{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T02:33:20Z","timestamp":1791254000471,"version":"4.1.0"},"reference-count":23,"publisher":"AIP Publishing","issue":"4","license":[{"start":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T00:00:00Z","timestamp":1758758400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010677","name":"H2020 Health","doi-asserted-by":"publisher","award":["101017523"],"award-info":[{"award-number":["101017523"]}],"id":[{"id":"10.13039\/100010677","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000780","name":"European Commission","doi-asserted-by":"publisher","award":["PNC0000003"],"award-info":[{"award-number":["PNC0000003"]}],"id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100031478","name":"NextGenerationEU","doi-asserted-by":"publisher","award":["B53C22006700001"],"award-info":[{"award-number":["B53C22006700001"]}],"id":[{"id":"10.13039\/100031478","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,12,1]]},"abstract":"<jats:p>Transcatheter aortic valve implantation (TAVI) has become a standardized treatment for aortic valve stenosis, supported by computational modeling to enhance procedural planning. However, the credibility of TAVI simulations requires rigorous validation following regulatory standards. This study aims to perform a population-based validation of the structural and hemodynamic simulation performance of the SAPIEN 3 (S3) Ultra device by comparing computational predictions with clinical post-TAVI data, following the ASME V&amp;V 40 framework. A patient-specific structural model followed by fluid\u2013structure interaction was developed to simulate S3 deployment and then assess post-TAVI hemodynamics in 20 patients. Structural parameters (device diameters) and hemodynamic indices (effective orifice area, EOA, and transmural pressure gradient, TPG) were extracted. Validation was performed using empirical cumulative distribution function (ECDF) analysis, with an acceptance threshold of 5% for model credibility. EOA and TPG predictions showed reasonable agreement with echocardiographic data (errors within 10%). ECDF-based comparison demonstrated a high level of accuracy for device diameters (\u22645% area metric), whereas hemodynamic parameters exhibited slightly greater discrepancies, potentially due to clinical measurement variability. This study establishes a robust computational validation framework for patient-specific TAVI modeling, ensuring regulatory compliance and clinical applicability. These findings highlight the potential of in silico trials to support TAVI planning and decision-making. This study is complemented by a second part dedicated to uncertainty quantification and sensitivity analysis.<\/jats:p>","DOI":"10.1063\/5.0280958","type":"journal-article","created":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T17:27:05Z","timestamp":1758821225000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":11,"title":["Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation. I. A population-based validation of patient-specific modeling"],"prefix":"10.1063","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6567-061X","authenticated-orcid":false,"given":"Chiara","family":"Catalano","sequence":"first","affiliation":[{"name":"Department of Engineering, Universit\u00e0 degli Studi di Palermo 1 , Viale delle Scienze Ed. 8, Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberta","family":"Scuoppo","sequence":"additional","affiliation":[{"name":"Department of Engineering, Universit\u00e0 degli Studi di Palermo 1 , Viale delle Scienze Ed. 8, Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-9472-4529","authenticated-orcid":false,"given":"Tahir","family":"Turgut","sequence":"additional","affiliation":[{"name":"4RealSim Services BV 2 , Groene Dijk 2B, 3401 NJ IJsselstein,","place":["Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-5142-5737","authenticated-orcid":false,"given":"Vincent","family":"Bouwman","sequence":"additional","affiliation":[{"name":"4RealSim Services BV 2 , Groene Dijk 2B, 3401 NJ IJsselstein,","place":["Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-7132-0783","authenticated-orcid":false,"given":"Nils","family":"G\u00f6tzen","sequence":"additional","affiliation":[{"name":"4RealSim Services BV 2 , Groene Dijk 2B, 3401 NJ IJsselstein,","place":["Netherlands"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefano","family":"Cannata","sequence":"additional","affiliation":[{"name":"Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta Specializzazione) 3 , Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3767-815X","authenticated-orcid":false,"given":"Giovanni","family":"Gentile","sequence":"additional","affiliation":[{"name":"Radiology Unit, Department of Diagnostic and Therapeutic Services, IRCCS ISMETT 4 , via Tricomi, 5, Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6049-8961","authenticated-orcid":false,"given":"Caterina","family":"Gandolfo","sequence":"additional","affiliation":[{"name":"Department for the Treatment and Study of Cardiothoracic Diseases and Cardiothoracic Transplantation, IRCCS-ISMETT (Istituto Mediterraneo per i Trapianti e Terapie ad alta Specializzazione) 3 , Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4841-2560","authenticated-orcid":false,"given":"Salvatore","family":"Pasta","sequence":"additional","affiliation":[{"name":"Department of Engineering, Universit\u00e0 degli Studi di Palermo 1 , Viale delle Scienze Ed. 8, Palermo,","place":["Italy"]},{"name":"Department of Research, IRCCS ISMETT 5 , via Tricomi, 5, Palermo,","place":["Italy"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2025,9,25]]},"reference":[{"key":"2025092513265535000_c1","doi-asserted-by":"publisher","first-page":"2625","DOI":"10.1093\/eurheartj\/ehy244","article-title":"Transcatheter aortic valve implantation: Current status and future perspectives","volume":"39","year":"2018","journal-title":"Eur. Heart J."},{"key":"2025092513265535000_c2","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1093\/ejcts\/ezab389","article-title":"2021 ESC\/EACTS Guidelines for the management of valvular heart disease: Developed by the Task Force for the management of valvular heart disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"60","year":"2021","journal-title":"Eur. J. Cardiothorac. Surg."},{"key":"2025092513265535000_c3","doi-asserted-by":"publisher","first-page":"3006","DOI":"10.1161\/01.CIR.0000047200.36165.B8","article-title":"Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description","volume":"106","year":"2002","journal-title":"Circulation"},{"key":"2025092513265535000_c4","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s13239-019-00427-0","article-title":"On the modeling of patient-specific transcatheter aortic valve replacement: A fluid\u2013structure interaction approach","volume":"10","year":"2019","journal-title":"Cardiovasc. Eng. Technol."},{"key":"2025092513265535000_c5","doi-asserted-by":"publisher","first-page":"6762","DOI":"10.1038\/s41598-024-57177-w","article-title":"Smoothed particle hydrodynamics based FSI simulation of the native and mechanical heart valves in a patient-specific aortic model","volume":"14","year":"2024","journal-title":"Sci. Rep."},{"key":"2025092513265535000_c6","article-title":"Assessing credibility of computational modeling through verification and validation: Application to medical devices","volume-title":"ASME V&V 40-2018","author":"(ASME) TASoME","year":"2018"},{"key":"2025092513265535000_c7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-66899-6","article-title":"A validated computational framework to predict outcomes in TAVI","volume":"10","year":"2020","journal-title":"Sci. Rep."},{"key":"2025092513265535000_c8","doi-asserted-by":"publisher","first-page":"109159","DOI":"10.1016\/j.compbiomed.2024.109159","article-title":"Validation evidence with experimental and clinical data to establish credibility of TAVI patient-specific simulations","volume":"182","year":"2024","journal-title":"Comput. Biol. Med."},{"key":"2025092513265535000_c9","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1007\/s13239-023-00699-7","article-title":"On the material constitutive behavior of the aortic root in patients with transcatheter aortic valve implantation","volume":"15","year":"2024","journal-title":"Cardiovasc. Eng. Technol."},{"issue":"4","key":"2025092513265535000_c10","doi-asserted-by":"publisher","first-page":"046102","DOI":"10.1063\/5.0280959","article-title":"Credibility assessment of patient-specific modeling in transcatheter aortic valve implantation\u2014Part 2: Uncertainty quantification and sensitivity analysis","volume":"9","year":"2025","journal-title":"APL Bioeng."},{"key":"2025092513265535000_c11","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.medengphy.2017.06.045","article-title":"Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes","volume":"47","year":"2017","journal-title":"Med. Eng. Phys."},{"key":"2025092513265535000_c12","doi-asserted-by":"publisher","first-page":"2824","DOI":"10.1016\/j.jbiomech.2016.06.024","article-title":"A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation","volume":"49","year":"2016","journal-title":"J. Biomech."},{"key":"2025092513265535000_c13","doi-asserted-by":"publisher","first-page":"107727","DOI":"10.1016\/j.cmpb.2023.107727","article-title":"Credibility assessment of computational models according to ASME V&V40: Application to the Bologna Biomechanical Computed Tomography solution","volume":"240","year":"2023","journal-title":"Comput. Methods Programs Biomed."},{"key":"2025092513265535000_c14","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1007\/s10439-022-03078-w","article-title":"A credibility assessment plan for an in silico model that predicts the dose-response relationship of new tuberculosis treatments","volume":"51","year":"2023","journal-title":"Ann. Biomed. Eng."},{"key":"2025092513265535000_c15","doi-asserted-by":"publisher","first-page":"e1010541","DOI":"10.1371\/journal.pcbi.1010541","article-title":"Credibility assessment of patient-specific computational modeling using patient-specific cardiac modeling as an exemplar","volume":"18","year":"2022","journal-title":"PLoS Comput. Biol."},{"key":"2025092513265535000_c16","doi-asserted-by":"publisher","first-page":"e1010141","DOI":"10.1371\/journal.pcbi.1010141","article-title":"Design and execution of a verification, validation, and uncertainty quantification plan for a numerical model of left ventricular flow after LVAD implantation","volume":"18","year":"2022","journal-title":"PLoS Comput. Biol."},{"key":"2025092513265535000_c17","doi-asserted-by":"publisher","first-page":"111423","DOI":"10.1016\/j.jbiomech.2022.111423","article-title":"Applicability assessment for in-silico patient-specific TEVAR procedures","volume":"146","year":"2023","journal-title":"J. Biomech."},{"key":"2025092513265535000_c18","doi-asserted-by":"publisher","first-page":"112357","DOI":"10.1016\/j.jbiomech.2024.112357","article-title":"On the accuracy of the segmentation process and transcatheter heart valve dimensions in TAVI patients","volume":"176","year":"2024","journal-title":"J. Biomech."},{"key":"2025092513265535000_c19","first-page":"311","article-title":"Establishing in-silico credibility of patient-specific finite-element model in a virtual cohort","volume":"39","year":"2024","journal-title":"L N Comput. Vis. Biome"},{"key":"2025092513265535000_c20","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","article-title":"Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations","volume":"71","year":"2018","journal-title":"J. Biomech."},{"key":"2025092513265535000_c21","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1080\/10255842.2015.1058928","article-title":"Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root","volume":"19","year":"2016","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"2025092513265535000_c22","first-page":"1","article-title":"Development and credibility assessment of a TAVI heart-valve FSI-model","year":"2024"},{"key":"2025092513265535000_c23","doi-asserted-by":"publisher","first-page":"815","DOI":"10.1007\/s11517-020-02138-4","article-title":"Simulation study of transcatheter heart valve implantation in patients with stenotic bicuspid aortic valve","volume":"58","year":"2020","journal-title":"Med. Biol. Eng. Comput."}],"updated-by":[{"DOI":"10.1063\/5.0335660","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2026,4,22]],"date-time":"2026-04-22T00:00:00Z","timestamp":1776816000000}}],"container-title":["APL Bioengineering"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0280958\/20715838\/046101_1_5.0280958.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/apb\/article-pdf\/doi\/10.1063\/5.0280958\/20715838\/046101_1_5.0280958.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,25]],"date-time":"2025-09-25T17:27:06Z","timestamp":1758821226000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/apb\/article\/9\/4\/046101\/3364723\/Credibility-assessment-of-patient-specific"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,25]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2025,12,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0280958","relation":{},"ISSN":["2473-2877"],"issn-type":[{"value":"2473-2877","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2025,12,1]]},"published":{"date-parts":[[2025,9,25]]},"article-number":"046101"}}