{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,12]],"date-time":"2026-02-12T12:11:26Z","timestamp":1770898286857,"version":"3.50.1"},"reference-count":41,"publisher":"AIP Publishing","issue":"2","license":[{"start":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T00:00:00Z","timestamp":1749600000000},"content-version":"vor","delay-in-days":10,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100016175","name":"Chulabhorn Royal Academy","doi-asserted-by":"publisher","award":["FRB660044\/0240 Project code 180847"],"award-info":[{"award-number":["FRB660044\/0240 Project code 180847"]}],"id":[{"id":"10.13039\/100016175","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,6,1]]},"abstract":"<jats:p>Fractures of the distal radius often require surgical intervention, with plate fixation being a standard stabilization method. Screw loosening and pull-out propose significant complications, necessitating comprehensive understanding of fixation stability factors. This study introduces a novel approach by the combination of finite element analysis (FEA) and experimental investigations on Thiel cadavers to evaluate screw pull-out behavior from plate fixation in en bloc distal radius resection with ulnar reconstruction. In comparison with previous investigations that used computational modeling or fresh-frozen cadaveric specimens, in the present research, FEA predictions specifically experimentally confirm the usage of Thiel cadavers, which better preserve soft tissue elasticity and hydration, thus more closely reflect in vivo conditions. Experimental set-up consisted of bending tests on cadavers and screw pull-out tests in Thiel-cadaveric radius specimens mimicking physiological conditions that induce the effects of screw pull-out. Finite element analysis and simulation were conducted using realistic clinical cases. Biomechanical test results indicated locking-plate deformation and screw loosening, particularly at locations closest to the ulnar bone gap. Torque measurements established various degrees of screw loosening, with the screws closest to the bone gap indicating maximum loosening. FEA demonstrated critical distributions of stresses in screws and locking plates, with good correlations to experimental findings. Screw pull-out force analysis showed vulnerability to loosening, particularly in the area of bone gaps, with findings consistent between biomechanical testing and FEA. This study offers valuable information on the surgical implications and biomechanical considerations of plate fixation for en bloc distal radius resection with ulnar reconstruction.<\/jats:p>","DOI":"10.1063\/5.0248553","type":"journal-article","created":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T12:37:44Z","timestamp":1749645464000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":2,"title":["Evaluation of screw pull-out from plate fixation of en bloc distal radius resection with ulnar reconstruction: Finite element analysis and comparison with experiments on Thiel cadavers"],"prefix":"10.1063","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5223-4867","authenticated-orcid":false,"given":"Wares","family":"Chancharoen","sequence":"first","affiliation":[{"name":"Laboratory of Artificial Intelligence and Innovation in Medicine (AIIM), Princess Srisavangavadhana Faculty of Medicine, Chulabhorn Royal Academy 1 , 906 Kamphaeng Phet 6 Road, Talat Bang Khen, Lak Si, Bangkok 10210,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7120-8568","authenticated-orcid":false,"given":"Theingi","family":"Nwe","sequence":"additional","affiliation":[{"name":"Laboratory of Artificial Intelligence and Innovation in Medicine (AIIM), Princess Srisavangavadhana Faculty of Medicine, Chulabhorn Royal Academy 1 , 906 Kamphaeng Phet 6 Road, Talat Bang Khen, Lak Si, Bangkok 10210,","place":["Thailand"]},{"name":"Department of Mechanical Engineering, Naypyitaw State Polytechnic University, Thirimandhain Junction, Pubbathiri Township 2 , Naypyitaw 15014,","place":["Myanmar"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9471-0836","authenticated-orcid":false,"given":"Saran","family":"Seehanam","sequence":"additional","affiliation":[{"name":"Laboratory of Artificial Intelligence and Innovation in Medicine (AIIM), Princess Srisavangavadhana Faculty of Medicine, Chulabhorn Royal Academy 1 , 906 Kamphaeng Phet 6 Road, Talat Bang Khen, Lak Si, Bangkok 10210,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-0193-6600","authenticated-orcid":false,"given":"Napawan","family":"Taradolpisut","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Faculty of Science, Mahidol University 3 , 272 Rama VI Road, Ratchathewi, Bangkok 10400,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-5568-6539","authenticated-orcid":false,"given":"Thewarid","family":"Berkband","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Faculty of Medicine, Khon Kaen University, 123 Moo 16, Mittraphap Road, T. Naimuang A. Muang 4 , Khon Kaen 40002,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2482-8203","authenticated-orcid":false,"given":"Thanapon","family":"Chobpenthai","sequence":"additional","affiliation":[{"name":"Laboratory of Artificial Intelligence and Innovation in Medicine (AIIM), Princess Srisavangavadhana Faculty of Medicine, Chulabhorn Royal Academy 1 , 906 Kamphaeng Phet 6 Road, Talat Bang Khen, Lak Si, Bangkok 10210,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3169-2789","authenticated-orcid":false,"given":"Chavin","family":"Jongwannasiri","sequence":"additional","affiliation":[{"name":"Laboratory of Artificial Intelligence and Innovation in Medicine (AIIM), Princess Srisavangavadhana Faculty of Medicine, Chulabhorn Royal Academy 1 , 906 Kamphaeng Phet 6 Road, Talat Bang Khen, Lak Si, Bangkok 10210,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6030-8160","authenticated-orcid":false,"given":"Laphatrada","family":"Yurasakpong","sequence":"additional","affiliation":[{"name":"Department of Anatomy, Faculty of Science, Mahidol University 3 , 272 Rama VI Road, Ratchathewi, Bangkok 10400,","place":["Thailand"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"317","published-online":{"date-parts":[[2025,6,11]]},"reference":[{"issue":"6","key":"2025061108373963900_c1","doi-asserted-by":"publisher","first-page":"608","DOI":"10.3928\/01477447-20080601-05","article-title":"Modified ulnar translocation technique for the reconstruction of giant cell tumor of the distal radius","volume":"31","year":"2008","journal-title":"Orthopedics"},{"issue":"10","key":"2025061108373963900_c2","doi-asserted-by":"publisher","first-page":"2886","DOI":"10.1007\/s11999-012-2464-7","article-title":"Which treatment is the best for giant cell tumors of the distal radius? A meta-analysis","volume":"470","year":"2012","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"4","key":"2025061108373963900_c3","doi-asserted-by":"publisher","first-page":"1442","DOI":"10.4067\/S0717-95022016000400044","article-title":"Walter Thiel's embalming method: Review of solutions and applications in different fields of biomedical research","volume":"34","year":"2016","journal-title":"Int. J. Morphol."},{"issue":"5","key":"2025061108373963900_c4","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1002\/ca.22222","article-title":"From formalin to Thiel embalming: What changes? One anatomy department's experiences","volume":"26","year":"2013","journal-title":"Clin. Anat."},{"issue":"5","key":"2025061108373963900_c5","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1007\/s00268-016-3868-4","article-title":"A multispecialty evaluation of Thiel cadavers for surgical training","volume":"41","year":"2017","journal-title":"World J. Surg."},{"issue":"2","key":"2025061108373963900_c6","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1007\/s12178-019-09544-8","article-title":"Complications in the management of distal radius fractures: How do we avoid them?","volume":"12","year":"2019","journal-title":"Curr. Rev. Musculoskeletal Med."},{"issue":"5","key":"2025061108373963900_c7","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","article-title":"Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate","volume":"21","year":"2007","journal-title":"J. Orthop. Trauma"},{"issue":"10","key":"2025061108373963900_c8","doi-asserted-by":"publisher","first-page":"2489","DOI":"10.1111\/os.13468","article-title":"Open reduction and internal fixation by volar locking plates and the \u2018poking reduction\u2019 technique in distal radius fractures with displaced dorsal ulnar fragments: A retrospective study","volume":"14","year":"2022","journal-title":"Orthop. Surg."},{"issue":"3","key":"2025061108373963900_c9","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1177\/230949901302100314","article-title":"Mechanical failure of the distal radius volar locking plate","volume":"21","year":"2013","journal-title":"J. Orthop. Surg."},{"issue":"12","key":"2025061108373963900_c10","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1016\/j.jhsa.2011.08.039","article-title":"A biomechanical comparison of volar locked plating of intra-articular distal radius fractures: Use of 4 versus 7 screws for distal fixation","volume":"36","year":"2011","journal-title":"J. Hand Surg."},{"issue":"3","key":"2025061108373963900_c11","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1142\/S0218810417720248","article-title":"Locking screw migration to the palm four years following surgical implantation of distal radius locking plate","volume":"22","year":"2017","journal-title":"J. Hand Surg."},{"issue":"3","key":"2025061108373963900_c12","doi-asserted-by":"publisher","first-page":"586","DOI":"10.3390\/app9030586","article-title":"Experimental evaluation of screw pullout force and adjacent bone damage according to pedicle screw design parameters in normal and osteoporotic bones","volume":"9","year":"2019","journal-title":"Appl. Sci."},{"issue":"21","key":"2025061108373963900_c13","doi-asserted-by":"publisher","first-page":"9901","DOI":"10.3390\/app11219901","article-title":"Biomechanical comparison of fixation stability among various pedicle screw geometries: Effects of screw outer\/inner projection shape and thread profile","volume":"11","year":"2021","journal-title":"Appl. Sci."},{"issue":"15","key":"2025061108373963900_c14","doi-asserted-by":"publisher","first-page":"4116","DOI":"10.1016\/j.jbiomech.2015.10.012","article-title":"The influence of bone density and anisotropy in finite element models of distal radius fracture osteosynthesis: Evaluations and comparison to experiments","volume":"48","year":"2015","journal-title":"J. Biomech."},{"issue":"8","key":"2025061108373963900_c15","doi-asserted-by":"publisher","first-page":"103340","DOI":"10.1016\/j.otsr.2022.103340","article-title":"Biomechanical analysis of locking plates for fixation of metacarpal shaft fractures: A finite element analysis","volume":"108","year":"2022","journal-title":"Orthop. Traumatol.: Surg. Res."},{"issue":"1","key":"2025061108373963900_c16","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1186\/s12891-022-05751-6","article-title":"Fixation stability comparison of bone screws based on thread design: Buttress thread, triangle thread, and square thread","volume":"23","year":"2022","journal-title":"BMC Musculoskeletal Disord."},{"issue":"3","key":"2025061108373963900_c17","doi-asserted-by":"publisher","first-page":"E226","DOI":"10.1097\/BSD.0000000000000151","article-title":"Finite element analysis-based pre-operative application for biomechanical evaluation of a locking plate used in reconstruction after en bloc resection of a stage 3 giant cell tumor of the distal radius","volume":"30","year":"2017","journal-title":"Clin. Spine Surg."},{"key":"2025061108373963900_c18","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1007\/978-3-031-18130-6","article-title":"Finite element analysis to determine pull-out strength of fixation around large defect site in femur reconstruction surgery","volume-title":"Materials Design and Applications IV","author":"Da Silva","year":"2023"},{"issue":"5","key":"2025061108373963900_c19","doi-asserted-by":"publisher","first-page":"543","DOI":"10.3109\/17453674.2012.727079","article-title":"Embalmed and fresh frozen human bones in orthopedic cadaveric studies: Which bone is authentic and feasible?: A mechanical study","volume":"83","year":"2012","journal-title":"Acta Orthop."},{"key":"2025061108373963900_c20","doi-asserted-by":"publisher","first-page":"110018","DOI":"10.1016\/j.jbiomech.2020.110018","article-title":"Evaluating the mechanical response of novel synthetic femurs for representing osteoporotic bone","volume":"111","year":"2020","journal-title":"J. Biomech."},{"issue":"4","key":"2025061108373963900_c21","doi-asserted-by":"publisher","first-page":"990","DOI":"10.1097\/TA.0b013e31802bf051","article-title":"The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone","volume":"64","year":"2008","journal-title":"J. Trauma: Inj., Infect. Crit. Care"},{"key":"2025061108373963900_c22","unstructured":"D.\n            Benoit\n          , F. L.Nav\u00e9aux, A.Posch, and J.Clin, see https:\/\/numalogics.com\/wp-content\/uploads\/2023\/05\/White_Paper_Orthopedic_Screw_Pullout_Prediction.pdf for \u201cOrthopedic screw pullout prediction: Validation of a virtual mechanical test for the prediction of screw pullout forces in sawbones polyurethane foam in accordance to ASTM F543 standard orthopedic screw pullout prediction\u201d (2023)."},{"issue":"2","key":"2025061108373963900_c23","first-page":"157","article-title":"Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine","volume":"67","year":"2001","journal-title":"Acta Orthop. Belg."},{"issue":"3","key":"2025061108373963900_c24","doi-asserted-by":"publisher","first-page":"503","DOI":"10.1243\/09544119JEIM675","article-title":"The effect of the screw pull-out rate on cortical screw purchase in unreamed and reamed synthetic long bones","volume":"224","year":"2010","journal-title":"Proc. Inst. Mech. Eng., Part H"},{"key":"2025061108373963900_c25","doi-asserted-by":"publisher","DOI":"10.1080\/10255842.2024.2358362","article-title":"Performance parametric formulation of carbon fiber-reinforced composite locking bone implant plates based on finite-element analysis","year":"2024","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"issue":"5","key":"2025061108373963900_c26","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1177\/17531934211068622","article-title":"En bloc resection and vascularized ulnar pedicle graft reconstruction with plate fixation for giant cell tumour of the distal radius","volume":"47","year":"2022","journal-title":"J. Hand Surg."},{"issue":"2","key":"2025061108373963900_c27","doi-asserted-by":"publisher","first-page":"93","DOI":"10.4186\/ej.2025.29.2.93","article-title":"Finite element analysis-based pre-operative application for biomechanical evaluation of a locking plate used in reconstruction after en bloc resection of a stage 3 giant cell tumor of the distal radius","volume":"29","year":"2025","journal-title":"Eng. J."},{"issue":"6","key":"2025061108373963900_c28","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1016\/j.bone.2010.08.012","article-title":"Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone","volume":"47","year":"2010","journal-title":"Bone"},{"key":"2025061108373963900_c29","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.promfg.2020.03.070","article-title":"Torque control during bone insertion of cortical screws","volume":"46","year":"2020","journal-title":"Procedia Manuf."},{"key":"2025061108373963900_c30","article-title":"Specification and test methods for metallic medical bone screws","author":"ASTM"},{"issue":"10","key":"2025061108373963900_c31","doi-asserted-by":"publisher","first-page":"1064","DOI":"10.1080\/10255842.2020.1867114","article-title":"A comparative finite element simulation of locking compression plate materials for tibial fracture treatment","volume":"24","year":"2021","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2025061108373963900_c32","doi-asserted-by":"publisher","DOI":"10.1201\/b14263","article-title":"Mechanical properties of cortical bone and cancellous bone tissue","volume-title":"Bone Mechanics Handbook","year":"2001"},{"issue":"4","key":"2025061108373963900_c33","doi-asserted-by":"publisher","first-page":"824","DOI":"10.1016\/j.bone.2012.01.012","article-title":"Ct-based finite element models can be used to estimate experimentally measured failure loads in the proximal femur","volume":"50","year":"2012","journal-title":"Bone"},{"issue":"6","key":"2025061108373963900_c34","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1590\/0103-6440201300639","article-title":"Reliability of FEA on the results of mechanical properties of materials","volume":"26","year":"2015","journal-title":"Braz. Dent. J."},{"key":"2025061108373963900_c35","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.bonr.2018.04.001","article-title":"Distal radius microstructure and finite element bone strain are related to site-specific mechanical loading and areal bone mineral density in premenopausal women","volume":"8","year":"2018","journal-title":"Bone Rep."},{"issue":"9","key":"2025061108373963900_c36","doi-asserted-by":"publisher","first-page":"e3617","DOI":"10.1002\/cnm.3617","article-title":"Analysis and validation of a 3D finite element model for human forearm fracture","volume":"38","year":"2022","journal-title":"Numer. Methods Biomed. Eng."},{"issue":"5","key":"2025061108373963900_c37","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3390\/life12050740","article-title":"Variations in strain distribution at distal radius under different loading conditions","volume":"12","year":"2022","journal-title":"Life"},{"issue":"11","key":"2025061108373963900_c38","doi-asserted-by":"publisher","first-page":"2672","DOI":"10.1016\/j.jbiomech.2014.05.010","article-title":"The effect of static muscle forces on the fracture strength of the intact distal radius in vitro in response to simulated forward fall impacts","volume":"47","year":"2014","journal-title":"J. Biomech."},{"issue":"6","key":"2025061108373963900_c39","doi-asserted-by":"publisher","first-page":"1271","DOI":"10.1016\/j.injury.2020.03.011","article-title":"Biomechanical Investigation of a novel hybrid dorsal double plating for distal radius fractures by integrating topology optimization and finite element analysis","volume":"51","year":"2020","journal-title":"Injury"},{"issue":"6","key":"2025061108373963900_c40","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.1053\/j.jfas.2018.10.005","article-title":"Biomechanical comparison of locking plate and cancellous screw techniques in medial malleolar fractures: A finite element analysis","volume":"58","year":"2019","journal-title":"J. Foot Ankle Surg."},{"issue":"8","key":"2025061108373963900_c41","doi-asserted-by":"publisher","first-page":"775","DOI":"10.2106\/JBJS.938ebo","article-title":"American academy of orthopaedic surgeons clinical practice guideline on: The treatment of distal radius fractures","volume":"93","year":"2011","journal-title":"J. Bone Jt. Surg."}],"container-title":["APL Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0248553\/20554729\/026123_1_5.0248553.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0248553\/20554729\/026123_1_5.0248553.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,11]],"date-time":"2025-06-11T12:37:46Z","timestamp":1749645466000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/apb\/article\/9\/2\/026123\/3349446\/Evaluation-of-screw-pull-out-from-plate-fixation"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,1]]},"references-count":41,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025,6,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0248553","relation":{},"ISSN":["2473-2877"],"issn-type":[{"value":"2473-2877","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,6,1]]},"published":{"date-parts":[[2025,6,1]]},"article-number":"026123"}}