{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T07:12:12Z","timestamp":1759821132186,"version":"build-2065373602"},"reference-count":26,"publisher":"Informa UK Limited","issue":"1","license":[{"start":{"date-parts":[[2025,10,6]],"date-time":"2025-10-06T00:00:00Z","timestamp":1759708800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82460300"],"award-info":[{"award-number":["82460300"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"the Science Foundation of Guizhou Medical University"},{"name":"the Key Advantageous Discipline Construction Project of Guizhou Provincial Health Commission in Emergency Department","award":["22NSFCP46"],"award-info":[{"award-number":["22NSFCP46"]}]}],"content-domain":{"domain":["www.tandfonline.com"],"crossmark-restriction":true},"short-container-title":["Annals of Medicine"],"published-print":{"date-parts":[[2025,12,31]]},"DOI":"10.1080\/07853890.2025.2563000","type":"journal-article","created":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T06:48:41Z","timestamp":1759819721000},"update-policy":"https:\/\/doi.org\/10.1080\/tandf_crossmark_01","source":"Crossref","is-referenced-by-count":0,"title":["Efficacy and safety of different fixation methods for unstable anterior pelvic ring fractures: a Bayesian network meta-analysis"],"prefix":"10.1080","volume":"57","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-2228-2032","authenticated-orcid":false,"given":"Dongcheng","family":"Ran","sequence":"first","affiliation":[{"name":"Emergency Department, The Affiliated Hospital of Guizhou Medical University","place":["Guiyang, PR China"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-6459-8944","authenticated-orcid":false,"given":"Chunqing","family":"Wang","sequence":"additional","affiliation":[{"name":"Emergency Department, The Affiliated Hospital of Guizhou Medical University","place":["Guiyang, PR China"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"301","published-online":{"date-parts":[[2025,10,6]]},"reference":[{"key":"e_1_3_3_2_1","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-019-39068-7"},{"key":"e_1_3_3_3_1","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.18.01363"},{"issue":"23","key":"e_1_3_3_4_1","first-page":"4112","article-title":"Stabilization of unstable pelvic fractures with a novel internal-external fixator","volume":"124","author":"Jiang ZL","year":"2011","unstructured":"Jiang ZL, Chen G. Stabilization of unstable pelvic fractures with a novel internal-external fixator. Chin Med J (Engl). 2011;124(23):4112\u20134114.","journal-title":"Chin Med J (Engl)"},{"key":"e_1_3_3_5_1","doi-asserted-by":"publisher","DOI":"10.1186\/s13018-016-0397-7"},{"key":"e_1_3_3_6_1","doi-asserted-by":"publisher","DOI":"10.7326\/M14-2385"},{"key":"e_1_3_3_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/s10654-010-9491-z"},{"key":"e_1_3_3_8_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-011-1414-2"},{"issue":"22","key":"e_1_3_3_9_1","first-page":"2921","article-title":"Curative effect of minimally invasive percutaneous plate osteosynthesis and anterior subcutaneous internal fixator in the treatment of pelvic anterior ring fractures","volume":"32","author":"She J","year":"2021","unstructured":"She J, Ma L, Li M. Curative effect of minimally invasive percutaneous plate osteosynthesis and anterior subcutaneous internal fixator in the treatment of pelvic anterior ring fractures. Hainan Med J. 2021;32(22):2921\u20132924.","journal-title":"Hainan Med J"},{"key":"e_1_3_3_10_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00264-016-3387-9"},{"key":"e_1_3_3_11_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00402-017-2701-3"},{"issue":"11","key":"e_1_3_3_12_1","first-page":"4","article-title":"Comparison of application of different fixation methods of pelvic anterior ring in the treatment of pelvic anterior ring fractures","volume":"47","author":"Wang XY","year":"2019","unstructured":"Wang XY, Yu ZY, Zhang JS. Comparison of application of different fixation methods of pelvic anterior ring in the treatment of pelvic anterior ring fractures. Chin Clin Dr. 2019;47(11):4.","journal-title":"Chin Clin Dr"},{"issue":"3","key":"e_1_3_3_13_1","first-page":"284","article-title":"Internal fixation with modified Stoppa approach and external fixation for treatment of anterior pelvic ring fracture","volume":"22","author":"Cai CC","year":"2019","unstructured":"Cai CC, Xi YB, Luo HB. Internal fixation with modified Stoppa approach and external fixation for treatment of anterior pelvic ring fracture. Journal of Clinical Orthopaedics. 2019;22(3):284\u2013291.","journal-title":"Journal of Clinical Orthopaedics"},{"issue":"22","key":"e_1_3_3_14_1","first-page":"5","article-title":"Anterior subcutaneous screw- rod pelvic fixation versus external fixation for anterior pelvic ring fractures","volume":"28","author":"Yang KJ","year":"2020","unstructured":"Yang KJ, et al. Anterior subcutaneous screw- rod pelvic fixation versus external fixation for anterior pelvic ring fractures. Orthopedic Journal of China. 2020;28(22):5.","journal-title":"Orthopedic Journal of China"},{"issue":"1","key":"e_1_3_3_15_1","first-page":"6","article-title":"Comparative study of percutaneous bridging plate and retrograde suprapubic intramedullary screw fixation for anterior pelvic ring fracture","volume":"33","author":"Wang WB.","year":"2020","unstructured":"Wang WB. Comparative study of percutaneous bridging plate and retrograde suprapubic intramedullary screw fixation for anterior pelvic ring fracture. China J Orthop Trauma. 2020;33(1):6.","journal-title":"China J Orthop Trauma"},{"issue":"6","key":"e_1_3_3_16_1","first-page":"5","article-title":"Comparative study on the clinical results of hollow lag screw and reconstruction plate in pubic symphysis separation","volume":"13","author":"Tang GM","year":"2011","unstructured":"Tang GM, et al. Comparative study on the clinical results of hollow lag screw and reconstruction plate in pubic symphysis separation. J Trauma Surg. 2011;13(6):5.","journal-title":"J Trauma Surg"},{"issue":"24","key":"e_1_3_3_17_1","first-page":"4","article-title":"Comparison of clinical outcomes of bridge-link type combined fixation system versus locking plate for unstable pelvic fractures","volume":"28","author":"Liu C","year":"2020","unstructured":"Liu C, et al. Comparison of clinical outcomes of bridge-link type combined fixation system versus locking plate for unstable pelvic fractures. Orthopedic Journal of China. 2020;28(24):4.","journal-title":"Orthopedic Journal of China"},{"issue":"5","key":"e_1_3_3_18_1","first-page":"5","article-title":"Anterior pelvic external fixation versus internal anterior fixation in the treatment of anterior ring pelvic fractures","volume":"26","author":"Wang JC","year":"2020","unstructured":"Wang JC, Gao S, Tian SJ. Anterior pelvic external fixation versus internal anterior fixation in the treatment of anterior ring pelvic fractures. Journal of Practical Orthopaedics. 2020;26(5):5.","journal-title":"Journal of Practical Orthopaedics"},{"issue":"1","key":"e_1_3_3_19_1","first-page":"62","article-title":"Clinical observation on minimally invasive percutaneous steel plate internal fixation for the treatment of anterior pelvic ring fractures","volume":"63","author":"Tao YF","year":"2023","unstructured":"Tao YF, Jiang B, Zhu BB, et al. Clinical observation on minimally invasive percutaneous steel plate internal fixation for the treatment of anterior pelvic ring fractures. Shandong Medical Journal. 2023;63(1):62\u201364.","journal-title":"Shandong Medical Journal"},{"key":"e_1_3_3_20_1","article-title":"Effect of minimally invasive percutaneous bridge internal fixation in the treatment of unstable pelvic fractures","author":"Liu GQ","year":"2021","unstructured":"Liu GQ, Zeng LG, Xie L, et al. Effect of minimally invasive percutaneous bridge internal fixation in the treatment of unstable pelvic fractures. China Medical Herald. 2021;","journal-title":"China Medical Herald"},{"issue":"6","key":"e_1_3_3_21_1","first-page":"5","article-title":"Minimally invasive internal fixation for the treatment of 31 cases of Tile B type pelvic fractures","volume":"24","author":"Zhang L","year":"2018","unstructured":"Zhang L, Xu QL, Liang ZM, et al. Minimally invasive internal fixation for the treatment of 31 cases of Tile B type pelvic fractures. Chinese Journal of Surgery of Integrated Traditional and Western Medicine. 2018;24(6):5.","journal-title":"Chinese Journal of Surgery of Integrated Traditional and Western Medicine"},{"issue":"12","key":"e_1_3_3_22_1","first-page":"6","article-title":"Comparison of effectiveness of anterior subcutaneous internal fixator and plate internal fixation for unstable anterior pelvic ring fractures","volume":"34","author":"Yu X","year":"2020","unstructured":"Yu X, et al. Comparison of effectiveness of anterior subcutaneous internal fixator and plate internal fixation for unstable anterior pelvic ring fractures. Chinese Journal of Reparative and Reconstructive Surgery. 2020;34(12):6.","journal-title":"Chinese Journal of Reparative and Reconstructive Surgery"},{"key":"e_1_3_3_23_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.injury.2021.09.004"},{"key":"e_1_3_3_24_1","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-D-17-00839"},{"key":"e_1_3_3_25_1","doi-asserted-by":"publisher","DOI":"10.1097\/BOT.0000000000000032"},{"key":"e_1_3_3_26_1","doi-asserted-by":"publisher","DOI":"10.1097\/TA.0b013e3181568ce7"},{"key":"e_1_3_3_27_1","doi-asserted-by":"publisher","DOI":"10.3348\/kjr.2020.0675"}],"container-title":["Annals of Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/07853890.2025.2563000","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,7]],"date-time":"2025-10-07T06:48:44Z","timestamp":1759819724000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/07853890.2025.2563000"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,6]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2025,12,31]]}},"alternative-id":["10.1080\/07853890.2025.2563000"],"URL":"https:\/\/doi.org\/10.1080\/07853890.2025.2563000","relation":{},"ISSN":["0785-3890","1365-2060"],"issn-type":[{"value":"0785-3890","type":"print"},{"value":"1365-2060","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,6]]},"assertion":[{"value":"The publishing and review policy for this title is described in its Aims & Scope.","order":1,"name":"peerreview_statement","label":"Peer Review Statement"},{"value":"http:\/\/www.tandfonline.com\/action\/journalInformation?show=aimsScope&journalCode=iann20","URL":"http:\/\/www.tandfonline.com\/action\/journalInformation?show=aimsScope&journalCode=iann20","order":2,"name":"aims_and_scope_url","label":"Aim & Scope"},{"value":"2025-06-25","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-09-11","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-06","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}],"article-number":"2563000"}}