{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T13:38:20Z","timestamp":1777469900483,"version":"3.51.4"},"reference-count":0,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[1998,1,1]],"date-time":"1998-01-01T00:00:00Z","timestamp":883612800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Acta Radiol"],"published-print":{"date-parts":[[1998,1]]},"abstract":"<jats:p>Purpose: to compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases<\/jats:p>\n                  <jats:p>Material and Methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols<\/jats:p>\n                  <jats:p>Results: the high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). in patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details<\/jats:p>\n                  <jats:p>Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities<\/jats:p>","DOI":"10.1080\/02841859809172151","type":"journal-article","created":{"date-parts":[[2010,1,4]],"date-time":"2010-01-04T11:07:08Z","timestamp":1262603228000},"page":"60-63","source":"Crossref","is-referenced-by-count":3,"title":["Spiral CT of the pancreas"],"prefix":"10.1177","volume":"39","author":[{"given":"T.","family":"Nishiharu","sequence":"first","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Yamashita","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Ogata","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Sumi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Mitsuzaki","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Takahashi","sequence":"additional","affiliation":[{"name":"Department of Radiology, Kumamoto University School of Medicine, Kumamoto, Japan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2016,8,30]]},"container-title":["Acta Radiologica"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1080\/02841859809172151","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/journals.sagepub.com\/doi\/pdf\/10.1080\/02841859809172151","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T13:37:40Z","timestamp":1777383460000},"score":1,"resource":{"primary":{"URL":"http:\/\/journals.sagepub.com\/doi\/10.1080\/02841859809172151"}},"subtitle":["The value of small field-of-view targeted reconstruction"],"short-title":[],"issued":{"date-parts":[[1998,1]]},"references-count":0,"journal-issue":{"issue":"1","published-print":{"date-parts":[[1998,1]]}},"alternative-id":["10.1080\/02841859809172151"],"URL":"https:\/\/doi.org\/10.1080\/02841859809172151","relation":{},"ISSN":["0284-1851","1600-0455"],"issn-type":[{"value":"0284-1851","type":"print"},{"value":"1600-0455","type":"electronic"}],"subject":[],"published":{"date-parts":[[1998,1]]}}}