{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T15:15:38Z","timestamp":1792336538339,"version":"4.4.0"},"reference-count":84,"publisher":"AIP Publishing","issue":"4","license":[{"start":{"date-parts":[[2025,10,18]],"date-time":"2025-10-18T00:00:00Z","timestamp":1760745600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["5R21EY033086-02"],"award-info":[{"award-number":["5R21EY033086-02"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Caltech Center for Sensing to Intelligence","award":["13630012"],"award-info":[{"award-number":["13630012"]}]},{"name":"USC Neurorestoration Center"},{"name":"2024 SPIE-Franz Hillenkamp Postdoctoral Fellowship"}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12,1]]},"abstract":"<jats:p>Cerebral blood flow is a critical metric for cerebrovascular monitoring, with applications in stroke detection, brain injury evaluation, aging, and neurological disorders. Noninvasively measuring cerebral blood dynamics is challenging due to the presence of scalp and skull, which obstruct direct brain access and contain their own blood dynamics that must be isolated. We developed an aggregated seven-channel speckle contrast optical spectroscopy (SCOS) system to measure blood flow and blood volume noninvasively. Each channel, with a distinct source-to-detector distance, targeted different depths to detect scalp and brain blood dynamics separately. By briefly occluding the superficial temporal artery, which supplies blood only to the scalp, we isolated surface blood dynamics from brain signals. Results on 20 subjects show that scalp-sensitive channels experienced significant reductions in blood dynamics during occlusion, while brain-sensitive channels experienced minimal changes. This provides experimental evidence of scalp blood flow sensitivity in diffuse optical measurements such as SCOS, highlighting optimal configuration for preferentially probing brain signals noninvasively.<\/jats:p>","DOI":"10.1063\/5.0263953","type":"journal-article","created":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T14:45:34Z","timestamp":1761057934000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":4,"title":["Assessing human scalp and brain blood flow sensitivities via superficial temporal artery occlusion using speckle contrast optical spectroscopy"],"prefix":"10.1063","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0009-0000-0165-2084","authenticated-orcid":false,"given":"Yu Xi","family":"Huang","sequence":"first","affiliation":[{"name":"Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9761-445X","authenticated-orcid":false,"given":"Simon","family":"Mahler","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-8983-1190","authenticated-orcid":false,"given":"Maya","family":"Dickson","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8243-3878","authenticated-orcid":false,"given":"Aidin","family":"Abedi","sequence":"additional","affiliation":[{"name":"USC Neurorestoration Center, Department of Neurological Surgery, Keck School of Medicine, University of Southern California 2 , Los Angeles, California 90033,","place":["USA"]},{"name":"Rancho Research Institute, Rancho Los Amigos National Rehabilitation Center 3 , Downey, California 90242,","place":["USA"]},{"name":"Department of Urology, University of Toledo College of Medicine and Life Sciences 4 , Toledo, Ohio 43614,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4234-8991","authenticated-orcid":false,"given":"Yu Tung","family":"Lo","sequence":"additional","affiliation":[{"name":"USC Neurorestoration Center, Department of Neurological Surgery, Keck School of Medicine, University of Southern California 2 , Los Angeles, California 90033,","place":["USA"]},{"name":"Department of Neurosurgery, National Neuroscience Institute 5 , 308433","place":["Singapore"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6170-4042","authenticated-orcid":false,"given":"Patrick D.","family":"Lyden","sequence":"additional","affiliation":[{"name":"Department of Physiology and Neuroscience, Zilkha Neurogenetic Institute, and Department of Neurology, Keck School of Medicine, University of Southern California 6 , Los Angeles, California 90033,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5304-4977","authenticated-orcid":false,"given":"Jonathan","family":"Russin","sequence":"additional","affiliation":[{"name":"USC Neurorestoration Center, Department of Neurological Surgery, Keck School of Medicine, University of Southern California 2 , Los Angeles, California 90033,","place":["USA"]},{"name":"Rancho Research Institute, Rancho Los Amigos National Rehabilitation Center 3 , Downey, California 90242,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6423-8577","authenticated-orcid":false,"given":"Charles","family":"Liu","sequence":"additional","affiliation":[{"name":"USC Neurorestoration Center, Department of Neurological Surgery, Keck School of Medicine, University of Southern California 2 , Los Angeles, California 90033,","place":["USA"]},{"name":"Rancho Research Institute, Rancho Los Amigos National Rehabilitation Center 3 , Downey, California 90242,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8791-0354","authenticated-orcid":false,"given":"Changhuei","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering, California Institute of Technology 1 , Pasadena, California 91125,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2025,10,21]]},"reference":[{"key":"2025102110452925700_c1","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1007\/978-981-99-8059-8","volume-title":"Principles and Practice of Neurocritical Care","author":"Prabhakar","year":"2024"},{"key":"2025102110452925700_c2","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1136\/jnnp.61.2.166","article-title":"Dynamics of cerebral blood flow and metabolism in patients with cranioplasty as evaluated by 133Xe CT and 31P magnetic resonance spectroscopy","volume":"61","year":"1996","journal-title":"J. Neurol., Neurosurg. Psychiatry"},{"key":"2025102110452925700_c3","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1002\/ana.410290302","article-title":"Cerebral hemodynamics in ischemic cerebrovascular disease","volume":"29","year":"1991","journal-title":"Ann. Neurol."},{"key":"2025102110452925700_c4","first-page":"285","volume-title":"International Review of Neurobiology","year":"2005"},{"key":"2025102110452925700_c5","doi-asserted-by":"publisher","first-page":"S11","DOI":"10.1016\/S0720-048X(02)00359-5","article-title":"Brain perfusion CT in acute stroke: Current status","volume":"45","year":"2003","journal-title":"Eur. J. Radiol."},{"key":"2025102110452925700_c6","doi-asserted-by":"publisher","first-page":"627994","DOI":"10.3389\/fnins.2021.627994","article-title":"Illuminating the brain with X-rays: Contributions and future perspectives of high-resolution microtomography to neuroscience","volume":"15","year":"2021","journal-title":"Front. Neurosci."},{"key":"2025102110452925700_c7","first-page":"59","article-title":"Functional neuroimaging: A brief overview and feasibility for use in chiropractic research","volume":"53","year":"2009","journal-title":"J. Can. Chiropr. Assoc."},{"key":"2025102110452925700_c8","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1136\/heartjnl-2017-312731","article-title":"Resting heart rate: What is normal?","volume":"104","year":"2018","journal-title":"Heart"},{"key":"2025102110452925700_c9","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1016\/j.jelectrocard.2010.07.007","article-title":"A review of electrocardiogram filtering","volume":"43","year":"2010","journal-title":"J. Electrocardiol."},{"key":"2025102110452925700_c10","first-page":"41","volume-title":"First International Conference on Advances in Medical Signal and Information Processing","year":"2000"},{"key":"2025102110452925700_c11","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/0002-8703(72)90412-7","article-title":"The phases of the cardiac cycle","volume":"83","year":"1972","journal-title":"Am. Heart J."},{"key":"2025102110452925700_c12","doi-asserted-by":"publisher","first-page":"108283","DOI":"10.1016\/j.cmpb.2024.108283","article-title":"An algorithm to detect dicrotic notch in arterial blood pressure and photoplethysmography waveforms using the iterative envelope mean method","volume":"254","year":"2024","journal-title":"Comput. Methods Programs Biomed."},{"key":"2025102110452925700_c13","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/s10916-014-0054-9","article-title":"Hiding patients confidential data in the ECG signal via transform-domain quantization scheme","volume":"38","year":"2014","journal-title":"J. Med. Syst."},{"key":"2025102110452925700_c14","doi-asserted-by":"publisher","first-page":"012015","DOI":"10.1088\/1742-6596\/1230\/1\/012015","article-title":"Abnormalities state detection from P-wave, QRS complex, and T-wave in noisy ECG","volume":"1230","year":"2019","journal-title":"J. Phys.: Conf. Ser."},{"key":"2025102110452925700_c15","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1161\/01.STR.26.7.1234","article-title":"Evaluation of the acetazolamide test: Vasoreactivity and cerebral blood volume","volume":"26","year":"1995","journal-title":"Stroke"},{"key":"2025102110452925700_c16","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.3174\/ajnr.A1129","article-title":"Quantitative cerebrovascular reserve measured by acetazolamide-challenged dynamic CT perfusion in ischemic adult Moyamoya disease: Initial experience with angiographic correlation","volume":"29","year":"2008","journal-title":"Am. J. Neuroradiol."},{"key":"2025102110452925700_c17","doi-asserted-by":"publisher","first-page":"876","DOI":"10.3174\/ajnr.A1538","article-title":"The acetazolamide challenge: Techniques and applications in the evaluation of chronic cerebral ischemia","volume":"30","year":"2009","journal-title":"Am. J. Neuroradiol."},{"key":"2025102110452925700_c18","doi-asserted-by":"publisher","first-page":"096601","DOI":"10.1088\/0034-4885\/76\/9\/096601","article-title":"The physics of functional magnetic resonance imaging (fMRI)","volume":"76","year":"2013","journal-title":"Rep. Prog. Phys."},{"key":"2025102110452925700_c19","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1038\/nm0298-159","article-title":"Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging","volume":"4","year":"1998","journal-title":"Nat. Med."},{"key":"2025102110452925700_c20","doi-asserted-by":"publisher","first-page":"690","DOI":"10.1038\/sj.jcbfm.9600409","article-title":"Dynamics of changes in blood flow, volume, and oxygenation: Implications for dynamic functional magnetic resonance imaging calibration","volume":"27","year":"2007","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"2025102110452925700_c21","doi-asserted-by":"publisher","first-page":"2553","DOI":"10.1109\/TBME.2015.2481482","article-title":"Real-time neuroimaging and cognitive monitoring using wearable dry EEG","volume":"62","year":"2015","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"2025102110452925700_c22","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1016\/j.neuroimage.2017.11.062","article-title":"EEG microstates as a tool for studying the temporal dynamics of whole-brain neuronal networks: A review","volume":"180","year":"2018","journal-title":"NeuroImage"},{"key":"2025102110452925700_c23","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1055\/s-0032-1331812","article-title":"Transcranial Doppler ultrasound: Technique and application","volume":"32","year":"2013","journal-title":"Semin. Neurol."},{"key":"2025102110452925700_c24","doi-asserted-by":"publisher","first-page":"eadj3143","DOI":"10.1126\/scitranslmed.adj3143","article-title":"Functional ultrasound imaging of human brain activity through an acoustically transparent cranial window","volume":"16","year":"2024","journal-title":"Sci. Transl. Med."},{"key":"2025102110452925700_c25","doi-asserted-by":"publisher","first-page":"015008","DOI":"10.1117\/1.NPh.11.1.015008","article-title":"Validation of the Openwater wearable optical system: Cerebral hemodynamic monitoring during a breath-hold maneuver","volume":"11","year":"2024","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c26","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1109\/TUFFC.2022.3148121","article-title":"Refraction-corrected transcranial ultrasound imaging through the human temporal window using a single probe","volume":"69","year":"2022","journal-title":"IEEE Trans. Ultrason., Ferroelect., Freq. Contr."},{"key":"2025102110452925700_c27","doi-asserted-by":"publisher","first-page":"6083","DOI":"10.1364\/BOE.534796","article-title":"Correlating stroke risk with non-invasive cerebrovascular perfusion dynamics using a portable speckle contrast optical spectroscopy laser device","volume":"15","year":"2024","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c28","doi-asserted-by":"publisher","first-page":"067001","DOI":"10.1117\/1.JBO.29.6.067001","article-title":"Compact and cost-effective laser-powered speckle contrast optical spectroscopy fiber-free device for measuring cerebral blood flow","volume":"29","year":"2024","journal-title":"J. Biomed. Opt."},{"key":"2025102110452925700_c29","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1038\/s42003-023-05211-4","article-title":"Measuring human cerebral blood flow and brain function with fiber-based speckle contrast optical spectroscopy system","volume":"6","year":"2023","journal-title":"Commun. Biol."},{"key":"2025102110452925700_c30","doi-asserted-by":"publisher","first-page":"2769","DOI":"10.1364\/BOE.5.002769","article-title":"Speckle contrast optical spectroscopy, a non-invasive, diffuse optical method for measuring microvascular blood flow in tissue","volume":"5","year":"2014","journal-title":"Biomed. Opt. Express"},{"issue":"4","key":"2025102110452925700_c31","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1136\/jnis-2024-021536","article-title":"Portable cerebral blood flow monitor to detect large vessel occlusion in patients with suspected stroke","volume":"17","year":"2025","journal-title":"J. NeuroIntervent. Surg."},{"key":"2025102110452925700_c32","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1364\/BOE.9.000322","article-title":"Compact, multi-exposure speckle contrast optical spectroscopy (SCOS) device for measuring deep tissue blood flow","volume":"9","year":"2018","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c33","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1364\/OL.478956","article-title":"Multi-mode fiber-based speckle contrast optical spectroscopy: Analysis of speckle statistics","volume":"48","year":"2023","journal-title":"Opt. Lett."},{"key":"2025102110452925700_c34","doi-asserted-by":"publisher","first-page":"31253","DOI":"10.1364\/OE.499473","article-title":"Interferometric speckle visibility spectroscopy (iSVS) for measuring decorrelation time and dynamics of moving samples with enhanced signal-to-noise ratio and relaxed reference requirements","volume":"31","year":"2023","journal-title":"Opt. Express"},{"key":"2025102110452925700_c35","doi-asserted-by":"publisher","first-page":"4964","DOI":"10.1364\/BOE.498815","article-title":"Assessing depth sensitivity in laser interferometry speckle visibility spectroscopy (iSVS) through source-to-detector distance variation and cerebral blood flow monitoring in humans and rabbits","volume":"14","year":"2023","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c36","doi-asserted-by":"publisher","first-page":"126102","DOI":"10.1063\/5.0021988","article-title":"Interferometric speckle visibility spectroscopy (ISVS) for human cerebral blood flow monitoring","volume":"5","year":"2020","journal-title":"APL Photonics"},{"key":"2025102110452925700_c37","doi-asserted-by":"publisher","first-page":"016105","DOI":"10.1063\/5.0034576","article-title":"Diffusing wave spectroscopy: A unified treatment on temporal sampling and speckle ensemble methods","volume":"6","year":"2021","journal-title":"APL Photonics"},{"key":"2025102110452925700_c38","doi-asserted-by":"publisher","first-page":"4605","DOI":"10.1364\/BOE.530366","article-title":"Non-invasive laser speckle contrast imaging (LSCI) of extra-embryonic blood vessels in intact avian eggs at early developmental stages","volume":"15","year":"2024","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c39","doi-asserted-by":"publisher","first-page":"093110","DOI":"10.1063\/1.2037987","article-title":"Speckle-visibility spectroscopy: A tool to study time-varying dynamics","volume":"76","year":"2005","journal-title":"Rev. Sci. Instrum."},{"key":"2025102110452925700_c40","doi-asserted-by":"publisher","first-page":"015004","DOI":"10.1117\/1.NPh.11.1.015004","article-title":"Comparing the performance potential of speckle contrast optical spectroscopy and diffuse correlation spectroscopy for cerebral blood flow monitoring using Monte Carlo simulations in realistic head geometries","volume":"11","year":"2024","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c41","doi-asserted-by":"publisher","first-page":"015003","DOI":"10.1117\/1.NPh.12.1.015003","article-title":"Portable six-channel laser speckle system for simultaneous measurement of cerebral blood flow and volume with potential applications in characterization of brain injury","volume":"12","year":"2025","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c42","doi-asserted-by":"publisher","first-page":"e66319","DOI":"10.1371\/journal.pone.0066319","article-title":"Depth sensitivity and source-detector separations for near infrared spectroscopy based on the Colin27 brain template","volume":"8","year":"2013","journal-title":"PLoS One"},{"key":"2025102110452925700_c43","doi-asserted-by":"publisher","first-page":"eabe0150","DOI":"10.1126\/sciadv.abe0150","article-title":"Functional interferometric diffusing wave spectroscopy of the human brain","volume":"7","year":"2021","journal-title":"Sci. Adv."},{"key":"2025102110452925700_c44","doi-asserted-by":"publisher","first-page":"e26377","DOI":"10.1371\/journal.pone.0026377","article-title":"Simulation of near-infrared light absorption considering individual head and prefrontal cortex anatomy: Implications for optical neuroimaging","volume":"6","year":"2011","journal-title":"PLoS One"},{"key":"2025102110452925700_c45","doi-asserted-by":"publisher","first-page":"4792","DOI":"10.1364\/BOE.9.004792","article-title":"Establishing the quantitative relationship between diffuse speckle contrast analysis signals with absolute blood flow","volume":"9","year":"2018","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c46","doi-asserted-by":"publisher","first-page":"1076","DOI":"10.1038\/jcbfm.2015.84","article-title":"Expanding applications, accuracy, and interpretation of laser speckle contrast imaging of cerebral blood flow","volume":"35","year":"2015","journal-title":"J. Cereb. Blood Flow Metab."},{"key":"2025102110452925700_c47","doi-asserted-by":"publisher","first-page":"5382","DOI":"10.1364\/OL.570951","article-title":"Optimized cerebral blood flow measurement in speckle contrast optical spectroscopy via refinement of noise calibration","volume":"50","year":"2025","journal-title":"Opt. Lett."},{"key":"2025102110452925700_c48","doi-asserted-by":"publisher","first-page":"015001","DOI":"10.1117\/1.NPh.8.1.015001","article-title":"Improved accuracy of cerebral blood flow quantification in the presence of systemic physiology cross-talk using multi-layer Monte Carlo modeling","volume":"8","year":"2021","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c49","doi-asserted-by":"publisher","first-page":"045002","DOI":"10.1117\/1.NPh.7.4.045002","article-title":"Direct assessment of extracerebral signal contamination on optical measurements of cerebral blood flow, oxygenation, and metabolism","volume":"7","year":"2020","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c50","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1364\/OPTICA.472471","article-title":"Interferometric diffusing wave spectroscopy imaging with an electronically variable time-of-flight filter","volume":"10","year":"2023","journal-title":"Optica"},{"key":"2025102110452925700_c51","doi-asserted-by":"publisher","first-page":"932119","DOI":"10.3389\/fnins.2022.932119","article-title":"Functional time domain diffuse correlation spectroscopy","volume":"16","year":"2022","journal-title":"Front. Neurosci."},{"key":"2025102110452925700_c52","doi-asserted-by":"publisher","first-page":"8803","DOI":"10.1038\/s41598-023-36074-8","article-title":"Portable, high speed blood flow measurements enabled by long wavelength, interferometric diffuse correlation spectroscopy (LW-iDCS)","volume":"13","year":"2023","journal-title":"Sci. Rep."},{"key":"2025102110452925700_c53","doi-asserted-by":"publisher","first-page":"817","DOI":"10.3390\/metabo12090817","article-title":"Assessing the sensitivity of multi-distance hyperspectral NIRS to changes in the oxidation state of cytochrome C oxidase in the brain","volume":"12","year":"2022","journal-title":"Metabolites"},{"key":"2025102110452925700_c54","doi-asserted-by":"publisher","first-page":"7400814","DOI":"10.1109\/JSTQE.2025.3575719","article-title":"Pathlength-selective, interferometric diffuse correlation spectroscopy","volume":"31","year":"2025","journal-title":"IEEE J. Sel. Top. Quantum Electron."},{"key":"2025102110452925700_c55","volume-title":"American National Standard for Safe Use of Lasers","author":"Laser Institute of America","year":"2014"},{"key":"2025102110452925700_c56","doi-asserted-by":"publisher","first-page":"015005","DOI":"10.1117\/1.NPh.1.1.015005","article-title":"Sensitivity of near-infrared spectroscopy and diffuse correlation spectroscopy to brain hemodynamics: Simulations and experimental findings during hypercapnia","volume":"1","year":"2014","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c57","doi-asserted-by":"publisher","first-page":"1365","DOI":"10.3390\/brainsci13101365","article-title":"Non-invasive continuous optical monitoring of cerebral blood flow after traumatic brain injury in mice using fiber camera-based speckle contrast optical spectroscopy","volume":"13","year":"2023","journal-title":"Brain Sci."},{"key":"2025102110452925700_c58","doi-asserted-by":"publisher","first-page":"035010","DOI":"10.1117\/1.NPh.7.3.035010","article-title":"High-sensitivity multispeckle diffuse correlation spectroscopy","volume":"7","year":"2020","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c59","doi-asserted-by":"publisher","first-page":"013509","DOI":"10.1117\/1.NPh.10.1.013509","article-title":"Diffuse correlation spectroscopy: Current status and future outlook","volume":"10","year":"2023","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c60","doi-asserted-by":"publisher","first-page":"031412","DOI":"10.1117\/1.NPh.3.3.031412","article-title":"Establishing the diffuse correlation spectroscopy signal relationship with blood flow","volume":"3","year":"2016","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c61","doi-asserted-by":"publisher","first-page":"011009","DOI":"10.1117\/1.NPh.1.1.011009","article-title":"Diffuse correlation spectroscopy for measurement of cerebral blood flow: Future prospects","volume":"1","year":"2014","journal-title":"Neurophotonics"},{"key":"2025102110452925700_c62","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1364\/BOE.410248","article-title":"Direct measurement of the scattering coefficient","volume":"12","year":"2021","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c63","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1016\/j.neuroimage.2013.06.017","article-title":"Diffuse correlation spectroscopy for non-invasive, micro-vascular cerebral blood flow measurement","volume":"85","year":"2014","journal-title":"NeuroImage"},{"key":"2025102110452925700_c64","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1364\/OL.29.001766","article-title":"Diffuse optical measurement of blood flow, blood oxygenation, and metabolism in a human brain during sensorimotor cortex activation","volume":"29","year":"2004","journal-title":"Opt. Lett."},{"key":"2025102110452925700_c65","doi-asserted-by":"publisher","first-page":"011109","DOI":"10.1117\/1.3285504","article-title":"Laser speckle contrast imaging in biomedical optics","volume":"15","year":"2010","journal-title":"J. Biomed. Opt."},{"key":"2025102110452925700_c66","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.ydbio.2024.12.005","article-title":"Automated non-invasive laser speckle imaging of the chick heart rate and extraembryonic blood vessels and their response to Nifedipine and Amlodipine drugs","volume":"519","year":"2025","journal-title":"Dev. Biol."},{"key":"2025102110452925700_c67","doi-asserted-by":"publisher","first-page":"639","DOI":"10.1007\/s10103-008-0626-3","article-title":"Review of laser speckle contrast techniques for visualizing tissue perfusion","volume":"24","year":"2009","journal-title":"Lasers Med. Sci."},{"key":"2025102110452925700_c68","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1109\/RBME.2013.2243140","article-title":"Laser speckle contrast imaging: Theory, instrumentation and applications","volume":"6","year":"2013","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"2025102110452925700_c69","doi-asserted-by":"publisher","first-page":"023812","DOI":"10.1103\/PhysRevA.98.023812","article-title":"Spatiotemporal supermodes: Rapid reduction of spatial coherence in highly multimode lasers","volume":"98","year":"2018","journal-title":"Phys. Rev. A"},{"key":"2025102110452925700_c70","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1515\/nanoph-2020-0390","article-title":"Fast laser speckle suppression with an intracavity diffuser","volume":"10","year":"2020","journal-title":"Nanophotonics"},{"key":"2025102110452925700_c71","doi-asserted-by":"publisher","first-page":"143901","DOI":"10.1103\/PhysRevLett.128.143901","article-title":"Controlling nonlinear interaction in a many-mode laser by tuning disorder","volume":"128","year":"2022","journal-title":"Phys. Rev. Lett."},{"key":"2025102110452925700_c72","doi-asserted-by":"publisher","first-page":"033527","DOI":"10.1103\/PhysRevA.105.033527","article-title":"Real-time full-field imaging through scattering media by all-optical feedback","volume":"105","year":"2022","journal-title":"Phys. Rev. A"},{"key":"2025102110452925700_c73","doi-asserted-by":"publisher","first-page":"6533","DOI":"10.1364\/BOE.472263","article-title":"Model of dynamic speckle evolution for evaluating laser speckle contrast measurements of tissue dynamics","volume":"13","year":"2022","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c74","doi-asserted-by":"publisher","first-page":"11915","DOI":"10.1038\/s41598-024-62106-y","article-title":"Choosing a camera and optimizing system parameters for speckle contrast optical spectroscopy","volume":"14","year":"2024","journal-title":"Sci. Rep."},{"key":"2025102110452925700_c75","doi-asserted-by":"publisher","first-page":"013001","DOI":"10.1088\/2040-8986\/ac3a9d","article-title":"Roadmap on multimode light shaping","volume":"24","year":"2022","journal-title":"J. Opt."},{"key":"2025102110452925700_c76","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1364\/OPN.33.5.000026","article-title":"Complex-light lasers","volume":"33","year":"2022","journal-title":"Opt. Photonics News"},{"key":"2025102110452925700_c77","doi-asserted-by":"publisher","first-page":"e201700123","DOI":"10.1002\/jbio.201700123","article-title":"Assessment of the dynamics of human glymphatic system by near-infrared spectroscopy","volume":"11","year":"2018","journal-title":"J. Biophotonics"},{"key":"2025102110452925700_c78","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1007\/s10103-010-0754-4","article-title":"Depth sensitivity analysis of functional near-infrared spectroscopy measurement using three-dimensional Monte Carlo modelling-based magnetic resonance imaging","volume":"25","year":"2010","journal-title":"Lasers Med. Sci."},{"key":"2025102110452925700_c79","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1364\/OPTICA.5.000518","article-title":"Highly parallel, interferometric diffusing wave spectroscopy for monitoring cerebral blood flow dynamics","volume":"5","year":"2018","journal-title":"Optica"},{"key":"2025102110452925700_c80","doi-asserted-by":"publisher","first-page":"3571","DOI":"10.1112\/plms\/s1-29.1.353","article-title":"On the calculation of the most probable values of frequency-constants, for data arranged according to equidistant division of a scale","volume":"s1-29","year":"1897","journal-title":"Proc. London Math. Soc."},{"key":"2025102110452925700_c81","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1364\/BOE.502421","article-title":"Comprehensive workflow and its validation for simulating diffuse speckle statistics for optical blood flow measurements","volume":"15","year":"2024","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c82","doi-asserted-by":"publisher","first-page":"3571","DOI":"10.1364\/BOE.426521","article-title":"Choosing a model for laser speckle contrast imaging","volume":"12","year":"2021","journal-title":"Biomed. Opt. Express"},{"key":"2025102110452925700_c83","doi-asserted-by":"publisher","first-page":"eabc4628","DOI":"10.1126\/sciadv.abc4628","article-title":"Dynamic light scattering imaging","volume":"6","year":"2020","journal-title":"Sci. Adv."},{"key":"2025102110452925700_c84","doi-asserted-by":"publisher","first-page":"1130","DOI":"10.1002\/ca.23550","article-title":"The superficial temporal artery: A meta-analysis of its prevalence and morphology","volume":"33","year":"2020","journal-title":"Clin. Anat."}],"container-title":["APL Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0263953\/20766021\/046106_1_5.0263953.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0263953\/20766021\/046106_1_5.0263953.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T14:45:36Z","timestamp":1761057936000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/apb\/article\/9\/4\/046106\/3368590\/Assessing-human-scalp-and-brain-blood-flow"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,21]]},"references-count":84,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,12,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0263953","relation":{},"ISSN":["2473-2877"],"issn-type":[{"value":"2473-2877","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,12,1]]},"published":{"date-parts":[[2025,10,21]]},"article-number":"046106"}}