{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T13:01:26Z","timestamp":1791464486187,"version":"4.3.4"},"reference-count":45,"publisher":"AIP Publishing","issue":"10","funder":[{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","award":["DE-SC0019004"],"award-info":[{"award-number":["DE-SC0019004"]}],"id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","award":["DE-SC0021140"],"award-info":[{"award-number":["DE-SC0021140"]}],"id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","award":["DE-FC02-04ER54698"],"award-info":[{"award-number":["DE-FC02-04ER54698"]}],"id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000015","name":"U.S. Department of Energy","doi-asserted-by":"publisher","award":["and DE-FG02-08ER54999"],"award-info":[{"award-number":["and DE-FG02-08ER54999"]}],"id":[{"id":"10.13039\/100000015","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:p>Future fusion reactors require robust monitoring of plasma equilibrium and fluctuations to sustain and optimize energy gain, despite severely restricted machine access. We demonstrate a multifunctional interferometer-polarimeter on the DIII-D tokamak that utilizes only four radial chords to simultaneously measure: (a) the interferometric phase shift, (b) the Faraday effect, (c) the Cotton\u2013Mouton effect, (d) density and magnetic fluctuations up to 10\u00a0MHz, and (e) fluctuation toroidal mode numbers and vertical wavenumbers. This is achieved via a three-wave, dual-sensor scheme incorporating four vertically and toroidally displaced chords. The Faraday effect measurements constrain the core magnetic equilibrium, directly determining the magnetic axis vertical position. The Cotton\u2013Mouton effect measurement yields a robust line-integrated density measurement free of fringe jumps. Furthermore, fluctuation and wavenumber measurements enable mode localization, facilitating a spatiotemporal survey of multiscale fluctuations from the plasma core to the edge. These results validate a compact interferometry-polarimetry approach capable of delivering comprehensive equilibrium and fluctuation measurements under limited access, supporting the demands of fusion reactors.<\/jats:p>","DOI":"10.1063\/5.0347643","type":"journal-article","created":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T12:39:05Z","timestamp":1791463145000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":0,"title":["Multifunctional interferometry-polarimetry for fusion plasma control and physics applications (invited)"],"prefix":"10.1063","volume":"97","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4853-5341","authenticated-orcid":false,"given":"J.","family":"Chen","sequence":"first","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9153-6702","authenticated-orcid":false,"given":"D. L.","family":"Brower","sequence":"additional","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9888-5545","authenticated-orcid":false,"given":"T.","family":"Benedett","sequence":"additional","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8156-6230","authenticated-orcid":false,"given":"G.","family":"Prabhudesai","sequence":"additional","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5224-1234","authenticated-orcid":false,"given":"M.","family":"Poulos","sequence":"additional","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0403-1264","authenticated-orcid":false,"given":"W.","family":"Ding","sequence":"additional","affiliation":[{"name":"University of California, Los Angeles 1 , Los Angeles, California 90095,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Finkenthal","sequence":"additional","affiliation":[{"name":"Palomar Scientific Instruments 2 , San Marcos, California 92069,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6004-2005","authenticated-orcid":false,"given":"F.","family":"Khabanov","sequence":"additional","affiliation":[{"name":"University of Wisconsin-Madison 3 , Madison, Wisconsin 53706,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suk-Ho","family":"Hong","sequence":"additional","affiliation":[{"name":"General Atomics 4 , San Diego, California 92121,","place":["USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"317","published-online":{"date-parts":[[2026,10,8]]},"reference":[{"key":"2026100808385949500_c1","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/0020-0891(78)90102-1","article-title":"A far-infrared \u2018polari-interferometer\u2019 for simultaneous electron density and magnetic field measurements in plasmas","volume":"18","year":"1978","journal-title":"Infrared Phys."},{"key":"2026100808385949500_c2","doi-asserted-by":"publisher","first-page":"3407","DOI":"10.1063\/1.1145516","article-title":"High spatial resolution interferometry and polarimetry in hot plasmas","volume":"66","year":"1995","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c3","doi-asserted-by":"publisher","first-page":"2825","DOI":"10.1063\/1.1140666","article-title":"JET polari-interferometer","volume":"60","year":"1989","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c4","doi-asserted-by":"publisher","first-page":"10F324","DOI":"10.1063\/1.2229169","article-title":"Simultaneous Cotton-Mouton and Faraday rotation angle measurements on JET","volume":"77","year":"2006","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c5","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1088\/0741-3335\/39\/4\/006","article-title":"Poloidal magnetic field measurements on TEXT-Upgrade","volume":"39","year":"1997","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c6","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1063\/1.1149364","article-title":"Far infrared tangential interferometry\/polarimetry on the National Spherical Tokamak Experiment","volume":"70","year":"1999","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c7","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1063\/1.1321744","article-title":"Multichannel far-infrared polarimeter-interferometer system on the MST reversed field pinch","volume":"72","year":"2001","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c8","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.1063\/1.1526927","article-title":"Laser polarimetric measurement of equilibrium and fluctuating magnetic fields in a reversed field pinch (invited)","volume":"74","year":"2003","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c9","doi-asserted-by":"publisher","first-page":"10F108","DOI":"10.1063\/1.2222332","article-title":"High-speed three-wave polarimeter-interferometer diagnostic for Madison symmetric torus","volume":"77","year":"2006","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c10","doi-asserted-by":"publisher","first-page":"11D303","DOI":"10.1063\/1.4891603","article-title":"High resolution polarimeter-interferometer system for fast equilibrium dynamics and MHD instability studies on joint-TEXT tokamak (invited)","volume":"85","year":"2014","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c11","doi-asserted-by":"publisher","first-page":"11D903","DOI":"10.1063\/1.4963378","article-title":"Initial measurements of plasma current and electron density profiles using a polarimeter\/interferometer (POINT) for long pulse operation in EAST (invited)","volume":"87","year":"2016","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c12","doi-asserted-by":"publisher","first-page":"11E108","DOI":"10.1063\/1.4960056","article-title":"Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D","volume":"87","year":"2016","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c13","doi-asserted-by":"publisher","first-page":"10E336","DOI":"10.1063\/1.4739226","article-title":"Multi-channel far-infrared HL-2A interferometer-polarimeter","volume":"83","year":"2012","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c14","doi-asserted-by":"publisher","first-page":"045006","DOI":"10.1088\/1361-6587\/ae5338","article-title":"Development of the FIR laser polarimeter\/interferometer on HL-3 tokamak","volume":"68","year":"2026","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c15","doi-asserted-by":"publisher","first-page":"053516","DOI":"10.1063\/5.0043882","article-title":"Development of Faraday rotation measurements on Keda Reconnection eXperiment (KRX) device","volume":"92","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c16","doi-asserted-by":"publisher","first-page":"11E114","DOI":"10.1063\/1.4960415","article-title":"Far-infrared tangential interferometer\/polarimeter design and installation for NSTX-U","volume":"87","year":"2016","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c17","doi-asserted-by":"publisher","first-page":"083511","DOI":"10.1063\/5.0217322","article-title":"Design of radial interferometer\u2013polarimeter for internal magnetic and density fluctuation measurements at multiple space\u2013time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)","volume":"95","year":"2024","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c18","doi-asserted-by":"publisher","first-page":"045027","DOI":"10.1088\/1361-6587\/ae56b9","article-title":"Development and validation of a ray-tracing-based polarimeter\u2013interferometer model for density and Faraday rotation prediction","volume":"68","year":"2026","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c19","doi-asserted-by":"publisher","first-page":"C06061","DOI":"10.1088\/1748-0221\/20\/06\/c06061","article-title":"DTT interferometer and polarimeter systems","volume":"20","year":"2025","journal-title":"J.\u00a0Instrum."},{"key":"2026100808385949500_c20","doi-asserted-by":"publisher","first-page":"10B102","DOI":"10.1063\/1.5037461","article-title":"Tests of a full-scale ITER toroidal interferometer and polarimeter (TIP) prototype on the DIII-D tokamak (invited)","volume":"89","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c21","doi-asserted-by":"publisher","first-page":"C03001","DOI":"10.1088\/1748-0221\/20\/03\/c03001","article-title":"ITER density interferometer polarimeter: Theoretical estimation of temperature, pressure and humidity variation effect on phase measurement and correction strategy","volume":"20","year":"2025","journal-title":"J.\u00a0Instrum."},{"key":"2026100808385949500_c22","doi-asserted-by":"publisher","first-page":"C04001","DOI":"10.1088\/1748-0221\/17\/04\/c04001","article-title":"Design considerations of the European DEMO\u2019s IR-interferometer\/polarimeter based on TRAVIS simulations","volume":"17","year":"2022","journal-title":"J.\u00a0Inst."},{"key":"2026100808385949500_c23","doi-asserted-by":"publisher","first-page":"115638","DOI":"10.1016\/j.fusengdes.2026.115638","article-title":"Consideration of density measurement using toroidal interferometer and polarimeter on JA DEMO","volume":"225","year":"2026","journal-title":"Fusion Eng. Des."},{"key":"2026100808385949500_c24","doi-asserted-by":"publisher","first-page":"042516","DOI":"10.1063\/1.5142638","article-title":"Design study of a combined interferometer and polarimeter for a high-field, compact tokamak","volume":"27","year":"2020","journal-title":"Phys. Plasmas"},{"key":"2026100808385949500_c25","doi-asserted-by":"publisher","first-page":"R57","DOI":"10.1088\/0741-3335\/41\/2\/001","article-title":"A review of plasma polarimetry\u2014Theory and methods","volume":"41","year":"1999","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c26","doi-asserted-by":"publisher","first-page":"043502","DOI":"10.1063\/5.0040306","article-title":"Correlation polarimeter-interferometer in the DIII-D tokamak","volume":"92","year":"2021","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c27","doi-asserted-by":"publisher","first-page":"022506","DOI":"10.1063\/5.0039154","article-title":"Pedestal magnetic turbulence measurements in ELMy H-mode DIII-D plasmas by Faraday-effect polarimetry","volume":"28","year":"2021","journal-title":"Phys. Plasmas"},{"key":"2026100808385949500_c28","doi-asserted-by":"publisher","first-page":"086054","DOI":"10.1088\/1741-4326\/ad5aae","article-title":"Turbulence link to L-mode, I-mode, and H-mode confinement in the DIII-D tokamak","volume":"64","year":"2024","journal-title":"Nucl. Fusion"},{"key":"2026100808385949500_c29","doi-asserted-by":"publisher","first-page":"013507","DOI":"10.1063\/5.0129892","article-title":"Implementing Faraday effect measurement constraints into the Grad\u2013Shafranov equilibrium fitting code EFIT","volume":"94","year":"2023","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c30","doi-asserted-by":"publisher","first-page":"056016","DOI":"10.1088\/1741-4326\/ae5837","article-title":"Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements","volume":"66","year":"2026","journal-title":"Nucl. Fusion"},{"key":"2026100808385949500_c31","volume-title":"Ideal MHD","year":"2014"},{"key":"2026100808385949500_c32","doi-asserted-by":"publisher","first-page":"093522","DOI":"10.1063\/5.0217020","article-title":"Upgrade of DIII-D radial interferometer\u2013polarimeter for large bandwidth, low noise, and toroidal mode number measurements","volume":"95","year":"2024","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c33","doi-asserted-by":"publisher","first-page":"10B106","DOI":"10.1063\/1.5035413","article-title":"A combined phase contrast imaging and heterodyne interferometer system for multiscale fluctuation measurements (invited)","volume":"89","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c34","doi-asserted-by":"publisher","first-page":"10B101","DOI":"10.1063\/1.5035276","article-title":"A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D","volume":"89","year":"2018","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c35","doi-asserted-by":"publisher","first-page":"085001","DOI":"10.1088\/1361-6587\/aac708","article-title":"Impact of the Cotton\u2013Mouton effect on Faraday polarimetry measurements using circular polarization","volume":"60","year":"2018","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c36","doi-asserted-by":"publisher","first-page":"113022","DOI":"10.1088\/0029-5515\/51\/11\/113022","article-title":"A new approach of equilibrium reconstruction for ITER","volume":"51","year":"2011","journal-title":"Nucl. Fusion"},{"key":"2026100808385949500_c37","doi-asserted-by":"publisher","first-page":"113001","DOI":"10.1088\/1741-4326\/adfc7c","article-title":"Diagnostics: Chapter 8 of the special issue: On the path to tokamak burning plasma operation","volume":"65","year":"2025","journal-title":"Nucl. Fusion"},{"key":"2026100808385949500_c38","doi-asserted-by":"publisher","first-page":"085009","DOI":"10.1088\/1361-6587\/ad5a3a","article-title":"Core inductive electric field during sawtooth crashes on DIII-D","volume":"66","year":"2024","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2026100808385949500_c39","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.1038\/s41586-024-07545-3","article-title":"A high-density and high-confinement tokamak plasma regime for fusion energy","volume":"630","year":"2024","journal-title":"Nature"},{"key":"2026100808385949500_c40","doi-asserted-by":"publisher","first-page":"023502","DOI":"10.1063\/1.2166493","article-title":"Magnetic diagnostic system of the DIII-D tokamak","volume":"77","year":"2006","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c41","doi-asserted-by":"publisher","first-page":"2014","DOI":"10.1063\/1.1535248","article-title":"Turbulence imaging and applications using beam emission spectroscopy on DIII-D (invited)","volume":"74","year":"2003","journal-title":"Rev. Sci. Instrum."},{"key":"2026100808385949500_c42","doi-asserted-by":"publisher","first-page":"145101","DOI":"10.1103\/physrevlett.131.145101","article-title":"Experimental validation of a kinetic ballooning mode in high-performance high-bootstrap current fraction fusion plasmas","volume":"131","year":"2023","journal-title":"Phys. Rev. Lett."},{"key":"2026100808385949500_c43","doi-asserted-by":"publisher","first-page":"106016","DOI":"10.1088\/1741-4326\/ac84f0","article-title":"Application of simulations and theory of sub-cyclotron frequency modes to DIII-D","volume":"62","year":"2022","journal-title":"Nucl. Fusion"},{"key":"2026100808385949500_c44","first-page":"566","volume-title":"Waves in Plasmas","year":"1992","edition":"1"},{"key":"2026100808385949500_c45"}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0347643\/21165697\/103516_1_5.0347643.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/5.0347643\/21165697\/103516_1_5.0347643.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T12:39:06Z","timestamp":1791463146000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/97\/10\/103516\/3406192\/Multifunctional-interferometry-polarimetry-for"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":45,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10,1]]}},"URL":"https:\/\/doi.org\/10.1063\/5.0347643","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"value":"0034-6748","type":"print"},{"value":"1089-7623","type":"electronic"}],"subject":[],"published-other":{"date-parts":[[2026,10]]},"published":{"date-parts":[[2026,10,1]]},"article-number":"103516"}}