{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T13:04:30Z","timestamp":1760187870796},"reference-count":12,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2001,10,1]],"date-time":"2001-10-01T00:00:00Z","timestamp":1001894400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,7,17]],"date-time":"2013-07-17T00:00:00Z","timestamp":1374019200000},"content-version":"vor","delay-in-days":4307,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2001,10]]},"DOI":"10.1067\/mva.2001.119041","type":"journal-article","created":{"date-parts":[[2002,8,24]],"date-time":"2002-08-24T18:14:26Z","timestamp":1030212866000},"page":"577-580","source":"Crossref","is-referenced-by-count":11,"title":["Hemodynamic conditions at the carotid bifurcation during protective common carotid occlusion"],"prefix":"10.1067","volume":"34","author":[{"given":"Kenneth","family":"Ouriel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roy K.","family":"Greenberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Timur P.","family":"Sarac","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1067\/mva.2001.119041_bib1","doi-asserted-by":"crossref","first-page":"2281","DOI":"10.1161\/01.STR.26.12.2281","article-title":"Interpretation of embolic phenomena during carotid endarterectomy","volume":"26","author":"Smith","year":"1995","journal-title":"Stroke"},{"key":"10.1067\/mva.2001.119041_bib2","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1161\/01.STR.32.2.479","article-title":"Role of the distal balloon protection technique in the prevention of cerebral embolic events during carotid stent placement","volume":"32","author":"Martin","year":"2001","journal-title":"Stroke"},{"key":"10.1067\/mva.2001.119041_bib3","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/S0967-2109(98)00097-0","article-title":"Microemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomy","volume":"7","author":"Jordan","year":"1999","journal-title":"Cardiovasc Surg"},{"key":"10.1067\/mva.2001.119041_bib4","doi-asserted-by":"crossref","first-page":"504","DOI":"10.1067\/mva.2001.112278","article-title":"Efficacy of a proximal occlusion catheter with reversal of flow in the prevention of embolic events during carotid artery stenting: an experimental analysis","volume":"33","author":"Ohki","year":"2001","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.119041_bib5","doi-asserted-by":"crossref","first-page":"1034","DOI":"10.1016\/S0741-5214(99)70041-8","article-title":"Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: an ex vivo analysis","volume":"30","author":"Ohki","year":"1999","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.119041_bib6","first-page":"144","article-title":"Carotid stenting with and without protection devices: should protection be used in all patients?","volume":"13","author":"Ohki","year":"2000","journal-title":"Semin Vasc Surg"},{"key":"10.1067\/mva.2001.119041_bib7","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1583\/1074-6218(1996)003<0022:ROBAIT>2.0.CO;2","article-title":"Results of balloon angioplasty in the carotid arteries","volume":"3","author":"Kachel","year":"1996","journal-title":"J Endovasc Surg"},{"key":"10.1067\/mva.2001.119041_bib8","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1067\/mva.2000.109209","article-title":"Initial evaluation of carotid angioplasty and stenting with three different cerebral protection devices","volume":"32","author":"Parodi","year":"2000","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.119041_bib9","first-page":"869","article-title":"New triple coaxial catheter system for carotid angioplasty with cerebral protection","volume":"11","author":"Theron","year":"1990","journal-title":"Am J Neuroradiol"},{"key":"10.1067\/mva.2001.119041_bib10","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/0741-5214(91)90225-J","article-title":"Technique and clinical results of carotid stump back-pressure to determine selective shunting during carotid endarterectomy","volume":"13","author":"Archie","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2001.119041_bib11","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1111\/jon199554199","article-title":"Assessment of intracranial primary collaterals using transcranial color-coded real-time sonography","volume":"5","author":"Martin","year":"1995","journal-title":"J Neuroimaging"},{"key":"10.1067\/mva.2001.119041_bib12","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0741-5214(99)70185-0","article-title":"Locoregional versus general anesthesia in carotid surgery: is there an impact on perioperative myocardial ischemia? Results of a prospective monocentric randomized trial","volume":"30","author":"Sbarigia","year":"1999","journal-title":"J Vasc Surg"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S074152140112923X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S074152140112923X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,5,9]],"date-time":"2019-05-09T09:28:29Z","timestamp":1557394109000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S074152140112923X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2001,10]]},"references-count":12,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2001,10]]}},"alternative-id":["S074152140112923X"],"URL":"https:\/\/doi.org\/10.1067\/mva.2001.119041","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2001,10]]}}}