{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T13:10:23Z","timestamp":1783948223985,"version":"3.55.0"},"reference-count":65,"publisher":"AIP Publishing","issue":"7","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7,1]]},"abstract":"<jats:p>We present the design, calibration, qualification, and application of a fast and compact scatterometer designed for the characterization of ex vivo human corneas. As an alternative to standard qualification processes and in order to meet the current need for improved reliability of graft qualification, this instrument provides a non-invasive, label-free, and contact-free quantitative means of characterizing corneal grafts, based on back-scattered light diffusometry. The instrument is shown to be capable of detecting BRDF (bidirectional reflectance distribution function) variations of 1.4 \u00d7 10\u22124 sr\u22121 with a detectivity threshold of 2.0 \u00d7 10\u22123 sr\u22121, with an overall dynamics &amp;gt;27 dB for the total integrated scattering parameter used for graft quality assessment. We also demonstrate the feasibility of integrating this new technique into tissue bank qualification processes through controlled test experiments reported here.<\/jats:p>","DOI":"10.1063\/5.0327390","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T12:36:13Z","timestamp":1783946173000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":0,"title":["Fast and compact scatterometer for ex vivo qualification of low-scattering biological samples"],"prefix":"10.1063","volume":"97","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-5423-1776","authenticated-orcid":false,"given":"A.","family":"Sarrade","sequence":"first","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]},{"name":"Ramsay G\u00e9n\u00e9rale de Sant\u00e9, Clinique Monticelli-Velodrome 2 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0008-1158-7675","authenticated-orcid":false,"given":"J.","family":"El Allam","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Espinas","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]},{"name":"Centre Europ\u00e9en de Recherche en Imagerie M\u00e9dicale (CERIMED), Aix-Marseille University, CNRS 3 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4798-0555","authenticated-orcid":false,"given":"L.","family":"Hoffart","sequence":"additional","affiliation":[{"name":"Ramsay G\u00e9n\u00e9rale de Sant\u00e9, Clinique Monticelli-Velodrome 2 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9118-5239","authenticated-orcid":false,"given":"C.","family":"Picard","sequence":"additional","affiliation":[{"name":"Tissue Bank, French Blood Establishment 4 , Marseille,","place":["France"]},{"name":"ADES, French Blood Establishment\/Aix-Marseille University\/CNRS 5 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7192-1523","authenticated-orcid":false,"given":"T.","family":"David","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Georges","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Deumi\u00e9","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]},{"name":"Centre Europ\u00e9en de Recherche en Imagerie M\u00e9dicale (CERIMED), Aix-Marseille University, CNRS 3 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-4813-781X","authenticated-orcid":false,"given":"L.","family":"Siozade Lamoine","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]},{"name":"Centre Europ\u00e9en de Recherche en Imagerie M\u00e9dicale (CERIMED), Aix-Marseille University, CNRS 3 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3371-8775","authenticated-orcid":false,"given":"J.","family":"Fade","sequence":"additional","affiliation":[{"name":"Aix Marseille Univ, CNRS, Centrale Med, Institut Fresnel 1 , Marseille,","place":["France"]},{"name":"Centre Europ\u00e9en de Recherche en Imagerie M\u00e9dicale (CERIMED), Aix-Marseille University, CNRS 3 , Marseille,","place":["France"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2026,7,13]]},"reference":[{"issue":"9","key":"2026071308360502800_c1","doi-asserted-by":"publisher","first-page":"3142","DOI":"10.4103\/ijo.ijo_1942_23","article-title":"Corneal blindness and eye banking: Current strategies and best practices","volume":"71","year":"2023","journal-title":"Indian J. Ophthalmol."},{"issue":"9","key":"2026071308360502800_c2","doi-asserted-by":"publisher","first-page":"1078","DOI":"10.1111\/ceo.13978","article-title":"Corneal supply and the use of technology to reduce its demand: A review","volume":"49","year":"2021","journal-title":"Clin. Exp. Ophthalmol."},{"issue":"8","key":"2026071308360502800_c3","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1016\/j.ophtha.2023.03.012","article-title":"Global trends in blindness and vision impairment resulting from corneal opacity 1984\u20132020: A meta-analysis","volume":"130","year":"2023","journal-title":"Ophthalmology"},{"issue":"3","key":"2026071308360502800_c4","doi-asserted-by":"publisher","first-page":"465","DOI":"10.1016\/j.survophthal.2023.12.002","article-title":"Quality assurance in corneal transplants: Donor cornea assessment and oversight","volume":"69","year":"2024","journal-title":"Surv. Ophthalmol."},{"key":"2026071308360502800_c5","first-page":"2963","volume-title":"Corneal Donation: Current Guidelines and Future Direction","year":"2021"},{"issue":"10","key":"2026071308360502800_c6","doi-asserted-by":"publisher","first-page":"e30097","DOI":"10.7759\/cureus.30097","article-title":"A review of corneal blindness: Causes and management","volume":"14","year":"2022","journal-title":"Cureus"},{"issue":"2","key":"2026071308360502800_c7","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1001\/jamaophthalmol.2015.4776","article-title":"Global survey of corneal transplantation and eye banking","volume":"134","year":"2016","journal-title":"JAMA Ophthalmol."},{"issue":"2","key":"2026071308360502800_c8","doi-asserted-by":"publisher","first-page":"e1434","DOI":"10.1097\/txd.0000000000001434","article-title":"Overview of corneal transplantation for the nonophthalmologist","volume":"9","year":"2023","journal-title":"Transplant. Direct"},{"key":"2026071308360502800_c9","doi-asserted-by":"publisher","first-page":"23","DOI":"10.2147\/bsam.s114197","article-title":"The structure and evolution of eye banking: A review on eye banks\u2019 historical, present, and future contribution to corneal transplantation","volume":"5","year":"2017","journal-title":"J.\u00a0Biorepos. Sci. Appl. Med."},{"issue":"5","key":"2026071308360502800_c10","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1007\/s10792-021-01736-x","article-title":"Donor demographics and factors affecting corneal utilisation in eye bank of North India","volume":"41","year":"2021","journal-title":"Int. Ophthalmol."},{"issue":"5","key":"2026071308360502800_c11","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1136\/bjo-2022-323162","article-title":"Descemet\u2019s membrane endothelial keratoplasty is the predominant keratoplasty procedure in Germany since 2016: A report of the dog-section cornea and its keratoplasty registry","volume":"108","year":"2024","journal-title":"Br. J. Ophthalmol."},{"key":"2026071308360502800_c12","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1159\/000223835","article-title":"European eye bank association","volume":"43","year":"2009","journal-title":"Eye Bank."},{"key":"2026071308360502800_c13"},{"issue":"8","key":"2026071308360502800_c14","doi-asserted-by":"publisher","first-page":"e1077","DOI":"10.1111\/aos.14185","article-title":"Significant differences between specular microscopy and corneal bank endothelial cell counts \u2013 a pilot study","volume":"97","year":"2019","journal-title":"Acta Ophthalmol."},{"issue":"1","key":"2026071308360502800_c15","first-page":"3","article-title":"Assessment of corneal quality by eye banks","volume":"6","year":"2011","journal-title":"J.\u00a0Ophthalmic Vision Res."},{"issue":"2","key":"2026071308360502800_c16","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1111\/aos.13108","article-title":"The role of corneal endothelial morphology in graft assessment and prediction of endothelial cell loss during organ culture of human donor corneas","volume":"95","year":"2017","journal-title":"Acta Ophthalmol."},{"issue":"8","key":"2026071308360502800_c17","doi-asserted-by":"publisher","first-page":"6018","DOI":"10.1167\/iovs.10-6641","article-title":"Pan-corneal endothelial viability assessment: Application to endothelial grafts predissected by eye banks","volume":"52","year":"2011","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"2026071308360502800_c18","unstructured":"S.\n            Laverne-Acquart\n          , \u201cBanque de corn\u00e9e: 10 ans d\u2019innovations en contr\u00f4le qualit\u00e9 du greffon corn\u00e9en et projets d\u2019avenir,\u201d Ph.D. thesis, Universit\u00e9 Jean Monnet-Saint-Etienne, 2013."},{"issue":"1","key":"2026071308360502800_c19","doi-asserted-by":"publisher","first-page":"e002","DOI":"10.1097\/ebct.0000000000000002","article-title":"Eye bank association of America medical standards 2022","volume":"1","author":"Eye Bank Association of America","year":"2022","journal-title":"Eye Bank. Corneal Transplant."},{"issue":"1","key":"2026071308360502800_c20","doi-asserted-by":"publisher","first-page":"e002399","DOI":"10.1136\/bmjophth-2025-002399","article-title":"Clinical and epidemiological factors affecting donor corneal endothelial cell density","volume":"10","year":"2025","journal-title":"BMJ Open Ophthalmol."},{"issue":"4","key":"2026071308360502800_c21","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1136\/bjo.82.4.382","article-title":"Donor organ cultured corneal tissue selection before penetrating keratoplasty","volume":"82","year":"1998","journal-title":"Br. J. Ophthalmol."},{"issue":"2","key":"2026071308360502800_c22","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.ajo.2004.09.045","article-title":"Corneal endothelium and postoperative outcomes 15 years after penetrating keratoplasty","volume":"139","year":"2005","journal-title":"Am. J. Ophthalmol."},{"issue":"2","key":"2026071308360502800_c23","doi-asserted-by":"publisher","first-page":"129","DOI":"10.3892\/etm.2021.11052","article-title":"Risk factors for fluctuations in corneal endothelial cell density (Review)","volume":"23","year":"2022","journal-title":"Exp. Ther. Med."},{"issue":"8","key":"2026071308360502800_c24","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1016\/j.ophtha.2022.03.015","article-title":"Corneal endothelial cell density loss after glaucoma surgery alone or in combination with cataract surgery: A systematic review and meta-analysis","volume":"129","year":"2022","journal-title":"Ophthalmology"},{"key":"2026071308360502800_c25","doi-asserted-by":"publisher","first-page":"100082","DOI":"10.1016\/j.rio.2021.100082","article-title":"Non invasive backscattering light to detection of endothelial cells activity for graft sorting: Proof of consent","volume":"4","year":"2021","journal-title":"Results Opt."},{"issue":"4","key":"2026071308360502800_c26","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1038\/s41433-024-02969-7","article-title":"Structural control of corneal transparency, refractive power and dynamics","volume":"39","year":"2025","journal-title":"Eye"},{"issue":"1","key":"2026071308360502800_c27","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1167\/iovs.63.1.22","article-title":"Corneal opacity: Cell biological determinants of the transition from transparency to transient haze to scarring fibrosis, and resolution, after injury","volume":"63","year":"2022","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"issue":"1","key":"2026071308360502800_c28","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1186\/s13287-021-02611-3","article-title":"Ex vivo expansion and characterization of human corneal endothelium for transplantation: A review","volume":"12","year":"2021","journal-title":"Stem Cell Res. Ther."},{"issue":"1","key":"2026071308360502800_c29","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1113\/jphysiol.1972.sp009736","article-title":"The metabolic basis to the fluid pump in the cornea","volume":"221","year":"1972","journal-title":"J.\u00a0Physiol."},{"issue":"3","key":"2026071308360502800_c30","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1016\/0022-5193(71)90090-7","article-title":"Why the cornea swells","volume":"33","year":"1971","journal-title":"J.\u00a0Theor. Biol."},{"issue":"4","key":"2026071308360502800_c31","doi-asserted-by":"publisher","first-page":"17","DOI":"10.9734\/or\/2020\/v12i430152","article-title":"Corneal endothelium an important layer for corneal transparency and its assessment \u2013 a review","volume":"12","year":"2020","journal-title":"Ophthalmol. Res. Int. J."},{"issue":"2","key":"2026071308360502800_c32","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1097\/ico.0000000000002511","article-title":"Age-related corneal transparency changes evaluated with an alternative method to corneal densitometry","volume":"40","year":"2021","journal-title":"Cornea"},{"issue":"1","key":"2026071308360502800_c33","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1111\/opo.13067","article-title":"Corneal tissue changes following short-term soft contact lens wear of different materials","volume":"43","year":"2023","journal-title":"Ophthal. Physiol. Opt."},{"key":"2026071308360502800_c34","doi-asserted-by":"publisher","first-page":"1144455","DOI":"10.3389\/fbioe.2023.1144455","article-title":"Corneal optical density: Structural basis, measurements, influencing factors, and roles in refractive surgery","volume":"11","year":"2023","journal-title":"Front. Bioeng. Biotechnol."},{"issue":"1","key":"2026071308360502800_c35","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1186\/s12886-018-0998-5","article-title":"Quantitative evaluation of corneal epithelial edema after cataract surgery using corneal densitometry: A prospective study","volume":"18","year":"2018","journal-title":"BMC Ophthalmol."},{"issue":"7","key":"2026071308360502800_c36","doi-asserted-by":"publisher","first-page":"1210","DOI":"10.1016\/j.jcrs.2009.03.017","article-title":"Repeatability and validity of lens densitometry measured with scheimpflug imaging","volume":"35","year":"2009","journal-title":"J.\u00a0Cataract Refractive Surg."},{"issue":"1","key":"2026071308360502800_c37","doi-asserted-by":"publisher","first-page":"016001","DOI":"10.1117\/1.jbo.22.1.016001","article-title":"Optical coherence tomography-based topography determination of corneal grafts in eye bank cultivation","volume":"22","year":"2017","journal-title":"J.\u00a0Biomed. Opt."},{"issue":"10","key":"2026071308360502800_c38","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1097\/ico.0000000000001700","article-title":"Characterization of corneal donor tissue lesions by anterior segment optical coherence tomography compared with eye bank technician slit-lamp examination","volume":"37","year":"2018","journal-title":"Cornea"},{"issue":"4","key":"2026071308360502800_c39","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1097\/ico.0b013e3181f236c6","article-title":"Comparison of central corneal graft thickness to visual acuity outcomes in endothelial keratoplasty","volume":"30","year":"2011","journal-title":"Cornea"},{"issue":"4","key":"2026071308360502800_c40","doi-asserted-by":"publisher","first-page":"580","DOI":"10.1136\/bjo.2010.190595","article-title":"Evaluation of a new method for the measurement of corneal thickness in eye bank posterior corneal lenticules using anterior segment optical coherence tomography","volume":"95","year":"2011","journal-title":"Br. J. Ophthalmol."},{"issue":"4","key":"2026071308360502800_c41","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1007\/s10561-021-09980-2","article-title":"Reliability and efficiency of corneal thickness measurements using sterile donor tomography in the eye bank","volume":"23","year":"2022","journal-title":"Cell Tissue Banking"},{"key":"2026071308360502800_c42","unstructured":"R.\n            Bocheux\n          , \u201cCaract\u00e9risation objective et quantitative de la transparence corn\u00e9enne par OCT plein champ et microscopie holographique,\u201d Ph.D. thesis, Universit\u00e9 Paris Saclay (COmUE), 2019."},{"issue":"8","key":"2026071308360502800_c43","doi-asserted-by":"publisher","first-page":"e0221707","DOI":"10.1371\/journal.pone.0221707","article-title":"Quantitative measures of corneal transparency, derived from objective analysis of depth-resolved corneal images, demonstrated with full-field optical coherence tomographic microscopy","volume":"14","year":"2019","journal-title":"PLoS One"},{"issue":"10","key":"2026071308360502800_c44","doi-asserted-by":"publisher","first-page":"e0291613","DOI":"10.1371\/journal.pone.0291613","article-title":"A new method for in vivo assessment of corneal transparency using spectral-domain oct","volume":"18","year":"2023","journal-title":"PLoS One"},{"issue":"3","key":"2026071308360502800_c45","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/j.ophtha.2004.10.045","article-title":"An evaluation of image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in the specular microscopy ancillary study","volume":"112","year":"2005","journal-title":"Ophthalmology"},{"issue":"4","key":"2026071308360502800_c46","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.clae.2004.08.001","article-title":"Grading of corneal transparency","volume":"27","year":"2004","journal-title":"Contact Lens Anterior Eye"},{"issue":"08","key":"2026071308360502800_c47","doi-asserted-by":"publisher","first-page":"085001","DOI":"10.1117\/1.jbo.24.8.085001","article-title":"Quantitative assessment of human donor corneal endothelium with Gabor domain optical coherence microscopy","volume":"24","year":"2019","journal-title":"J.\u00a0Biomed. Opt."},{"issue":"09","key":"2026071308360502800_c48","doi-asserted-by":"publisher","first-page":"092902","DOI":"10.1117\/1.jbo.25.9.092902","article-title":"Unbiased corneal tissue analysis using Gabor-domain optical coherence microscopy and machine learning for automatic segmentation of corneal endothelial cells","volume":"25","year":"2020","journal-title":"J.\u00a0Biomed. Opt."},{"issue":"7","key":"2026071308360502800_c49","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/ico.0b013e3181705ca2","article-title":"An easy and inexpensive method for quantitative analysis of endothelial damage by using vital dye staining and adobe photoshop software","volume":"27","year":"2008","journal-title":"Cornea"},{"issue":"4","key":"2026071308360502800_c50","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1080\/02713680500536738","article-title":"Specular microscopy ancillary study methods for donor endothelial cell density determination of cornea donor study images","volume":"31","year":"2006","journal-title":"Curr. Eye Res."},{"issue":"06","key":"2026071308360502800_c51","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1055\/s-2008-1034821","article-title":"Wissensbasierte bildanalyse des endothels von hornhauttr-ansplantaten","volume":"214","year":"1999","journal-title":"Klin. Monbl. Augenheilkd."},{"issue":"1","key":"2026071308360502800_c52","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1186\/1475-925x-4-70","article-title":"Portable light transmission measuring system for preserved corneas","volume":"4","year":"2005","journal-title":"Biomed. Eng. Online"},{"issue":"3","key":"2026071308360502800_c53","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s10561-013-9414-9","article-title":"Non-invasive measurement of transparency, arcus senilis, and scleral rim diameter of corneas during eye banking","volume":"15","year":"2014","journal-title":"Cell Tissue Bank."},{"key":"2026071308360502800_c54","doi-asserted-by":"publisher","first-page":"S55","DOI":"10.1097\/ico.0000000000000994","article-title":"Evaluation of visual quality in patients with Fuchs endothelial corneal dystrophy","volume":"35","year":"2016","journal-title":"Cornea"},{"issue":"3","key":"2026071308360502800_c55","doi-asserted-by":"publisher","first-page":"1356","DOI":"10.1167\/iovs.08-3103","article-title":"Endothelial morphometry by image analysis of corneas organ cultured at 31 \u00b0C","volume":"51","year":"2010","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"2026071308360502800_c56","unstructured":"G.\n            Pataia\n          , \u201cConception et d\u00e9veloppement d\u2019instruments de caract\u00e9risation optique pour le contr\u00f4le qualit\u00e9 cellulaire et tissulaire de greffons corn\u00e9ens conserv\u00e9s en bior\u00e9acteur,\u201d Ph.D. thesis, Saint-Etienne, 2015."},{"issue":"10","key":"2026071308360502800_c57","doi-asserted-by":"publisher","first-page":"786","DOI":"10.3928\/1081597x-20100921-04","article-title":"Effect of incident light wavelength and corneal edema on light scattering and penetration: Laboratory study of human corneas","volume":"26","year":"2010","journal-title":"J.\u00a0Refractive Surg."},{"issue":"5","key":"2026071308360502800_c58","doi-asserted-by":"publisher","first-page":"053104","DOI":"10.1063\/1.3452334","article-title":"Light scattering from human corneal grafts: Bulk and surface contribution","volume":"108","year":"2010","journal-title":"J.\u00a0Appl. Phys."},{"issue":"4","key":"2026071308360502800_c59","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1038\/eye.1990.81","article-title":"Light scatter from the central human cornea","volume":"4","year":"1990","journal-title":"Eye"},{"issue":"8","key":"2026071308360502800_c60","doi-asserted-by":"publisher","first-page":"1793","DOI":"10.1364\/boe.3.001793","article-title":"Light scattering from edematous human corneal grafts\u2019 microstructure: Experimental study and electromagnetic modelization","volume":"3","year":"2012","journal-title":"Biomed. Opt. Express"},{"issue":"3","key":"2026071308360502800_c61","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1113\/jphysiol.1973.sp010325","article-title":"Wave-length dependencies of light scattering in normal and cold swollen rabbit corneas and their structural implications","volume":"233","year":"1973","journal-title":"J.\u00a0Physiol."},{"issue":"4","key":"2026071308360502800_c62","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1111\/opo.13126","article-title":"Forward-scattered and backward-scattered light in moderate keratoconus","volume":"43","year":"2023","journal-title":"Ophthal. Physiol. Opt."},{"key":"2026071308360502800_c63","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.optcom.2018.11.006","article-title":"Detection of fine modifications in bulk corneal grafts based on backscattered light quantification","volume":"434","year":"2019","journal-title":"Opt. Commun."},{"key":"2026071308360502800_c64","article-title":"Towards an objective assessment of corneal grafts quality using back-scattered light measurements"},{"issue":"12","key":"2026071308360502800_c65","doi-asserted-by":"publisher","first-page":"2141","DOI":"10.1080\/00949655.2010.520163","article-title":"Comparisons of various types of normality tests","volume":"81","year":"2011","journal-title":"J.\u00a0Stat. Comput. Simul."}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0327390\/21072385\/074101_1_5.0327390.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0327390\/21072385\/074101_1_5.0327390.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T12:36:14Z","timestamp":1783946174000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/97\/7\/074101\/3398203\/Fast-and-compact-scatterometer-for-ex-vivo"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,1]]},"references-count":65,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0327390","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,7]]},"published":{"date-parts":[[2026,7,1]]},"article-number":"074101"}}