{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T19:49:06Z","timestamp":1760298546643,"version":"3.41.2"},"reference-count":14,"publisher":"AIP Publishing","issue":"10","content-domain":{"domain":["pubs.aip.org"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2012,10,1]]},"abstract":"<jats:p>Based on the multi-foil technique, a multichannel soft x-ray diagnostic for electron temperature measurements has been recently implemented in the TJ-II stellarator. The diagnostic system is composed by four photodiodes arrays with beryllium filters of different thickness. An in-vacuum amplifier board is coupled to each array, aiming at preventing induced noise currents. The Thomson scattering and the vacuum ultraviolet survey diagnostics are used for assessing plasma profiles and composition, being the analysis carried out with the radiation code IONEQ. The electron temperature is determined through the different signal-pair ratios with temporal and spatial resolution. The design and preliminary results from the diagnostic are presented.<\/jats:p>","DOI":"10.1063\/1.4729669","type":"journal-article","created":{"date-parts":[[2012,6,18]],"date-time":"2012-06-18T22:15:51Z","timestamp":1340057751000},"update-policy":"https:\/\/doi.org\/10.1063\/aip-crossmark-policy-page","source":"Crossref","is-referenced-by-count":1,"title":["Implementation of a multichannel soft x-ray diagnostic for electron temperature measurements in TJ-II high-density plasmas"],"prefix":"10.1063","volume":"83","author":[{"given":"D.","family":"Bai\u00e3o","sequence":"first","affiliation":[{"name":"Universidade T\u00e9cnica de Lisboa 1 Associa\u00e7\u00e3o EURATOM\/IST, Instituto de Plasmas e Fus\u00e3o Nuclear, Instituto Superior T\u00e9cnico, , 1049-001 Lisboa, Portugal"}]},{"given":"F.","family":"Medina","sequence":"additional","affiliation":[{"name":"Laboratorio Nacional de Fusi\u00f3n 2 , Asociaci\u00f3n EURATOM-CIEMAT, 28040 Madrid, Spain"}]},{"given":"M.","family":"Ochando","sequence":"additional","affiliation":[{"name":"Laboratorio Nacional de Fusi\u00f3n 2 , Asociaci\u00f3n EURATOM-CIEMAT, 28040 Madrid, Spain"}]},{"given":"I.","family":"Pastor","sequence":"additional","affiliation":[{"name":"Laboratorio Nacional de Fusi\u00f3n 2 , Asociaci\u00f3n EURATOM-CIEMAT, 28040 Madrid, Spain"}]},{"given":"C.","family":"Varandas","sequence":"additional","affiliation":[{"name":"Universidade T\u00e9cnica de Lisboa 1 Associa\u00e7\u00e3o EURATOM\/IST, Instituto de Plasmas e Fus\u00e3o Nuclear, Instituto Superior T\u00e9cnico, , 1049-001 Lisboa, Portugal"}]},{"given":"A.","family":"Molinero","sequence":"additional","affiliation":[{"name":"Laboratorio General de Electr\u00f3nica y Autom\u00e1tica-CIEMAT 3 , 28040 Madrid, Spain"}]},{"given":"J.","family":"Ch\u00e9rcoles","sequence":"additional","affiliation":[{"name":"Laboratorio General de Electr\u00f3nica y Autom\u00e1tica-CIEMAT 3 , 28040 Madrid, Spain"}]}],"member":"317","published-online":{"date-parts":[[2012,6,18]]},"reference":[{"key":"2023070404074745600_c1","doi-asserted-by":"crossref","first-page":"131","DOI":"10.13182\/FST17-131-139","volume":"17","year":"1990","journal-title":"Fusion Technol."},{"key":"2023070404074745600_c2","doi-asserted-by":"publisher","first-page":"124051","DOI":"10.1088\/0741-3335\/50\/12\/124051","volume":"50","year":"2008","journal-title":"Plasma Phys. Controlled Fusion"},{"key":"2023070404074745600_c3","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1016\/j.jnucmat.2009.01.224","volume":"390-391","year":"2009","journal-title":"J. Nucl. Mater."},{"key":"2023070404074745600_c4","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1002\/ctpp.200900032","volume":"50","year":"2010","journal-title":"Contrib. Plasma Phys."},{"key":"2023070404074745600_c5","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1002\/ctpp.200900046","volume":"50","year":"2010","journal-title":"Contrib. Plasma Phys."},{"key":"2023070404074745600_c6","doi-asserted-by":"publisher","first-page":"763","DOI":"10.1063\/1.1149399","volume":"70","year":"1999","journal-title":"Rev. Sci. Instrum."},{"key":"2023070404074745600_c7","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1103\/PhysRev.119.843","volume":"119","year":"1960","journal-title":"Phys. Rev."},{"key":"2023070404074745600_c8","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1088\/0032-1028\/20\/12\/005","volume":"20","year":"1978","journal-title":"Plasma Phys."},{"key":"2023070404074745600_c9","doi-asserted-by":"publisher","first-page":"397","DOI":"10.1088\/0029-5515\/27\/3\/005","volume":"27","year":"1987","journal-title":"Nucl. Fusion"},{"key":"2023070404074745600_c10","doi-asserted-by":"publisher","first-page":"10D711","DOI":"10.1063\/1.3478561","volume":"81","year":"2010","journal-title":"Rev. Sci. Instrum."},{"first-page":"988","volume-title":"The Normal-Incidence Ultraviolet Spectrometer for the TJ-II and First Experimental Results","year":"2002","key":"2023070404074745600_c11"},{"key":"2023070404074745600_c12","unstructured":"A.\u2008Weller, D.\u2008Pasini, A. W.\u2008Edwards, R. D.\u2008Gill, R.\u2008Granetz, and JET Joint Undertaking, Report No. JET-IR (87)10, 1987."},{"key":"2023070404074745600_c13","doi-asserted-by":"publisher","first-page":"053501","DOI":"10.1063\/1.4714340","volume":"83","year":"2012","journal-title":"Rev. Sci. Instrum."},{"key":"2023070404074745600_c14"}],"container-title":["Review of Scientific Instruments"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4729669\/16062207\/10e104_1_online.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pubs.aip.org\/aip\/rsi\/article-pdf\/doi\/10.1063\/1.4729669\/16062207\/10e104_1_online.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,4]],"date-time":"2023-07-04T04:07:55Z","timestamp":1688443675000},"score":1,"resource":{"primary":{"URL":"https:\/\/pubs.aip.org\/rsi\/article\/83\/10\/10E104\/359474\/Implementation-of-a-multichannel-soft-x-ray"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,6,18]]},"references-count":14,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2012,10,1]]}},"URL":"https:\/\/doi.org\/10.1063\/1.4729669","relation":{},"ISSN":["0034-6748","1089-7623"],"issn-type":[{"type":"print","value":"0034-6748"},{"type":"electronic","value":"1089-7623"}],"subject":[],"published-other":{"date-parts":[[2012,10]]},"published":{"date-parts":[[2012,6,18]]},"article-number":"10E104"}}