{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T01:56:47Z","timestamp":1792115807242,"version":"4.4.0"},"reference-count":29,"publisher":"National Academy of Sciences","issue":"9","license":[{"start":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T00:00:00Z","timestamp":1581984000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["18-11-00178"],"award-info":[{"award-number":["18-11-00178"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.pnas.org"],"crossmark-restriction":true},"short-container-title":["Proc. Natl. Acad. Sci. U.S.A."],"published-print":{"date-parts":[[2020,3,3]]},"abstract":"<jats:p>A spectroscopic paradigm has been developed that allows the magnetic field emissions generated by the electrical activity in the human body to be imaged in real time. The growing significance of imaging modalities in biology is evident by the almost exponential increase of their use in research, from the molecular to the ecological level. The method of analysis described here allows totally noninvasive imaging of muscular activity (heart, somatic musculature). Such imaging can be obtained without additional methodological steps such as the use of contrast media.<\/jats:p>","DOI":"10.1073\/pnas.1913135117","type":"journal-article","created":{"date-parts":[[2020,2,18]],"date-time":"2020-02-18T18:14:37Z","timestamp":1582049677000},"page":"4942-4947","update-policy":"https:\/\/doi.org\/10.1073\/pnas.cm10313","source":"Crossref","is-referenced-by-count":24,"title":["Noninvasive muscle activity imaging using magnetography"],"prefix":"10.1073","volume":"117","author":[{"given":"Rodolfo R.","family":"Llin\u00e1s","sequence":"first","affiliation":[{"name":"Department of Neuroscience and Physiology, Center for Neuromagnetism, New York University School of Medicine, New York, New York, 10016;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikhail","family":"Ustinin","sequence":"additional","affiliation":[{"name":"Keldysh Institute of Applied Mathematics, Russian Academy of Sciences, Moscow, 125047 Russia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanislav","family":"Rykunov","sequence":"additional","affiliation":[{"name":"Keldysh Institute of Applied Mathematics, Russian Academy of Sciences, Moscow, 125047 Russia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kerry D.","family":"Walton","sequence":"additional","affiliation":[{"name":"Department of Neuroscience and Physiology, Center for Neuromagnetism, New York University School of Medicine, New York, New York, 10016;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guilherme M.","family":"Rabello","sequence":"additional","affiliation":[{"name":"Department of Neuroscience and Physiology, Center for Neuromagnetism, New York University School of Medicine, New York, New York, 10016;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John","family":"Garcia","sequence":"additional","affiliation":[{"name":"Department of Neuroscience and Physiology, Center for Neuromagnetism, New York University School of Medicine, New York, New York, 10016;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Boyko","sequence":"additional","affiliation":[{"name":"Keldysh Institute of Applied Mathematics, Russian Academy of Sciences, Moscow, 125047 Russia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vyacheslav","family":"Sychev","sequence":"additional","affiliation":[{"name":"Keldysh Institute of Applied Mathematics, Russian Academy of Sciences, Moscow, 125047 Russia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"341","published-online":{"date-parts":[[2020,2,18]]},"reference":[{"key":"e_1_3_4_1_2","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1186\/1752-0509-2-74","article-title":"A review of imaging techniques for systems biology","volume":"2","author":"Kherlopian A. R.","year":"2008","unstructured":"A. R. Kherlopian ., A review of imaging techniques for systems biology. BMC Syst. Biol. 2, 74 (2008).","journal-title":"BMC Syst. Biol."},{"key":"e_1_3_4_2_2","doi-asserted-by":"crossref","first-page":"5490","DOI":"10.1038\/s41598-019-41763-4","article-title":"Optical co-registration of MRI and on-scalp MEG","volume":"9","author":"Zetter R.","year":"2019","unstructured":"R. Zetter, J. Iivanainen, L. Parkkonen, Optical co-registration of MRI and on-scalp MEG. Sci. Rep. 9, 5490 (2019).","journal-title":"Sci. Rep."},{"key":"e_1_3_4_3_2","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1016\/j.neuroimage.2019.04.061","article-title":"The impact of improved MEG-MRI co-registration on MEG connectivity analysis","volume":"197","author":"Chella F.","year":"2019","unstructured":"F. Chella ., The impact of improved MEG-MRI co-registration on MEG connectivity analysis. Neuroimage 197, 354\u2013367 (2019).","journal-title":"Neuroimage"},{"key":"e_1_3_4_4_2","doi-asserted-by":"crossref","first-page":"080201","DOI":"10.1088\/1361-6668\/aacb14","article-title":"Focus on SQUIDs in biomagnetism","volume":"31","author":"Clarke J.","year":"2018","unstructured":"J. Clarke, Y.-H. Lee, J. Schneiderman, Focus on SQUIDs in biomagnetism. Supercond. Sci. Technol. 31, 080201 (2018).","journal-title":"Supercond. Sci. Technol."},{"key":"e_1_3_4_5_2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1258\/ebm.2009.009306","article-title":"Magnetic measurements of peripheral nerve function using a neuromagnetic current probe","volume":"235","author":"Wijesinghe R. S.","year":"2010","unstructured":"R. S. Wijesinghe, Magnetic measurements of peripheral nerve function using a neuromagnetic current probe. Exp. Biol. Med. (Maywood) 235, 159\u2013169 (2010).","journal-title":"Exp. Biol. Med. (Maywood)"},{"key":"e_1_3_4_6_2","doi-asserted-by":"crossref","first-page":"063001","DOI":"10.1088\/1361-6668\/aa66b3","article-title":"Recent advancements in the SQUID magnetospinogram system","volume":"30","author":"Adachi Y.","year":"2017","unstructured":"Y. Adachi ., Recent advancements in the SQUID magnetospinogram system. Supercond. Sci. Technol. 30, 063001 (2017).","journal-title":"Supercond. Sci. Technol."},{"key":"e_1_3_4_7_2","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1063\/1.1654294","article-title":"Magnetomyography: Magnetic fields around the human body produced by skeletal muscles","volume":"21","author":"Cohen D.","year":"1972","unstructured":"D. Cohen, E. Givler, Magnetomyography: Magnetic fields around the human body produced by skeletal muscles. Appl. Phys. Lett. 21, 114\u2013116 (1972).","journal-title":"Appl. Phys. Lett."},{"key":"e_1_3_4_8_2","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1002\/nau.23870","article-title":"Characterizing pelvic floor muscles activities using magnetomyography","volume":"38","author":"Escalona-Vargas D.","year":"2019","unstructured":"D. Escalona-Vargas, S. Oliphant, E. R. Siegel, H. Eswaran, Characterizing pelvic floor muscles activities using magnetomyography. Neurourol. Urodyn. 38, 151\u2013157 (2019).","journal-title":"Neurourol. Urodyn."},{"key":"e_1_3_4_9_2","doi-asserted-by":"crossref","first-page":"228","DOI":"10.3389\/fphys.2015.00228","article-title":"Magnetic fields from skeletal muscles: A valuable physiological measurement?","volume":"6","author":"Garcia M. A.","year":"2015","unstructured":"M. A. Garcia, O. Baffa, Magnetic fields from skeletal muscles: A valuable physiological measurement? Front. Physiol. 6, 228 (2015).","journal-title":"Front. Physiol."},{"key":"e_1_3_4_10_2","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/j.ajog.2016.08.002","article-title":"Magnetomyography of the levator muscle complex: A novel assessment tool","volume":"215","author":"Oliphant S.","year":"2016","unstructured":"S. Oliphant, D. Escalona-Vargas, B. Austin, H. Eswaran, Magnetomyography of the levator muscle complex: A novel assessment tool. Am. J. Obstet. Gynecol. 215, 667\u2013669 (2016).","journal-title":"Am. J. Obstet. Gynecol."},{"key":"e_1_3_4_11_2","doi-asserted-by":"crossref","first-page":"e0202184","DOI":"10.1371\/journal.pone.0202184","article-title":"Estimating uterine source current during contractions using magnetomyography measurements","volume":"13","author":"Zhang M.","year":"2018","unstructured":"M. Zhang, P. S. La Rosa, H. Eswaran, A. Nehorai, Estimating uterine source current during contractions using magnetomyography measurements. PLoS One 13, e0202184 (2018).","journal-title":"PLoS One"},{"key":"e_1_3_4_12_2","doi-asserted-by":"crossref","first-page":"1835","DOI":"10.1016\/j.ijcard.2012.12.056","article-title":"Diagnostic value of magnetocardiography in coronary artery disease and cardiac arrhythmias: A review of clinical data","volume":"167","author":"Kwong J. S.","year":"2013","unstructured":"J. S. Kwong, B. Leith\u00e4user, J. W. Park, C. M. Yu, Diagnostic value of magnetocardiography in coronary artery disease and cardiac arrhythmias: A review of clinical data. Int. J. Cardiol. 167, 1835\u20131842 (2013).","journal-title":"Int. J. Cardiol."},{"key":"e_1_3_4_13_2","first-page":"151","article-title":"Magnetocardiography: Current status and perspectives. Part II: Clinical applications","volume":"3","author":"Tavarozzi I.","year":"2002","unstructured":"I. Tavarozzi ., Magnetocardiography: Current status and perspectives. Part II: Clinical applications. Ital Heart J. 3, 151\u2013165 (2002).","journal-title":"Ital Heart J."},{"key":"e_1_3_4_14_2","first-page":"75","article-title":"Magnetocardiography: Current status and perspectives. Part I: Physical principles and instrumentation","volume":"3","author":"Tavarozzi I.","year":"2002","unstructured":"I. Tavarozzi ., Magnetocardiography: Current status and perspectives. Part I: Physical principles and instrumentation. Ital Heart J. 3, 75\u201385 (2002).","journal-title":"Ital Heart J."},{"key":"e_1_3_4_15_2","doi-asserted-by":"crossref","first-page":"5113","DOI":"10.1016\/j.ijcard.2013.07.238","article-title":"Thirty years of clinical magnetocardiography at the Catholic University of Rome: Diagnostic value and new perspectives for the treatment of cardiac arrhythmias","volume":"168","author":"Fenici R.","year":"2013","unstructured":"R. Fenici, D. Brisinda, A. Venuti, A. R. Sorbo, Thirty years of clinical magnetocardiography at the Catholic University of Rome: Diagnostic value and new perspectives for the treatment of cardiac arrhythmias. Int. J. Cardiol. 168, 5113\u20135115 (2013).","journal-title":"Int. J. Cardiol."},{"key":"e_1_3_4_16_2","doi-asserted-by":"crossref","first-page":"e12526","DOI":"10.1111\/anec.12526","article-title":"Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects","volume":"23","author":"Sorbo A. R.","year":"2018","unstructured":"A. R. Sorbo ., Unshielded magnetocardiography: Repeatability and reproducibility of automatically estimated ventricular repolarization parameters in 204 healthy subjects. Ann. Noninvasive Electrocardiol. 23, e12526 (2018).","journal-title":"Ann. Noninvasive Electrocardiol."},{"key":"e_1_3_4_17_2","unstructured":"R. R. Llinas M. N. Ustinin \u201cPrecise frequency-pattern analysis to decompose complex systems into functionally invariant entities.\u201d US Patent Office US20140107979 A1 (2014)."},{"key":"e_1_3_4_18_2","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3389\/fncir.2014.00043","article-title":"Frequency-pattern functional tomography of magnetoencephalography data allows new approach to the study of human brain organization","volume":"8","author":"Llin\u00e1s R. R.","year":"2014","unstructured":"R. R. Llin\u00e1s, M. N. Ustinin, Frequency-pattern functional tomography of magnetoencephalography data allows new approach to the study of human brain organization. Front. Neural Circuits 8, 43 (2014).","journal-title":"Front. Neural Circuits"},{"key":"e_1_3_4_19_2","first-page":"464","article-title":"New methology for the analysis and representation of human brain function: MEGMRIAn","volume":"9","author":"Ustinin M. N.","year":"2014","unstructured":"M. N. Ustinin, V. V. Sychev, K. D. Walton, R. R. Llinas, New methology for the analysis and representation of human brain function: MEGMRIAn. Math. Biol. Bioinf. 9, 464\u2013481 (2014).","journal-title":"Math. Biol. Bioinf."},{"key":"e_1_3_4_20_2","doi-asserted-by":"crossref","first-page":"373","DOI":"10.3389\/fnins.2015.00373","article-title":"Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data","volume":"9","author":"Llin\u00e1s R. R.","year":"2015","unstructured":"R. R. Llin\u00e1s ., Reconstruction of human brain spontaneous activity based on frequency-pattern analysis of magnetoencephalography data. Front. Neurosci. 9, 373 (2015).","journal-title":"Front. Neurosci."},{"key":"e_1_3_4_21_2","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1016\/0002-8703(63)90075-9","article-title":"Detection of the magnetic field of the heart","volume":"66","author":"Baule G.","year":"1963","unstructured":"G. Baule, R. McFee, Detection of the magnetic field of the heart. Am. Heart J. 66, 95\u201396 (1963).","journal-title":"Am. Heart J."},{"key":"e_1_3_4_22_2","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.jmmm.2018.12.011","article-title":"Study of anisotropy of magnetic noise, generated by magnetic particles in geomagnetic field","volume":"475","author":"Polikarpov M. A.","year":"2019","unstructured":"M. A. Polikarpov ., Study of anisotropy of magnetic noise, generated by magnetic particles in geomagnetic field. J. Magn. Magn. Mater. 475, 620\u2013626 (2019).","journal-title":"J. Magn. Magn. Mater."},{"key":"e_1_3_4_23_2","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.jmmm.2016.10.055","article-title":"3D imaging of magnetic particles using the 7-channel magnetoencephalographic device without pre-magnetization or displacement of the sample","volume":"427","author":"Polikarpov M. A.","year":"2017","unstructured":"M. A. Polikarpov ., 3D imaging of magnetic particles using the 7-channel magnetoencephalographic device without pre-magnetization or displacement of the sample. J. Magn. Magn. Mater. 427, 139\u2013143 (2017).","journal-title":"J. Magn. Magn. Mater."},{"key":"e_1_3_4_24_2","article-title":"Advanced electronics for the CTF MEG system","volume":"69","author":"McCubbin J.","year":"2004","unstructured":"J. McCubbin ., Advanced electronics for the CTF MEG system. Neurol. Clin. Neurophysiol. 69, (2004).","journal-title":"Neurol. Clin. Neurophysiol."},{"key":"e_1_3_4_25_2","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.pain.2010.02.023","article-title":"Abnormal thalamocortical activity in patients with complex regional pain syndrome (CRPS) type I","volume":"150","author":"Walton K. D.","year":"2010","unstructured":"K. D. Walton, M. Dubois, R. R. Llin\u00e1s, Abnormal thalamocortical activity in patients with complex regional pain syndrome (CRPS) type I. Pain 150, 41\u201351 (2010).","journal-title":"Pain"},{"key":"e_1_3_4_26_2","doi-asserted-by":"crossref","first-page":"69","DOI":"10.3389\/fnhum.2011.00069","article-title":"Imaging of thalamocortical dysrhythmia in neuropsychiatry","volume":"5","author":"Schulman J. J.","year":"2011","unstructured":"J. J. Schulman ., Imaging of thalamocortical dysrhythmia in neuropsychiatry. Front. Hum. Neurosci. 5, 69 (2011).","journal-title":"Front. Hum. Neurosci."},{"key":"e_1_3_4_27_2","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1109\/78.554307","article-title":"A blind source separation technique using second-order statistics","volume":"45","author":"Belouchrani A.","year":"1997","unstructured":"A. Belouchrani, K. Abed-Meraim, J.-F. Cardoso, E. Moulines, A blind source separation technique using second-order statistics. IEEE Trans. Signal Process. 45, 434\u2013444 (1997).","journal-title":"IEEE Trans. Signal Process."},{"key":"e_1_3_4_28_2","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1088\/0031-9155\/32\/1\/004","article-title":"Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem","volume":"32","author":"Sarvas J.","year":"1987","unstructured":"J. Sarvas, Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. Phys. Med. Biol. 32, 11\u201322 (1987).","journal-title":"Phys. Med. Biol."},{"key":"e_1_3_4_29_2","unstructured":"R. R. Llin\u00e1s . Data from \u201cNoninvasive muscle activity imaging using magnetography.\u201d Open Science Framework. https:\/\/doi.org\/10.17605\/OSF.IO\/TYZDV. Deposited 18 November 2019."}],"container-title":["Proceedings of the National Academy of Sciences"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.pnas.org\/syndication\/doi\/10.1073\/pnas.1913135117","content-type":"unspecified","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/pnas.org\/doi\/pdf\/10.1073\/pnas.1913135117","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,7]],"date-time":"2022-06-07T17:42:37Z","timestamp":1654623757000},"score":1,"resource":{"primary":{"URL":"https:\/\/pnas.org\/doi\/full\/10.1073\/pnas.1913135117"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,18]]},"references-count":29,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,3,3]]}},"alternative-id":["10.1073\/pnas.1913135117"],"URL":"https:\/\/doi.org\/10.1073\/pnas.1913135117","relation":{},"ISSN":["0027-8424","1091-6490"],"issn-type":[{"value":"0027-8424","type":"print"},{"value":"1091-6490","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,18]]},"assertion":[{"value":"2020-02-18","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}