{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T14:26:46Z","timestamp":1761056806672},"reference-count":32,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2001,3,1]],"date-time":"2001-03-01T00:00:00Z","timestamp":983404800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,7,17]],"date-time":"2013-07-17T00:00:00Z","timestamp":1374019200000},"content-version":"vor","delay-in-days":4521,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2001,3]]},"DOI":"10.1067\/mva.2001.111991","type":"journal-article","created":{"date-parts":[[2002,7,25]],"date-time":"2002-07-25T04:19:27Z","timestamp":1027570767000},"page":"546-553","source":"Crossref","is-referenced-by-count":5,"title":["Transfer function index of pulse volume recordings: A new method for vein graft surveillance"],"prefix":"10.1067","volume":"33","author":[{"given":"Leo H.M.","family":"Ihlberg","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sorjo","family":"M\u00e4tzke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.Anders","family":"Alb\u00e4ck","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wolf-Dieter","family":"Roth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anssi R.A.","family":"Sovij\u00e4rvi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mauri","family":"Lep\u00e4ntalo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1067\/mva.2001.111991_bib1","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1002\/bjs.1800790202","article-title":"Vein graft surveillance\u2014all part of the service","volume":"79","author":"Harris","year":"1992","journal-title":"Br J Surg"},{"key":"10.1067\/mva.2001.111991_bib2","first-page":"1","article-title":"Vein graft surveillance: is the case proven?","volume":"79","author":"Beattie","year":"1997","journal-title":"Ann R Coll Surg Engl"},{"key":"10.1067\/mva.2001.111991_bib3","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1053\/ejvs.1999.0935","article-title":"Does a completely accomplished duplex-based surveillance reverse vein graft failure?","volume":"18","author":"Ihlberg","year":"1999","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib4","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1016\/S1078-5884(96)80074-8","article-title":"The role of surveillance after infrainguinal bypass grafting: a review","volume":"11","author":"Giannoukas","year":"1996","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib5","doi-asserted-by":"crossref","first-page":"195","DOI":"10.1016\/0741-5214(93)90023-F","article-title":"The characteristics and anatomic distribution of lesions that cause reversed vein graft failure: a five-year prospective study","volume":"17","author":"Mills","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib6","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S0950-821X(05)80424-4","article-title":"Vein graft surveillance improves patency in femoro-popliteal bypass","volume":"4","author":"Moody","year":"1990","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib7","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1097\/00000658-199505000-00008","article-title":"Intensive surveillance of femoropopliteal-tibial autogenous vein bypasses improves long-term graft patency and limb salvage","volume":"221","author":"Bergamini","year":"1995","journal-title":"Ann Surg"},{"key":"10.1067\/mva.2001.111991_bib8","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1016\/S0741-5214(99)70171-0","article-title":"The correlation of early flow disturbances with the development of infrainguinal graft stenosis: a 10-year study of 341 autogenous vein grafts","volume":"30","author":"Ihnat","year":"1999","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib9","first-page":"1058","article-title":"Impact of a color-flow duplex surveillance program on infrainguinal vein graft patency: a five-year experience","volume":"15","author":"Idu","year":"1992","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib10","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/0741-5214(90)90039-D","article-title":"The importance of routine surveillance of distal bypass grafts with duplex scanning: a study of 379 reversed vein grafts","volume":"12","author":"Mills","year":"1990","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib11","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/S0741-5214(95)70241-5","article-title":"Femoropopliteal-crural graft patency is improved by an intensive surveillance program: a prospective randomised study","volume":"21","author":"Lundell","year":"1995","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib12","doi-asserted-by":"crossref","first-page":"716","DOI":"10.1067\/mva.1991.32966","article-title":"Color-flow duplex criteria for grading stenosis in infrainguinal vein grafts","volume":"14","author":"Buth","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib13","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1053\/ejvs.1999.1068","article-title":"Interobserver agreement in duplex scanning for vein grafts","volume":"19","author":"Ihlberg","year":"2000","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib14","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1016\/S1078-5884(98)80071-3","article-title":"A comparison between colour duplex ultrasonography and arteriography for imaging infrapopliteal arterial lesions","volume":"15","author":"Sensier","year":"1998","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib15","first-page":"63","article-title":"Vein graft surveillance: current trends","volume":"84","author":"Gibbs","year":"1997","journal-title":"Br J Surg"},{"key":"10.1067\/mva.2001.111991_bib16","doi-asserted-by":"crossref","first-page":"432","DOI":"10.1016\/S1078-5884(98)80206-2","article-title":"Economising vein-graft surveillance programs","volume":"15","author":"Idu","year":"1998","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib17","first-page":"873","article-title":"Quantitative segmental pulse volume recorder: a clinical tool","volume":"72","author":"Darling","year":"1972","journal-title":"Surgery"},{"key":"10.1067\/mva.2001.111991_bib18","first-page":"277","article-title":"Is it necessary to assess pressures after infrainguinal bypass?","author":"Lep\u00e4ntalo","year":"1996"},{"key":"10.1067\/mva.2001.111991_bib19","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"i","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"10.1067\/mva.2001.111991_bib20","first-page":"1020","article-title":"Revision of reversed infrainguinal bypass grafts without preoperative angiography","volume":"26","author":"Treiman","year":"1997","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib21","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/S0741-5214(98)70314-3","article-title":"Vein graft surveillance: is graft revision without angiography justified and what criteria should be used?","volume":"27","author":"Idu","year":"1998","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib22","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/S1078-5884(98)80187-1","article-title":"At what peak velocity ratio value should duplex-detected infrainguinal vein graft stenoses be revised?","volume":"15","author":"Olojugba","year":"1998","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib23","first-page":"799","article-title":"A low flow velocity predicts failure of femoropopliteal and femorotibial bypass grafts","volume":"98","author":"Bandyk","year":"1985","journal-title":"Surgery"},{"key":"10.1067\/mva.2001.111991_bib24","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1016\/0002-9610(89)90356-5","article-title":"Color-flow duplex screening of infrainguinal grafts combining low- and high-velocity criteria","volume":"158","author":"Sladen","year":"1989","journal-title":"Am J Surg"},{"key":"10.1067\/mva.2001.111991_bib25","first-page":"971","article-title":"Value of routine vascular laboratory studies to identify vein graft stenoses","volume":"90","author":"Berkowitz","year":"1981","journal-title":"Surgery"},{"key":"10.1067\/mva.2001.111991_bib26","doi-asserted-by":"crossref","first-page":"758","DOI":"10.1001\/archsurg.1986.01400070024004","article-title":"Recognition and management of impending graft failure","volume":"121","author":"Cohen","year":"1986","journal-title":"Arch Surg"},{"key":"10.1067\/mva.2001.111991_bib27","doi-asserted-by":"crossref","first-page":"284","DOI":"10.1016\/0741-5214(91)90221-F","article-title":"Impedance analysis to identify at risk femorodistal graft","volume":"13","author":"Wyatt","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib28","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0950-821X(05)80536-5","article-title":"Impedance analysis versus colour Duplex in femorodistal vein graft surveillance","volume":"7","author":"Davies","year":"1993","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2001.111991_bib29","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/0967-2109(96)82866-3","article-title":"Non-invasive impedance analysis: a new non-invasive test for graft surveillance","volume":"3","author":"Arora","year":"1995","journal-title":"Cardiovasc Surg"},{"key":"10.1067\/mva.2001.111991_bib30","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1001\/archsurg.1977.01370110069007","article-title":"Errors and artefacts of Doppler flowmeters and their solution","volume":"112","author":"Johnston","year":"1977","journal-title":"Arch Surg"},{"key":"10.1067\/mva.2001.111991_bib31","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1002\/bjs.1800710114","article-title":"Common femoral artery Doppler waveforms: a comparison of three methods of objective analysis with direct pressure measurements","volume":"71","author":"Macpherson","year":"1984","journal-title":"Br J Surg"},{"key":"10.1067\/mva.2001.111991_bib32","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1002\/bjs.1800710508","article-title":"A comparison between two types of waveform analysis in patients with multisegmental arterial disease","volume":"71","author":"Junger","year":"1984","journal-title":"Br J Surg"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521401156387?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521401156387?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,9]],"date-time":"2019-05-09T12:54:05Z","timestamp":1557406445000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521401156387"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,3]]},"references-count":32,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2001,3]]}},"alternative-id":["S0741521401156387"],"URL":"https:\/\/doi.org\/10.1067\/mva.2001.111991","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2001,3]]}}}