{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T17:24:02Z","timestamp":1792689842526,"version":"4.5.0"},"reference-count":57,"publisher":"National Academy of Sciences","issue":"6","license":[{"start":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T00:00:00Z","timestamp":1769990400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100023581","name":"NSF | National Science Foundation Graduate Research Fellowship Program","doi-asserted-by":"publisher","award":["DGE 2140743"],"award-info":[{"award-number":["DGE 2140743"]}],"id":[{"id":"10.13039\/100023581","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100017567","name":"Apple","doi-asserted-by":"publisher","award":["General Purpose Handling Automation"],"award-info":[{"award-number":["General Purpose Handling Automation"]}],"id":[{"id":"10.13039\/100017567","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["www.pnas.org"],"crossmark-restriction":true},"short-container-title":["Proc. Natl. Acad. Sci. U.S.A."],"published-print":{"date-parts":[[2026,2,10]]},"abstract":"<jats:p>Rolling contact joints (RCJs) guide motion in robotic linkages, including manipulators, surgical devices, prosthetics, and more. In this work, we present a generalized optimization method to tailor the kinematic properties of RCJs by simultaneously optimizing both noncircular surface geometries and internal actuation pulley shapes. Our approach accommodates multiple joint types, including passively coupled systems with programmable spring stiffness as well as actuated single or multilink mechanisms. We explicitly incorporate common and practical manufacturing constraints into our optimization framework, such as size and convexity constraints. To demonstrate this approach, we optimize an RCJ designed to replicate the trajectory of a human knee, achieving a 99.6% reduction in alignment error compared to revolute joints and a 99.3% error reduction compared to circular RCJs. Additionally, we show that optimized RCJs increase the load-carrying capacity of a two-finger gripper by more than 3.5 times compared to a comparable circular-jointed design, showcasing how joint optimization can enhance robotic performance.<\/jats:p>","DOI":"10.1073\/pnas.2521406123","type":"journal-article","created":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T20:07:36Z","timestamp":1770062856000},"update-policy":"https:\/\/doi.org\/10.1073\/pnas.cm10313","source":"Crossref","is-referenced-by-count":2,"title":["Noncircular rolling contact joints enable programmed behavior in robotic linkages"],"prefix":"10.1073","volume":"123","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3458-2892","authenticated-orcid":false,"given":"Colter J.","family":"Decker","sequence":"first","affiliation":[{"name":"John A. Paulson School of Engineering and Applied Sciences","place":["Cambridge"]},{"name":"Harvard University","place":["Cambridge"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tony G.","family":"Chen","sequence":"additional","affiliation":[{"name":"John A. Paulson School of Engineering and Applied Sciences","place":["Cambridge"]},{"name":"Harvard University","place":["Cambridge"]},{"name":"George W. Woodruff School of Mechanical Engineering","place":["Atlanta"]},{"name":"Georgia Institute of Technology","place":["Atlanta"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michelle C.","family":"Yuen","sequence":"additional","affiliation":[{"name":"John A. Paulson School of Engineering and Applied Sciences","place":["Cambridge"]},{"name":"Harvard University","place":["Cambridge"]},{"name":"Department of Mechanical & Industrial Engineering","place":["Bozeman"]},{"name":"Montana State University","place":["Bozeman"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7969-038X","authenticated-orcid":false,"given":"Robert J.","family":"Wood","sequence":"additional","affiliation":[{"name":"John A. Paulson School of Engineering and Applied Sciences","place":["Cambridge"]},{"name":"Harvard University","place":["Cambridge"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"341","published-online":{"date-parts":[[2026,2,2]]},"reference":[{"key":"e_1_3_4_1_2","doi-asserted-by":"publisher","DOI":"10.1242\/jeb.110296"},{"key":"e_1_3_4_2_2","doi-asserted-by":"crossref","unstructured":"A. Hamon Y. Aoustin \u201cCross four-bar linkage for the knees of a planar bipedal robot\u201d in 2010 10th IEEE-RAS International Conference on Humanoid Robots (IEEE Nashville TN USA 2010) pp. 379\u2013384.","DOI":"10.1109\/ICHR.2010.5686851"},{"key":"e_1_3_4_3_2","doi-asserted-by":"crossref","unstructured":"A. D. Deshpande R. Balasubramanian R. Lin B. Dellon Y. Matsuoka \u201cUnderstanding variable moment arms for the index finger MCP joints through the ACT hand\u201d in 2008 2nd IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (IEEE 2008) pp. 776\u2013782.","DOI":"10.1109\/BIOROB.2008.4762911"},{"key":"e_1_3_4_4_2","doi-asserted-by":"publisher","DOI":"10.7554\/eLife.38190"},{"key":"e_1_3_4_5_2","doi-asserted-by":"crossref","unstructured":"C. W. Radcliffe Four-bar linkage prosthetic knee mechanisms: Kinematics alignment and prescription criteria. Prosthet. Orthot. Int. 18 159\u2013173 (1994).","DOI":"10.3109\/03093649409164401"},{"key":"e_1_3_4_6_2","doi-asserted-by":"crossref","unstructured":"T. Jansen Strandbeests. Archit. Des. 78 22\u201327 (2008) https:\/\/onlinelibrary.wiley.com\/doi\/pdf\/10.1002\/ad.701.","DOI":"10.1002\/ad.701"},{"key":"e_1_3_4_7_2","doi-asserted-by":"crossref","unstructured":"T. G. Nelson R. J. Lang S. P. Magleby L. L. Howell \u201cImplementation of rolling contacts for sorce joints\u201d in 2018 International Conference on Reconfigurable Mechanisms and Robots (ReMAR) J. L. Herder V. van der Wijk Eds. (IEEE 2018) pp. 1\u20138.","DOI":"10.1109\/REMAR.2018.8449870"},{"key":"e_1_3_4_8_2","doi-asserted-by":"crossref","unstructured":"J. R. Cannon C. P. Lusk L. L. Howell \u201cCompliant rolling-contact element mechanisms\u201d in Volume 7: 29th Mechanisms and Robotics Conference Parts A and B (ASMEDC Long Beach California USA 2005) pp. 3\u201313.","DOI":"10.1115\/DETC2005-84073"},{"key":"e_1_3_4_9_2","doi-asserted-by":"crossref","unstructured":"L. A. Shaw S. Chizari M. Dotson Y. Song J. B. Hopkins Compliant rolling-contact architected materials for shape reconfigurability. Nat. Commun. 9 4594 (2018).","DOI":"10.1038\/s41467-018-07073-5"},{"key":"e_1_3_4_10_2","doi-asserted-by":"crossref","unstructured":"Y. J. Kim Anthropomorphic low-inertia high-stiffness manipulator for high-speed safe interaction. IEEE Trans. Robot. 33 1358\u20131374 (2017).","DOI":"10.1109\/TRO.2017.2732354"},{"key":"e_1_3_4_11_2","first-page":"976","article-title":"Biomechanical comparative finite element analysis between a conventional proximal interphalangeal joint flexible hinge implant and a novel implant design using a rolling contact joint mechanism","volume":"18","author":"Kim Y. J.","year":"2023","unstructured":"Y. J. Kim, H. a. Bae, S. W. Hong, Biomechanical comparative finite element analysis between a conventional proximal interphalangeal joint flexible hinge implant and a novel implant design using a rolling contact joint mechanism. J. Orthop. Surg. Traumatol. 18, 976 (2023).","journal-title":"J. Orthop. Surg. Traumatol."},{"key":"e_1_3_4_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechmachtheory.2008.11.013"},{"key":"e_1_3_4_13_2","doi-asserted-by":"crossref","unstructured":"Y. Toshimitsu et al. \u201cGetting the ball rolling: Learning a dexterous policy for a biomimetic tendon-driven hand with rolling contact joints\u201d in 2023 IEEE-RAS 22nd International Conference on Humanoid Robots (Humanoids). (IEEE 2023) pp. 1\u20137.","DOI":"10.1109\/Humanoids57100.2023.10375231"},{"key":"e_1_3_4_14_2","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2019.2929988"},{"key":"e_1_3_4_15_2","doi-asserted-by":"crossref","unstructured":"M. Catalano et al. Adaptive synergies for the design and control of the Pisa\/IIT SoftHand. Int. J. Robot. Res. 33 768\u2013782 (2014).","DOI":"10.1177\/0278364913518998"},{"key":"e_1_3_4_16_2","doi-asserted-by":"crossref","unstructured":"A. Bersier et al. \u201cRotograb: Combining biomimetic hands with industrial grippers using a rotating thumb\u201d in 2024 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS) J. Dias Ed. (IEEE 2024) pp. 5303\u20135310.","DOI":"10.1109\/IROS58592.2024.10802788"},{"key":"e_1_3_4_17_2","doi-asserted-by":"crossref","unstructured":"K. Gilday C. Sirithunge F. Iida J. Hughes Embodied manipulation with past and future morphologies through an open parametric hand design. Sci. Robot. 10 eads6437 (2025).","DOI":"10.1126\/scirobotics.ads6437"},{"key":"e_1_3_4_18_2","doi-asserted-by":"crossref","unstructured":"H. Liu K. Xu B. Siciliano F. Ficuciello \u201cThe MERO hand: A mechanically robust anthropomorphic prosthetic hand using novel compliant rolling contact joint\u201d in 2019 IEEE\/ASME International Conference on Advanced Intelligent Mechatronics (AIM) (IEEE 2019) pp. 126\u2013132.","DOI":"10.1109\/AIM.2019.8868520"},{"key":"e_1_3_4_19_2","doi-asserted-by":"crossref","unstructured":"S. H. Kim H. In J. R. Song K. J. Cho \u201cForce characteristics of rolling contact joint for compact structure\u201d in 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob) (IEEE Singapore Singapore 2016) pp. 1207\u20131212.","DOI":"10.1109\/BIOROB.2016.7523795"},{"key":"e_1_3_4_20_2","doi-asserted-by":"crossref","unstructured":"J. Beil T. Asfour \u201cA rolling contact joint lower extremity exoskeleton knee\u201d in Intelligent Autonomous Systems 15 M. Strand R. Dillmann E. Menegatti S. Ghidoni Eds. (Springer International Publishing Cham 2019) pp. 263\u2013277.","DOI":"10.1007\/978-3-030-01370-7_21"},{"key":"e_1_3_4_21_2","doi-asserted-by":"crossref","unstructured":"S. Yu et al. Bio-inspired design of a self-aligning lightweight and highly-compliant cable-driven knee exoskeleton. Front. Hum. Neurosci. 16 1018160 (2022).","DOI":"10.3389\/fnhum.2022.1018160"},{"key":"e_1_3_4_22_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4055605"},{"key":"e_1_3_4_23_2","doi-asserted-by":"crossref","unstructured":"S. W. Hong J. Yoon Y. J. Kim H. S. Gong Novel implant design of the proximal interphalangeal joint using an optimized rolling contact joint mechanism. J. Orthop. Surg. Traumatol. 14 1\u201313 (2019).","DOI":"10.1186\/s13018-019-1234-6"},{"key":"e_1_3_4_24_2","doi-asserted-by":"publisher","DOI":"10.1089\/3dp.2022.0120"},{"key":"e_1_3_4_25_2","first-page":"218","article-title":"Two-DOFs bending forceps manipulator of 3.5-mm diameter for intrauterine fetus surgery: Feasibility evaluation","volume":"1","author":"Yamashita H.","year":"2006","unstructured":"H. Yamashita , Two-DOFs bending forceps manipulator of 3.5-mm diameter for intrauterine fetus surgery: Feasibility evaluation. Int. J. Comput. Assist. Radiol. Surg. 1, 218\u2013220 (2006).","journal-title":"Int. J. Comput. Assist. Radiol. Surg."},{"key":"e_1_3_4_26_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4004649"},{"key":"e_1_3_4_27_2","doi-asserted-by":"crossref","unstructured":"D. H. Lee M. Hwang J. Kim D. S. Kwon \u201cPayload optimization of surgical instruments with rolling joint mechanisms\u201d in 2020 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE 2020) pp. 3131\u20133136.","DOI":"10.1109\/IROS45743.2020.9341318"},{"key":"e_1_3_4_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-021-02442-w"},{"key":"e_1_3_4_29_2","doi-asserted-by":"crossref","unstructured":"Y. Hu L. Zhang W. Li G. Z. Yang Design and fabrication of a 3-D printed metallic flexible joint for snake-like surgical robot. IEEE Robot. Autom. Lett. 4 1557\u20131563 (2019).","DOI":"10.1109\/LRA.2019.2896475"},{"key":"e_1_3_4_30_2","doi-asserted-by":"crossref","unstructured":"P. Berthet-Rayne et al. \u201cRolling-joint design optimization for tendon driven snake-like surgical robots\u201d in 2018 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS) T. Maciejewski Ed. (IEEE 2018) pp. 4964\u20134971.","DOI":"10.1109\/IROS.2018.8593517"},{"key":"e_1_3_4_31_2","doi-asserted-by":"crossref","unstructured":"T. Hao Y. Ma J. Feng S. Liu J. Wang Design and implementation of a soft-rigid hybrid gripper with bionic ligaments and joint capsule. Soft Robot. 12 364\u2013373 (2025).","DOI":"10.1089\/soro.2024.0095"},{"key":"e_1_3_4_32_2","doi-asserted-by":"crossref","unstructured":"A. Jeanneau J. Herder T. Lalibert\u00e9 C. Gosselin \u201cA compliant rolling contact joint and its application in a 3-DOF planar parallel mechanism with kinematic analysis\u201d in Volume 2: 28th Biennial Mechanisms and Robotics Conference Parts A and B (ASMEDC Salt Lake City Utah USA 2004) pp. 689\u2013698.","DOI":"10.1115\/DETC2004-57264"},{"key":"e_1_3_4_33_2","doi-asserted-by":"crossref","unstructured":"S. Kim E. Sung J. Park ARC joint: Anthropomorphic rolling contact joint with kinematically variable torsional stiffness. IEEE Robot. Autom. Lett. 8 1810\u20131817 (2023).","DOI":"10.1109\/LRA.2023.3243439"},{"key":"e_1_3_4_34_2","doi-asserted-by":"crossref","unstructured":"J. M. Bern F. Zargarbashi A. Zhang J. Hughes D. Rus \u201cSimulation and fabrication of soft robots with embedded skeletons\u201d in 2022 International Conference on Robotics and Automation (ICRA) M. O\u2019Malley Ed. (IEEE 2022) pp. 5205\u20135211.","DOI":"10.1109\/ICRA46639.2022.9811844"},{"key":"e_1_3_4_35_2","doi-asserted-by":"publisher","DOI":"10.1115\/1.4035686"},{"key":"e_1_3_4_36_2","doi-asserted-by":"crossref","unstructured":"R. Wu L. Girardi S. Mintchev Encoding mechanical intelligence using ultraprogrammable joints. Sci. Adv. 11 eadv2052 (2025).","DOI":"10.1126\/sciadv.adv2052"},{"key":"e_1_3_4_37_2","doi-asserted-by":"crossref","unstructured":"M. C. Yuen C. J. Decker T. G. Chen R. J. Wood \u201cMagnetic sensing for proprioception of rolling contact joints\u201d in 2025 IEEE 8th International Conference on Soft Robotics (RoboSoft) (IEEE 2025) pp. 1\u20136.","DOI":"10.1109\/RoboSoft63089.2025.11020840"},{"key":"e_1_3_4_38_2","doi-asserted-by":"crossref","unstructured":"W. Zhang et al. \u201cTask-defined pulley design for nonlinearly coupled tendon-driven actuation\u201d in 2024 IEEE 7th International Conference on Soft Robotics (RoboSoft) (IEEE 2024) pp. 220\u2013227.","DOI":"10.1109\/RoboSoft60065.2024.10522021"},{"key":"e_1_3_4_39_2","doi-asserted-by":"crossref","unstructured":"J. M. Boisclair T. Lalibert\u00e9 C. Gosselin On the optimal design of underactuated fingers using rolling contact joints. IEEE Robot. Autom. Lett. 6 4656\u20134663 (2021).","DOI":"10.1109\/LRA.2021.3068976"},{"key":"e_1_3_4_40_2","doi-asserted-by":"crossref","unstructured":"R. Liang Z. Zhang W. Yang Q. Zhang \u201cGenetic algorithm-based optimization of the rolling-contact involute robot joints\u201d in 2023 IEEE 11th Joint International Information Technology and Artificial Intelligence Conference (ITAIC) (IEEE 2023) vol. 11 pp. 410\u2013414.","DOI":"10.1109\/ITAIC58329.2023.10409060"},{"key":"e_1_3_4_41_2","doi-asserted-by":"crossref","unstructured":"S. Shirafuji S. Ikemoto K. Hosoda Designing noncircular pulleys to realize target motion between two joints. IEEE\/ASME Trans. Mechatron. 22 487\u2013497 (2017).","DOI":"10.1109\/TMECH.2016.2614961"},{"key":"e_1_3_4_42_2","doi-asserted-by":"publisher","DOI":"10.1007\/s12532-018-0139-4"},{"key":"e_1_3_4_43_2","doi-asserted-by":"crossref","unstructured":"A. W\u00e4chter L. T. Biegler On the implementation of an interior-point filter line-search algorithm for large-scale nonlinear programming. Math. Program. 106 25\u201357 (2006).","DOI":"10.1007\/s10107-004-0559-y"},{"key":"e_1_3_4_44_2","doi-asserted-by":"publisher","DOI":"10.1109\/TNSRE.2006.881565"},{"key":"e_1_3_4_45_2","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2013.2278207"},{"key":"e_1_3_4_46_2","doi-asserted-by":"publisher","DOI":"10.1109\/TRO.2011.2178151"},{"key":"e_1_3_4_47_2","doi-asserted-by":"publisher","DOI":"10.1109\/LRA.2018.2864352"},{"key":"e_1_3_4_48_2","unstructured":"A. H. Slocum \u201cRolling contact orthopaedic joint design \u201d Thesis Massachusetts Institute of Technology (2013). https:\/\/dspace.mit.edu\/handle\/1721.1\/81736. Accepted 24 October 2013."},{"key":"e_1_3_4_49_2","doi-asserted-by":"crossref","unstructured":"S. H. Bang C. Gonzalez J. Ahn N. Paine L. Sentis Control and evaluation of a humanoid robot with rolling contact joints on its lower body. Front. Robot. AI 10 (2023).","DOI":"10.3389\/frobt.2023.1164660"},{"key":"e_1_3_4_50_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jbiomech.2010.02.001"},{"key":"e_1_3_4_51_2","doi-asserted-by":"publisher","DOI":"10.1682\/JRRD.1985.01.0009"},{"key":"e_1_3_4_52_2","doi-asserted-by":"crossref","unstructured":"E. Schwarm K. M. Gravesmill J. P. Whitney \u201cA floating-piston hydrostatic linear actuator and remote-direct-drive 2-DOF gripper\u201d in 2019 International Conference on Robotics and Automation (ICRA) A. Howard Ed. (IEEE 2019) pp. 7562\u20137568.","DOI":"10.1109\/ICRA.2019.8794378"},{"key":"e_1_3_4_53_2","doi-asserted-by":"crossref","unstructured":"C. B. Teeple T. N. Koutros M. A. Graule R. J. Wood Multi-segment soft robotic fingers enable robust precision grasping. Int. J. Robot. Res. 39 1647\u20131667 (2020).","DOI":"10.1177\/0278364920910465"},{"key":"e_1_3_4_54_2","doi-asserted-by":"crossref","unstructured":"L. U. Odhner et al. A compliant underactuated hand for robust manipulation. Int. J. Robot. Res. 33 736\u2013752 (2014).","DOI":"10.1177\/0278364913514466"},{"key":"e_1_3_4_55_2","doi-asserted-by":"crossref","unstructured":"R. Niiyama D. Rus S. Kim \u201cPouch motors: Printable\/inflatable soft actuators for robotics\u201d in 2014 IEEE International Conference on Robotics and Automation (ICRA) (IEEE 2014) pp. 6332\u20136337.","DOI":"10.1109\/ICRA.2014.6907793"},{"key":"e_1_3_4_56_2","volume-title":"Roark\u2019s Formulas for Stress and Strain, 8th Edition","author":"Young W.","year":"2011","unstructured":"W. Young, R. Budynas, A. Sadegh, Roark\u2019s Formulas for Stress and Strain, 8th Edition (McGraw Hill LLC, 2011)."},{"key":"e_1_3_4_57_2","unstructured":"C. Decker et al. harvard-microrobotics\/rcj-opt. Zenodo. https:\/\/zenodo.org\/records\/17015700. Deposited 1 January 2026."}],"container-title":["Proceedings of the National Academy of Sciences"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/pnas.org\/doi\/pdf\/10.1073\/pnas.2521406123","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,2,2]],"date-time":"2026-02-02T20:07:50Z","timestamp":1770062870000},"score":1,"resource":{"primary":{"URL":"https:\/\/pnas.org\/doi\/10.1073\/pnas.2521406123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,2]]},"references-count":57,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2026,2,10]]}},"alternative-id":["10.1073\/pnas.2521406123"],"URL":"https:\/\/doi.org\/10.1073\/pnas.2521406123","relation":{},"ISSN":["0027-8424","1091-6490"],"issn-type":[{"value":"0027-8424","type":"print"},{"value":"1091-6490","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,2,2]]},"assertion":[{"value":"2025-09-01","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-12-10","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-02","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"e2521406123"}}