{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,31]],"date-time":"2025-10-31T13:57:11Z","timestamp":1761919031447},"reference-count":24,"publisher":"Wiley","issue":"9","license":[{"start":{"date-parts":[[2010,12,31]],"date-time":"2010-12-31T00:00:00Z","timestamp":1293753600000},"content-version":"vor","delay-in-days":1217,"URL":"http:\/\/onlinelibrary.wiley.com\/termsAndConditions#vor"}],"content-domain":{"domain":["obgyn.onlinelibrary.wiley.com"],"crossmark-restriction":true},"short-container-title":["Acta Obstet Gynecol Scand"],"published-print":{"date-parts":[[2007,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A monitor (Spacelab 90207) was compared with sphygmomanometric blood pressure (BP) with respect to reproducibility and variations on precision and consistency. Some 133 women with type 1 diabetes mellitus and 59 non\u2010diabetic women were recruited. During pregnancy, systolic BP was between 6 and 12 mmHg higher in the oscillometric than the auscultatory readings, and diastolic BP was between 1 and 2.6 mmHg. The association of difference with the mean BP disappeared with progression of pregnancy and the repetition of measurements in diabetic pregnancy. The precision, reproducibility, and trend of association over the scale of measurement were improved in the repeated compared to individual measurements, whereas consistency did not improve.<\/jats:p>","DOI":"10.1080\/00016340701472773","type":"journal-article","created":{"date-parts":[[2007,8,22]],"date-time":"2007-08-22T12:16:29Z","timestamp":1187784989000},"page":"1063-1070","update-policy":"http:\/\/dx.doi.org\/10.1002\/crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Precision, consistency, and reproducibility of blood pressure in diabetic and non\u2010diabetic pregnancy: the appraisal of repeated measurements"],"prefix":"10.1111","volume":"86","author":[{"given":"FINN FRIIS","family":"LAUSZUS","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"ANNI","family":"ROSGAARD","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"THEA","family":"LOUSEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"OLE WINTHER","family":"RASMUSSEN","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"THOMAS MARTIN","family":"KLEBE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"JOACHIM G.","family":"KLEBE","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"311","published-online":{"date-parts":[[2010,12,31]]},"reference":[{"key":"e_1_2_6_2_2","doi-asserted-by":"publisher","DOI":"10.1067\/mob.2001.117664"},{"key":"e_1_2_6_3_2","doi-asserted-by":"publisher","DOI":"10.2337\/diacare.22.9.1507"},{"key":"e_1_2_6_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(98)70432-6"},{"key":"e_1_2_6_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0895-7061(02)03254-5"},{"key":"e_1_2_6_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0029-7844(96)00350-X"},{"key":"e_1_2_6_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9378(98)70520-4"},{"key":"e_1_2_6_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1994.tb13548.x"},{"key":"e_1_2_6_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9378(92)91829-Y"},{"key":"e_1_2_6_10_2","first-page":"337","article-title":"Blood pressure monitoring in diabetic pregnancy","volume":"33","author":"Napoli A","year":"1997","journal-title":"Ann Ist Super Sanit\u00e1"},{"key":"e_1_2_6_11_2","doi-asserted-by":"publisher","DOI":"10.1007\/s001250051471"},{"key":"e_1_2_6_12_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0412.2001.801204.x"},{"key":"e_1_2_6_13_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1993.tb15104.x"},{"key":"e_1_2_6_14_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1996.tb09671.x"},{"key":"e_1_2_6_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(86)90837-8"},{"issue":"6","key":"e_1_2_6_16_2","first-page":"S388","article-title":"Validation of the Spacelabs 90202 ambulatory blood pressure recorder","volume":"7","author":"O'Brien E","year":"1988","journal-title":"J Hypertens"},{"key":"e_1_2_6_17_2","first-page":"S19","article-title":"The need for a standardized protocol for validating non\u2010invasive ambulatory blood pressure measuring devices","volume":"7","author":"O'Brien E","year":"1989","journal-title":"J Hypertens Suppl"},{"key":"e_1_2_6_18_2","first-page":"211","article-title":"Validation study of the Spacelabs models 90202 and 5200 ambulatory blood pressure monitors","volume":"1","author":"Santucci S","year":"1988","journal-title":"J Ambulat Monit"},{"issue":"5","key":"e_1_2_6_19_2","first-page":"S282","article-title":"Accuracy of the SpaceLabs 90207 ambulatory blood pressure measuring system in normotensive pregnant women determined by the British Hypertension Society protocol","volume":"11","author":"O'Brien E","year":"1993","journal-title":"J Hypertens Suppl"},{"key":"e_1_2_6_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(90)93177-Q"},{"key":"e_1_2_6_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/S1056-8727(96)00065-7"},{"key":"e_1_2_6_22_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-199816080-00007"},{"key":"e_1_2_6_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1997.tb11468.x"},{"key":"e_1_2_6_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1471-0528.1993.tb15106.x"},{"key":"e_1_2_6_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/00004872-200406000-00009"}],"container-title":["Acta Obstetricia et Gynecologica Scandinavica"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.wiley.com\/onlinelibrary\/tdm\/v1\/articles\/10.1080%2F00016340701472773","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/pdf\/10.1080\/00016340701472773","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T02:17:46Z","timestamp":1695781066000},"score":1,"resource":{"primary":{"URL":"https:\/\/obgyn.onlinelibrary.wiley.com\/doi\/10.1080\/00016340701472773"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,9]]},"references-count":24,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2007,9]]}},"alternative-id":["10.1080\/00016340701472773"],"URL":"https:\/\/doi.org\/10.1080\/00016340701472773","archive":["Portico"],"relation":{},"ISSN":["0001-6349","1600-0412"],"issn-type":[{"value":"0001-6349","type":"print"},{"value":"1600-0412","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,9]]},"assertion":[{"value":"2010-12-31","order":2,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}