10.1117\/12.2010490","article-title":"Development of efficient nitrogen diluted discharge-driven HF CW chemical laser","volume":"8677","year":"2013","journal-title":"Proc. SPIE"},{"key":"2025032608355532100_c8","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1117\/12.384268","article-title":"Chemical oxygen-iodine laser with cryosorption vacuum pump","volume":"3931","year":"2000","journal-title":"Proc. SPIE"},{"key":"2025032608355532100_c9","doi-asserted-by":"publisher","first-page":"832","DOI":"10.1007\/s10556-016-0130-8","article-title":"The economics of cryosorption pumping. the practice of using a cryosorption pump in an industrial pumping system","volume":"51","year":"2016","journal-title":"Chem. Pet. Eng."},{"key":"2025032608355532100_c10","first-page":"424","article-title":"James Dewar\u2014more than a flask","volume":"10","year":"2003","journal-title":"Indian J. Chem. Technol."},{"key":"2025032608355532100_c11","article-title":"Development and application of cryosorption pumping of hydrogen at 20\u00a0K by molecular sieve adsorbent panels","year":"1965"},{"key":"2025032608355532100_c12","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1116\/1.569871","article-title":"Helium pumping at 4.2\u00a0K by molecular sieve 5A","volume":"16","year":"1979","journal-title":"J.\u00a0Vac. Sci. Technol."},{"key":"2025032608355532100_c13","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1116\/1.572009","article-title":"Vacuum applications for the tritium systems test assembly","volume":"1","year":"1983","journal-title":"J.\u00a0Vac. Sci. Technol., A"},{"key":"2025032608355532100_c14","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1016\/0167-899x(87)90002-4","article-title":"Cryopumping for fusion reactors","volume":"4","year":"1987","journal-title":"Nucl. Eng. Des.\/Fusion"},{"key":"2025032608355532100_c15","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/0920-3796(89)90056-2","article-title":"Development and application of charcoal sorbents for cryopumping fusion devices","volume":"10","year":"1989","journal-title":"Fusion Eng. Des."},{"key":"2025032608355532100_c16","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/s0011-2275(05)80085-2","article-title":"Cryosorption pumping of H2 and He with metals and metal oxides at 4.3 K","volume":"34","year":"1994","journal-title":"Cryogenics"},{"key":"2025032608355532100_c17","article-title":"Cryosorbent characterization of activated charcoal in the COOLSORP Facility","year":"2002"},{"key":"2025032608355532100_c18","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1007\/978-1-4757-9047-4_166","article-title":"Pumping performance of cryopanels coated with activated carbon","volume-title":"Advances in Cryogenic Engineering","year":"1998"},{"key":"2025032608355532100_c19","doi-asserted-by":"publisher","first-page":"012098","DOI":"10.1088\/1757-899x\/171\/1\/012098","article-title":"Measurement of thermal conductivity of materials down to 4.5\u00a0K for development of cryosorption pumps","volume":"171","year":"2017","journal-title":"IOP Conf. Ser.: Mater. Sci. Eng."},{"key":"2025032608355532100_c20","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.crci.2014.07.011","article-title":"Copper supported on porous activated carbon obtained by wetness impregnation: Effect of preparation conditions on the ozonation catalyst\u2019s characteristics","volume":"18","year":"2014","journal-title":"C. R. Chim."},{"key":"2025032608355532100_c21","doi-asserted-by":"publisher","first-page":"107163","DOI":"10.1016\/j.compositesb.2019.107163","article-title":"Performance improvement of cryosorption pump by enhancing thermal conductivity of epoxy-aluminum composite","volume":"176","year":"2019","journal-title":"Composites, Part B"},{"key":"2025032608355532100_c22","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1016\/s1004-9541(13)60525-x","article-title":"Comparison on thermal conductivity and permeability of granular and consolidated activated carbon for refrigeration","volume":"21","year":"2013","journal-title":"Chin. J. Chem. Eng."},{"key":"2025032608355532100_c23","doi-asserted-by":"publisher","first-page":"043501","DOI":"10.1115\/1.4055341","article-title":"Thermal conductivity of some ceramic materials at cryogenic temperatures","volume":"145","year":"2023","journal-title":"ASME J. Heat Mass Transfer"},{"key":"2025032608355532100_c24","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1016\/j.cryogenics.2006.08.001","article-title":"The thermal conductivity of cryogenic insulation materials and its temperature dependence","volume":"46","year":"2006","journal-title":"Cryogenics"},{"key":"2025032608355532100_c25","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/978-1-4613-9850-9_27","article-title":"Thermal conductivity of microsphere cryogenic insulation","volume-title":"Advances in Cryogenic Engineering","year":"1977"},{"key":"2025032608355532100_c26","doi-asserted-by":"publisher","first-page":"3193","DOI":"10.1063\/1.1147583","article-title":"Test of an apparatus for thermal conductivity measurements of superconducting coil blocks and materials at cryogenic temperatures","volume":"67","year":"1996","journal-title":"Rev. Sci. Instrum."},{"key":"2025032608355532100_c27","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s10786-005-0074-2","article-title":"A setup for studying the low-temperature thermal conductivity of powder samples","volume":"48","year":"2005","journal-title":"Instrum. Exp. Tech."},{"key":"2025032608355532100_c28","unstructured":"M.\n            Barrios\n          , \u201cMeasuring thermal conductivity of powder insulation at cryogenic temperatures,\u201d M.S. thesis, Florida State University, 2006, http:\/\/purl.flvc.org\/fsu\/fd\/FSU_migr_etd-1112."},{"key":"2025032608355532100_c29","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/s0921-4526(99)01840-2","article-title":"Pulse-tube refrigerators: Principle, recent developments, and prospects","volume":"280","year":"2000","journal-title":"Physica B"},{"key":"2025032608355532100_c30","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.cryogenics.2017.11.004","article-title":"Cylindrical cryogenic calorimeter testing of six types of multilayer insulation systems","volume":"89","year":"2018","journal-title":"Cryogenics"},{"key":"2025032608355532100_c31","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1063\/1.4707055","article-title":"Thermal property of insulation material for HTS power cable","volume":"1434","year":"2012","journal-title":"AIP Conf. Proc."},{"key":"2025032608355532100_c32","volume-title":"Fundamentals of Heat and Mass Transfer","year":"1985"},{"key":"2025032608355532100_c33","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.cryogenics.2004.11.006","article-title":"Thermal conductivity of Torlon between 4.2 and 300 K","volume":"45","year":"2005","journal-title":"Cryogenics"},{"key":"2025032608355532100_c34","unstructured":"Cryogenics Material Properties\u2014trc.nist.gov, https:\/\/trc.nist.gov\/cryogenics\/materials\/materialproperties.htm (accessed 18 July 2024)."},{"key":"2025032608355532100_c35","doi-asserted-by":"publisher","first-page":"012203","DOI":"10.1103\/physrevb.65.012203","article-title":"Low-temperature specific heat and thermal conductivity of glycerol","volume":"65","year":"2001","journal-title":"Phys. Rev. B"},{"key":"2025032608355532100_c36","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1016\/j.cryogenics.2009.08.001","article-title":"Thermal conductivity of Kevlar 49 between 7 and 290 K","volume":"49","year":"2009","journal-title":"Cryogenics"},{"key":"2025032608355532100_c37","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1016\/j.cryogenics.2008.03.018","article-title":"Measurement of thermal conductivity of the supports of CUORE cryostat","volume":"48","year":"2008","journal-title":"Cryogenics"},{"key":"2025032608355532100_c38","unstructured":"Product Documentation - NI\u2014ni.com, https:\/\/www.ni.com\/docs\/en-US\/bundle\/ni-9234-specs\/page\/specs.html (accessed 18 December 2024)."},{"key":"2025032608355532100_c39","unstructured":"sjelectronics.co.uk, https:\/\/www.sjelectronics.co.uk\/pub\/media\/pdf\/keithley-6220-6221-datasheet.pdf (accessed 18 December 2024)."}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0242242\/20456685\/035119_1_5.0242242.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0242242\/20456685\/035119_1_5.0242242.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,26]],"date-time":"2025-03-26T12:40:48Z","timestamp":1742992848000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/96\/3\/035119\/3340812\/Assessment-of-thermal-conductivity-in-activated"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,1]]},"references-count":39,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025,3,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0242242","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,3]]},"published":{"date-parts":[[2025,3,1]]},"article-number":"035119"}}