{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T06:34:58Z","timestamp":1777876498967,"version":"3.51.4"},"reference-count":31,"publisher":"SAGE Publications","issue":"8","license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Perception"],"published-print":{"date-parts":[[2012,8]]},"abstract":"<jats:p>O'Shea and Crassini (1982, Perception &amp; Psychophysics32 195\u2013196) demonstrated that fusion persists for vertical lines with an orientation disparity of 8\u00b0, but diplopia is experienced in simultaneously presented horizontal lines with the same disparity. They concluded that the neural fusion process fuses larger horizontal disparities than vertical disparities. Kertesz criticised their demonstration because it did not quantify the possible motor component associated with fusing their counter-rotated images. Krekling and Blika argued that the demonstrated anisotropy is due to a disparity bias in the visual system, owing to the temporalward tilt of corresponding vertical meridians. We addressed these criticisms with a novel stimulus and presentation protocol, that rendered compensatory cyclovergence eye movements unlikely and explored a wide range of orientation disparities. We confirmed O'Shea and Crassini's vertical\/horizontal anisotropy in orientation fusion limits. In addition, our measurements of vertical lines showed that the distributions of fused responses as a function of orientation disparity in the upper and lower visual fields were shifted relative to each other. Therefore, the distributions of fusible orientation disparities are wider for vertical lines than horizontal lines and are relatively shifted as predicted if the fusional range is centred around the vertical horopter.<\/jats:p>","DOI":"10.1068\/p7091","type":"journal-article","created":{"date-parts":[[2013,1,3]],"date-time":"2013-01-03T12:20:39Z","timestamp":1357215639000},"page":"939-949","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":4,"title":["Horizontal\/Vertical Differences in Range and Upper\/Lower Visual Field Differences in the Midpoints of Sensory Fusion Limits of Oriented Lines"],"prefix":"10.1177","volume":"41","author":[{"given":"Philip M","family":"Grove","sequence":"first","affiliation":[{"name":"School of Psychology, The University of Queensland, St Lucia, QLD 4072, Australia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Ono","sequence":"additional","affiliation":[{"name":"Centre for Vision Research and Department of Psychology, York University, Toronto, Canada"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2012,1,1]]},"reference":[{"key":"bibr1-p7091","first-page":"3","volume":"7","author":"Ames A","year":"1926","journal-title":"American Journal of Optometry and Physiological Optics"},{"key":"bibr2-p7091","first-page":"741","volume":"33","author":"Beasley W C","year":"1936","journal-title":"Psychological Bulletin"},{"key":"bibr3-p7091","doi-asserted-by":"publisher","DOI":"10.1163\/156856897X00357"},{"key":"bibr4-p7091","doi-asserted-by":"publisher","DOI":"10.1167\/11.3.20"},{"key":"bibr5-p7091","doi-asserted-by":"publisher","DOI":"10.1007\/BF00410860"},{"key":"bibr6-p7091","doi-asserted-by":"publisher","DOI":"10.1068\/p3091"},{"key":"bibr7-p7091","unstructured":"Grove P M, Strike L, 2007 \u201cBinocular fusion limits around the vertical horopter\u201d, paper presented at\n                      the 5th Annual Asia Pacific Conference on Vision, Brisbane, Australia"},{"key":"bibr8-p7091","volume-title":"Helmholtz 's Treatise on Physiological Optics","volume":"3","author":"Helmholtz H","year":"1910"},{"key":"bibr9-p7091","volume-title":"Seeing in Depth volume 1 Basic Mechanisms","author":"Howard I P","year":"2002"},{"key":"bibr10-p7091","doi-asserted-by":"publisher","DOI":"10.1007\/BF00228705"},{"key":"bibr11-p7091","volume-title":"Seeing in Depth volume 2 Depth Perception","author":"Howard I P","year":"2002"},{"key":"bibr12-p7091","doi-asserted-by":"publisher","DOI":"10.1007\/BF02738410"},{"key":"bibr13-p7091","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(72)90163-0"},{"key":"bibr14-p7091","doi-asserted-by":"publisher","DOI":"10.3758\/BF03205873"},{"key":"bibr15-p7091","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(78)90204-3"},{"key":"bibr16-p7091","doi-asserted-by":"publisher","DOI":"10.3758\/BF03202961"},{"key":"bibr17-p7091","doi-asserted-by":"publisher","DOI":"10.1068\/p2738"},{"key":"bibr18-p7091","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(66)90052-6"},{"key":"bibr19-p7091","first-page":"2","volume":"120","author":"Nakayama K","year":"1977","journal-title":"Proceedings of the Society of Photo-Optical Instrumentation Engineers"},{"key":"bibr20-p7091","volume-title":"Researches in Binocular Vision","author":"Ogle K N","year":"1950"},{"key":"bibr21-p7091","doi-asserted-by":"publisher","DOI":"10.1037\/h0057643"},{"key":"bibr22-p7091","doi-asserted-by":"publisher","DOI":"10.3758\/BF03205917"},{"key":"bibr23-p7091","doi-asserted-by":"publisher","DOI":"10.3758\/BF03204280"},{"key":"bibr24-p7091","doi-asserted-by":"publisher","DOI":"10.1080\/713826374"},{"key":"bibr25-p7091","first-page":"695","volume":"32","author":"Rogers B J","year":"1991","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"bibr26-p7091","doi-asserted-by":"publisher","DOI":"10.1167\/8.3.7"},{"key":"bibr27-p7091","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.64.5.354"},{"key":"bibr28-p7091","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00252-1"},{"key":"bibr29-p7091","volume-title":"Foundations of Binocular Vision: A Clinical Perspective","author":"Steinman S","year":"2000"},{"key":"bibr30-p7091","first-page":"70","volume":"8","author":"Towne J","year":"1862","journal-title":"Guy's Hospital Reports"},{"key":"bibr31-p7091","doi-asserted-by":"publisher","DOI":"10.3758\/BF03194544"}],"container-title":["Perception"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1068\/p7091","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1068\/p7091","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T22:24:47Z","timestamp":1777587887000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1068\/p7091"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1,1]]},"references-count":31,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2012,8]]}},"alternative-id":["10.1068\/p7091"],"URL":"https:\/\/doi.org\/10.1068\/p7091","relation":{},"ISSN":["0301-0066","1468-4233"],"issn-type":[{"value":"0301-0066","type":"print"},{"value":"1468-4233","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,1,1]]}}}