{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,26]],"date-time":"2026-04-26T10:13:25Z","timestamp":1777198405266,"version":"3.51.4"},"reference-count":37,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2002,4,1]],"date-time":"2002-04-01T00:00:00Z","timestamp":1017619200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2013,7,17]],"date-time":"2013-07-17T00:00:00Z","timestamp":1374019200000},"content-version":"vor","delay-in-days":4125,"URL":"https:\/\/www.elsevier.com\/open-access\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Journal of Vascular Surgery"],"published-print":{"date-parts":[[2002,4]]},"DOI":"10.1067\/mva.2002.119240","type":"journal-article","created":{"date-parts":[[2002,10,9]],"date-time":"2002-10-09T21:24:11Z","timestamp":1034198651000},"page":"759-765","source":"Crossref","is-referenced-by-count":15,"title":["Intraoperative angioscopy may improve the outcome of in situ saphenous vein bypass grafting: A prospective study"],"prefix":"10.1067","volume":"35","author":[{"given":"Johan","family":"Th\u00f6rne","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gudmundur","family":"Danielsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Danielsson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Torbj\u00f6rn","family":"Jonung","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lars","family":"Norgren","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Else","family":"Ribbe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zbigniew","family":"Zdanowski","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1067\/mva.2002.119240_bib1","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/0741-5214(92)70018-G","article-title":"Unsuspected preexisting saphenous vein disease: an unrecognised cause of vein by pass failure","volume":"15","author":"Panetta","year":"1992","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib2","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1177\/096721099300100509","article-title":"Ultrasonic characterisation of the saphenous vein","volume":"1","author":"Kupinski","year":"1993","journal-title":"Cardiovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib3","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.1016\/0741-5214(93)90674-B","article-title":"A modified, angioscopically assisted technique for in situ saphenous vein bypass: impact on patency, complications, and length of stay","volume":"17","author":"Maini","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib4","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/S0967-2109(97)00006-9","article-title":"Angioscopy in vascular surgery","volume":"5","author":"Rosenthal","year":"1997","journal-title":"Cardiovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib5","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1016\/S1078-5884(96)80111-0","article-title":"Angioscopically-assisted in situ saphenous vein bypass for infrainguinal revascularisation","volume":"12","author":"Wilson","year":"1996","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib6","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/S1078-5884(96)80129-8","article-title":"Angioscopy for quality control of saphenous vein during bypass grafting","volume":"11","author":"Wilson","year":"1996","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib7","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1002\/bjs.1800810502","article-title":"Vascular endoscopy: useful tool or interesting toy","volume":"81","author":"Stonebridge","year":"1994","journal-title":"Br J Surg"},{"key":"10.1067\/mva.2002.119240_bib8","first-page":"199","article-title":"Die Chirurgische Behandlung der peripheren Durch-blutungsst\u00f6rungen","volume":"5\/6","author":"Fontaine","year":"1954","journal-title":"Helvetia Chirurgica Acta"},{"key":"10.1067\/mva.2002.119240_bib9","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1016\/S0741-5214(95)70016-1","article-title":"Vein graft lesions: time of onset and rate of progression","volume":"22","author":"Caps","year":"1995","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib10","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/S0741-5214(98)70314-3","article-title":"Vein graft surveillance: is graft revision without angiography justified and what criteria should be used?","volume":"27","author":"Idu","year":"1998","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib11","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/S0741-5214(95)70241-5","article-title":"Femoropopliteal-crural graft patency is improved by an intensive surveillance program: a prospective randomized study","volume":"21","author":"Lundell","year":"1995","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib12","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0950-821X(89)80043-X","article-title":"Asymptomatic strictures in femoro-popliteal vein grafts","volume":"3","author":"Moody","year":"1989","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib13","series-title":"Surveillance of infrainguinal autologous vein bypasses","author":"Idu","year":"1998"},{"key":"10.1067\/mva.2002.119240_bib14","first-page":"431","article-title":"Intraoperative flow measurement of distal runoff: a valid predictor of outcome of infrainguinal bypass surgery","volume":"160","author":"Stirnemann","year":"1994","journal-title":"Eur J Surg"},{"key":"10.1067\/mva.2002.119240_bib15","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/S0950-821X(05)80720-0","article-title":"Prediction of early graft occlusion in femoropopliteal and femorodistal reconstruction by measurement of volume flow with a transit time flowmeter and calculation of peripheral resistance","volume":"7","author":"Lundell","year":"1993","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib16","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1053\/ejvs.1999.0935","article-title":"Does a completely accomplished duplex-based surveillance prevent vein-graft failure?","volume":"18","author":"Ihlberg","year":"1999","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib17","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/0741-5214(89)90414-X","article-title":"Postoperative predictive value of a new method of intraoperative angiographic assessment of run-off in femoropopliteal bypass grafting","volume":"10","author":"Karacagil","year":"1989","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib18","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1016\/S0741-5214(94)70210-1","article-title":"Randomized prospective study of angioscopically assisted in situ saphenous vein grafting","volume":"19","author":"Clair","year":"1994","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib19","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/0002-8703(89)90200-7","article-title":"Intraoperative angioscopy: principles of irrigation and description of a new dedicated irrigation pump","volume":"118","author":"Miller","year":"1989","journal-title":"Am Heart J"},{"key":"10.1067\/mva.2002.119240_bib20","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/0741-5214(91)90046-W","article-title":"Angioscopically directed valvulotome: a new valvulotome and technique","volume":"13","author":"Miller","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib21","first-page":"286","article-title":"Continued experience with intraoperative angioscopy for monitoring infrainguinal bypass grafting","volume":"109","author":"Miller","year":"1991","journal-title":"Surgery"},{"key":"10.1067\/mva.2002.119240_bib22","first-page":"3","article-title":"Vein quality in infrainguinal revascularisation: assessment by angioscopy and histology","volume":"80","author":"Wilson","year":"1998","journal-title":"Ann R Coll Surg Engl"},{"key":"10.1067\/mva.2002.119240_bib23","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/0741-5214(93)90258-N","article-title":"Saphenous vein biopsy: a predictor of vein graft failure","volume":"18","author":"Marin","year":"1993","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib24","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/S1078-5884(96)80046-3","article-title":"Vein graft stenosis: incidence and intervention","volume":"11","author":"Wilson","year":"1996","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib25","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/S0950-821X(05)80955-7","article-title":"The aetiology of vein graft stenoses","volume":"8","author":"Davies","year":"1994","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib26","doi-asserted-by":"crossref","first-page":"232","DOI":"10.1097\/00000658-197309000-00002","article-title":"Biologic fate of autogenous vein implants as arterial substitutes: clinical, angiographic and histopathologic observations in femoro-popliteal operations for atherosclerosis","volume":"178","author":"Szilagyi","year":"1973","journal-title":"Ann Surg"},{"key":"10.1067\/mva.2002.119240_bib27","first-page":"119","article-title":"The maintenance of arterial reconstruction","author":"Wolfe","year":"1991"},{"key":"10.1067\/mva.2002.119240_bib28","doi-asserted-by":"crossref","first-page":"1256","DOI":"10.1002\/bjs.1800781035","article-title":"Structural and functional smooth muscle injury after surgical preparation of reversed and non-reversed (in situ) saphenous vein bypass grafts","volume":"78","author":"Sayers","year":"1991","journal-title":"Br J Surg"},{"key":"10.1067\/mva.2002.119240_bib29","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1002\/path.1711590408","article-title":"Histological appearances of the long saphenous vein","volume":"159","author":"Milroy","year":"1989","journal-title":"J Pathol"},{"key":"10.1067\/mva.2002.119240_bib30","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1016\/S0950-821X(05)80625-5","article-title":"The aetiology of vein graft strictures: a prospective marker study","volume":"6","author":"Moody","year":"1992","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib31","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1016\/0741-5214(92)70020-L","article-title":"A blinded comparison of angiography, angioscopy, and duplex scanning in the intraoperative evaluation of in situ saphenous vein bypass grafts","volume":"15","author":"Gilbertson","year":"1992","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib32","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1016\/S0950-821X(05)80590-0","article-title":"Intraoperative imaging techniques in infrainguinal arterial bypass grafting: completion angiography versus vascular endoscopy","volume":"8","author":"Woelfe","year":"1994","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib33","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1016\/0741-5214(91)90304-D","article-title":"Endovascular management of arterial intimal defects: an experimental comparison by arteriography, angioscopy, and intravascular ultrasonography","volume":"13","author":"Neville","year":"1991","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib34","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/S0741-5214(99)70181-3","article-title":"Do residual arteriovenous fistulae after in situ saphenous vein bypass grafting influence patency?","volume":"30","author":"Lundell","year":"1999","journal-title":"J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib35","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/S0950-821X(87)80044-0","article-title":"The influence of patent branches on in situ vein graft haemodynamics","volume":"1","author":"Gwynn","year":"1987","journal-title":"Eur J Vasc Surg"},{"key":"10.1067\/mva.2002.119240_bib36","doi-asserted-by":"crossref","first-page":"439","DOI":"10.1016\/S1078-5884(97)80170-0","article-title":"Residual arteriovenous fistulae after \u201cclosed\u201d in situ bypass grafting: an overrated problem","volume":"13","author":"van Dijk","year":"1997","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"10.1067\/mva.2002.119240_bib37","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1016\/0741-5214(94)90137-6","article-title":"Infrainguinal endovascular in situ saphenous vein bypass: ongoing results","volume":"20","author":"Rosenthal","year":"1994","journal-title":"J Vasc Surg"}],"container-title":["Journal of Vascular Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521402941868?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0741521402941868?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,4,3]],"date-time":"2023-04-03T15:30:04Z","timestamp":1680535804000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0741521402941868"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,4]]},"references-count":37,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2002,4]]}},"alternative-id":["S0741521402941868"],"URL":"https:\/\/doi.org\/10.1067\/mva.2002.119240","relation":{},"ISSN":["0741-5214"],"issn-type":[{"value":"0741-5214","type":"print"}],"subject":[],"published":{"date-parts":[[2002,4]]}}}