{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T05:25:35Z","timestamp":1787203535027,"version":"build-2736575974"},"reference-count":55,"publisher":"Informa UK Limited","license":[{"start":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T00:00:00Z","timestamp":1787097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/doi.org\/10.1080\/policies-text-data-mining"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Critical Reviews in Analytical Chemistry"],"DOI":"10.1080\/10408347.2026.2713115","type":"journal-article","created":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T04:59:03Z","timestamp":1787201943000},"page":"1-14","source":"Crossref","is-referenced-by-count":0,"title":["A Review of the Implementation of the USEPA Quality-Corrective Direction Performance Approach into Molecular Isotope-Dilution Mass Spectrometry Assays"],"prefix":"10.1080","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-4000-3643","authenticated-orcid":false,"given":"Yves","family":"Tondeur","sequence":"first","affiliation":[{"name":"It\u2019s About Purpose, LLC","place":["Carolina Beach, USA"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"301","published-online":{"date-parts":[[2026,8,19]]},"reference":[{"key":"e_1_3_3_2_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chroma.2005.05.090"},{"key":"e_1_3_3_3_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.chemosphere.2007.08.046"},{"key":"e_1_3_3_4_1","doi-asserted-by":"publisher","DOI":"10.1002\/rcm.5324"},{"key":"e_1_3_3_5_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.scitotenv.2022.154066"},{"key":"e_1_3_3_6_1","doi-asserted-by":"publisher","DOI":"10.3390\/molecules28135006"},{"key":"e_1_3_3_7_1","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-0716-3806-4_2"},{"key":"e_1_3_3_8_1","doi-asserted-by":"crossref","unstructured":"Environmental Protection Agency [FRL\u20135903\u20132] Performance Based Measurement System Notice of Intent. Federal Register\/Vol. 62 No. 193\/Monday October 6 1997\/Notices pp 52098\u201352100. DOI: 10.1007\/978-1-0716-3806-4_2.","DOI":"10.1007\/978-1-0716-3806-4_2"},{"key":"e_1_3_3_9_1","unstructured":"Office of Solid Waste and Emergency Response (OSWER) PBMS Implementation Plan October 9 1998 (revision 1) 1\u201352. A Cooperative Effort Among: OSW OERR OUST TIO FFRRO and CEPPO (USEPA Archive Document). Note: OSWER is now Office of Land and Emergency Management."},{"key":"e_1_3_3_10_1","doi-asserted-by":"crossref","unstructured":"Tondeur Y. Sustainable Quality Improvements for Isotope Dilution in Molecular Ultratrace Analyses \u2013 Fitness for Purpose Performance-Based Criteria and Measurement Uncertainty. Elsevier Amsterdam Netherlands; London United Kingdom; Cambridge MA United States; April 2024. [ISBN: 978-0-443-29034-3].","DOI":"10.1016\/B978-0-443-29034-3.00020-X"},{"key":"e_1_3_3_11_1","first-page":"27288","article-title":"Clean Water Act Methods Update Rule for the Analysis of Effluent, Federal Register","volume":"89","author":"USEPA","year":"2024","unstructured":"USEPA. Clean Water Act Methods Update Rule for the Analysis of Effluent, Federal Register. Rules and Regulations, 2024, 89, 27288\u201327327.","journal-title":"Rules and Regulations"},{"key":"e_1_3_3_12_1","unstructured":"SGS AXYS Method ATM 16130 (ATP Case No. NlB-0003) \u201cDetermination of 2 3 7 8-Substituted Tetra- through Octa-Chlorinated Dibenzo-p-Dioxins and Dibenzofurans (CDDs\/CDFs) using Waters and Agilent Gas Chromatography-Tandem-Mass Spectrometry (GC\/MS\/MS).\u201d See also: Pace Analytical Method PAM-16130-SSI (ATP Case No. N21-0001) \u201cDetermination of 2 3 7 8-Substituted Tetra- through Octa-Chlorinated Dibenzo-p-Dioxins and Dibenzofurans (CDDs\/CDFs) using Shimadzu Gas Chromatography Mass Spectrometry (GC-MS\/MS) Revision 1.1.\u201d 2020."},{"key":"e_1_3_3_13_1","doi-asserted-by":"publisher","DOI":"10.1007\/698_2016_460"},{"key":"e_1_3_3_14_1","doi-asserted-by":"publisher","DOI":"10.1007\/s00216-016-9428-9"},{"key":"e_1_3_3_15_1","unstructured":"USEPA. Federal Register. \/Vol. 90 No.12\/Tuesday January 21 2025\/Proposed Rules (MUR-22) pp. 6967\u20137037."},{"key":"e_1_3_3_16_1","unstructured":"The Agency Reemphasized the Flexible Approach in Method Selection with the Publication of the Methods Innovation Rule. MIR Fed. Regist. 2005 Vol. 70 No. 113\/Tuesday June 14 2005\/Rules and Regulations pp 34538\u201334592."},{"key":"e_1_3_3_17_1","unstructured":"Comparable Fuels Final Rule 63 FR 33782 June 19 1998. (USEPA Archive Document)"},{"key":"e_1_3_3_18_1","unstructured":"Crumbling D. M. Current Perspectives in Site Remediation and Monitoring - Using the triad approach to improve the cost-effectiveness of hazardous waste site cleanups EPA 542-R-01-016 October 2001 1\u20138."},{"key":"e_1_3_3_19_1","doi-asserted-by":"publisher","DOI":"10.1021\/ac00264a003"},{"key":"e_1_3_3_20_1","unstructured":"U.S. Environmental Protection Agency - Forum on Environmental Measurements - Flexible Approaches to Environmental Measurement - webinar series \u2013 question\/answer summary September 23 2010: Flexible Approaches to Environmental Measurement Webinar Series - Question\/Answer Summary."},{"key":"e_1_3_3_21_1","unstructured":"USEPA Data Quality Objectives for Superfund Interim Final Guidance Office of Emergency and Remedial Response EPA540-R-93-071 PB94-963203 September 1993 Washington DC 20460."},{"key":"e_1_3_3_22_1","unstructured":"USEPA Guidance for the Data Quality Objectives Process September 1994. EPA QA\/G-4 EPA\/600\/R-96\/055."},{"key":"e_1_3_3_23_1","unstructured":"USEPA Office of Environmental Information Guidance for the Data Quality Objectives Process EPA QA\/G-4 EPA\/600\/R-96\/055 August 2000: \u201cProject\/Program data quality objectives are qualitative and quantitative statements that clarify the intended use of the data define the type of data needed to support the decision identify the conditions under which data should be collected and specify tolerable limits on the probability of making a decision error because of uncertainty in the data (if applicable).\u201d Note: The classic quality controls in the relevant protocols are ineffective in assessing the trueness of the assays and therefore they are incapable of providing some of the required and critical \u201cperformance information.\u201d"},{"key":"e_1_3_3_24_1","unstructured":"Environmental Protection Agency [EPA\u2013HQ\u2013ORD; FRL\u20138930\u20133] Flexible Approaches to Environmental Measurement\u2014The Evolution of the Performance Approach Federal Register\/Vol. 74 No. 139\/Wednesday July 22 2009\/Notices pp. 36198\u201336200. Method Detection\/Quantitation Action Team."},{"key":"e_1_3_3_25_1","unstructured":"Recent updates reflecting a more realistic approach informed by practical laboratory input suggest a positive shift in perspective. For example there is now an openness to alternative methods for establishing detection and quantitation limits as well as more flexible ways to document and confirm performance where necessary. The primary challenge now is to ensure these changes move beyond theory and are implemented effectively. Furthermore there is a clear recognition of the essential role that Certified Reference Materials and effective lab-prepared materials play in accurately assessing data quality indicators such as accuracy. See for instance: Quality Assurance Program Plan for The Regional Monitoring Program for Water Quality in San Francisco Bay prepared by Yee D. Wong A. and Weaver M. San Francisco Estuary Institute Richmond CA 94804 SFEI Contribution Number 1169 2024."},{"key":"e_1_3_3_26_1","unstructured":"USEPA Definition and procedure for the determination of the method detection limit in: Appendix B to Part 136; 49 F.R. 43430 Oct. 26 1984; 50 F.R. 694 696 Jan. 4 1985 as Amended at 51 F.R. 23703 June 30 1986. For a recent version see: USEPA Definition and Procedure for the Determination of the Method Detection Limit in: Revision 2; Office of Water EPA 821-R-16-006 December 2016."},{"key":"e_1_3_3_27_1","unstructured":"USEPA. Method 1613: Tetra- Through Octachlorinated Dioxins and Furans by Isotope Dilution HRGC\/HRMS Office of Water EAD Washington DC October 1997 Revision B."},{"key":"e_1_3_3_28_1","unstructured":"Common misconceptions about reporting limits see for example: State Water Resources Control Board. SWAMP Bioaccumulation Monitoring Program Quality Assurance Project Plan. Surface Water Ambient Monitoring Program. Sacramento CA 2023. Traditionally sensitivity indicators rely on laboratory reporting limits (RL) rather than ACS-type LOQs which are necessary for reliable quantification. Both MDL and RL are unrelated to samples undergoing ID-MS and do not represent the performance characteristics required for recovery-corrected data. While the RL is often cited as accounting for matrix effects and dilutions it does not truly encapsulate matrix effects; only the ACS-LOQ or the USEPA Method 8290\u2019s EDL achieves this. Appendix L in Ref. 9 offers a procedure to validate the LOQ on a per sample- and analyte-basis (when and where needed) replacing the currently required (quarterly or annually) verification using field samples-unrelated spiked blanks. Furthermore dilutions do not modify calibration limits in ID-MS as the analyte-to-labeled-standard ratio is established at the spiking stage and remains unaffected by final extract dilution. Detection and quantitation limits should be driven by health-based regulatory requirements rather than laboratory qualifications. Contractors must determine the technical approach required to meet these project-specific objectives within acceptable uncertainty intervals."},{"key":"e_1_3_3_29_1","unstructured":"USEPA. Appendix A\u2014Test Methods Method 301\u2014Protocol for the Field Validation of Emission Concentrations from Stationary Sources available from the U.S. EPA Emission Measurement Technical Information Center Technical Support Division (MD-14) Research Triangle Park NC 27711 2004."},{"key":"e_1_3_3_30_1","unstructured":"EPA Method 23. Determination of Polychlorinated Dibenzo-p-Dioxins and Polychlorinated Dibenzofurans from Stationary Sources. Federal Register\/Vol. 88\/Monday March 20 2023\/rules and regulations pp 16732\u201316774. Note that the title does not include PCBs and PAHs which are part of this Final Rule (i.e. title used in the rule was not updated)."},{"key":"e_1_3_3_31_1","unstructured":"Commission Regulation (EU) 2017\/644 of 5 April 2017 laying down methods of sampling and analysis for the control of levels of dioxins dioxin-like PCBs and non-dioxin-like PCBs in certain foodstuffs and repealing Regulation (EU) No 589\/2014 (Text with EEA relevance) COMMISSION REGULATION (EU) 2017\/644."},{"key":"e_1_3_3_32_1","unstructured":"Eppe G.; Schaechtele A.; Haedrich J.; Fernandes A. Guidance Document on Measurement Uncertainty for Laboratories performing PCDD\/F and PCB Analysis using Isotope Dilution Mass Spectrometry Working Group for Measurement Uncertainty in PCDD\/F and PCB Analysis \u2013 2017."},{"key":"e_1_3_3_33_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0048-9697(97)05456-9"},{"key":"e_1_3_3_34_1","unstructured":"Similar to the Originally Intended Maximum Achievable Control Technology (MACT) Process: USEPA National Emission Standards for Hazardous Air Pollutants (NESHAP): Final Standards for Hazardous Air Pollutants for Hazardous Waste Combustors. Fed. Regist. 1999 64 52828."},{"key":"e_1_3_3_35_1","unstructured":"Systematic and random background contaminations: Laboratory method blanks are often used as measurement quality objectives for assay bias. While this approach addresses implicit systematic background contamination the lack of replicate method blanks in current protocols means there is no data on common sources of random contamination. To address this we should consider analyzing method blank results over 6-to-12-month periods for example. Individual sample results could then be compared to these means as well as to matrix-specific ACS-LOD\/LOQ values. Like the relationship between EDL and LOD[9] we could introduce a Laboratory Method Blank-Batch Specific Signal (LMBBSS)\u2014representing either a concentration (or an EMPC-estimated maximum possible concentration[9 44]) or an EDL for non-detected analytes (ND). This value would be compared to Laboratory Method Blank-Blank Control Limits (LMBBCL). The LMBBCL would be generated from the average of many method blanks (e.g. MinLMBBCL using only the average EDLLMB from the 20 most recent discontinuous method blanks whether the target analytes are detected or not[9] and MaxLMBBCL when both EDLLMB for NDs only and detected\/EMPC concentrations are considered) plus three standard deviations. Under this framework the MaxLMBBCL must be\u2009<\u2009x MinLMBBCL (x = 3 or 10 as defined by the user) and LMBBSS for target analytes must be\u2009<\u2009xMaxLMBBCL (where x = 0.1 0.3 or 1 depending on the user requirements). By deriving random contamination information from the standard deviation of average concentrations (detected\/EMPC and ND) in recent blanks this data becomes an integral part of the laboratory\u2019s performance self-diagnostic process and MU."},{"key":"e_1_3_3_36_1","unstructured":"Bias diagnosing bias: Let us consider a laboratory method blank (e.g. a 1-L deionized water sample) reported as an ND with an RL of 10\u2009pg\/L. In this scenario an actual detection of 9\u2009pg\/L (< RL) is observed during an assay with 100% labeled extraction standard recovery resulting in an EDL of 3\u2009pg\/L and with a generic MDL of 2\u2009pg\/L. If the labeled extraction standard recovery in the method blank drops to 20% the EDL automatically rises to approximately 15\u2009pg\/L (assuming all other factors remain unchanged) meaning the 9\u2009pg\/L contamination becomes truly undetectable. However the generic MDL remains fixed at 2\u2009pg\/L and the RL at 10\u2009pg\/L. Under this flawed MDL setup a facility discharging 11\u2009pg\/L (with an EDL of 3\u2009pg\/L) would be flagged for a permit violation since 11\u2009pg\/L exceeds the 10\u2009pg\/L regulatory limit. This exceedance is likely due to the laboratory\u2019s true performance issues\u2014specifically an \u201cacceptable\u201d or undiscernible background level of 9\u2009pg\/L or a recovery-uncorrected MDL that fails to reflect a 20% method blank efficiency inevitably resulting in a higher never-measured uncertainty interval."},{"key":"e_1_3_3_37_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.5c01955"},{"key":"e_1_3_3_38_1","doi-asserted-by":"publisher","DOI":"10.1021\/acs.analchem.4c05886"},{"key":"e_1_3_3_39_1","unstructured":"Title 40\u2014Protection of Environment Chapter I\u2014Environmental Protection Agency Subchapter D\u2014Water Programs Part 136\u2014Guidelines Establishing Test Procedures for the Analysis of Pollutants; 40 CFR 136.6; Aug. 20 2025."},{"key":"e_1_3_3_40_1","unstructured":"Guidelines and Format for Methods to be Proposed at 40 CFR Part 136 or Part 141. Prepared by Analytical Methods Staff Engineering and Analysis Division (4303) Office of Science and Technology Office of Water U. S. Environmental Protection Agency Washington DC; July 1996."},{"key":"e_1_3_3_41_1","unstructured":"USEPA. Method 1668A Interlaboratory Validation Study Report U.S. Environmental Protection Agency Office of Water Office of Science and Technology Engineering and Analysis Division (4303T) 1200 Pennsylvania Avenue NW Washington DC 20460; EPA-821-R-08-021 2008; see also Addendum to the Method 1668A Interlaboratory Validation Study Report March 2010 Pub. Number EPA-820-R-10-003."},{"key":"e_1_3_3_42_1","unstructured":"According to the Agency (reply to comments) the key differences are: \u2022 \u201cScope: Determinative technique is a broader concept encompassing the overall analytical strategy while a detector is a specific part of that strategy. \u2022 Function: The determinative technique dictates the fundamental approach to analysis while the detector converts the analyte\u2019s properties into a measurable signal. \u2022 Relationship: A determinative technique often utilizes one or more detectors to achieve its analytical goal. For example gas chromatography (a determinative technique) separates compounds which are then detected by a flame ionization detector (FID) thermal conductivity detector (TCD) or mass spectrometry (MS). In short the determinative technique outlines the \u2018what\u2019 and \u2018how\u2019 of the analysis (e.g. separating components by their boiling point or analyzing their interaction with light) and the detector is the specialized \u2018what\u2019 that actually registers the event or property of interest.\u201d Worth mentioning are the common mass spectrometer\u2019s detector types that include the electron multiplier Faraday cup array detectors and photomultipliers. The Agency considers change of equipment operating parameters such as changing the monitoring wavelength of a colorimeter as \u201cpotentially\u201d allowable under the Method Flexibility for Wastewater\u2014136.6. This highlights an inconsistency regarding the flexibility of method 1613. While changing the GC column liquid phase is permitted within the current framework (GC is a determinative technique) modifying the operation of the mass spectrometer detector is apparently not allowed without formal rulemaking. This remains the case even though mass spectrometry is explicitly identified as the determinative technique for the method."},{"key":"e_1_3_3_43_1","doi-asserted-by":"publisher","DOI":"10.1002\/bms.1200140812"},{"key":"e_1_3_3_44_1","first-page":"1856","article-title":"Choosing Between HRMS and MS\/MS: Environmental Applications, Environm","volume":"24","author":"Tondeur Y.","year":"1990","unstructured":"Tondeur, Y.; Charles, M. J. Choosing Between HRMS and MS\/MS: Environmental Applications, Environm. Sci. and Tech 1990, 24, 1856\u20131860.","journal-title":"Sci. and Tech"},{"key":"e_1_3_3_45_1","unstructured":"USEPA. Method 8290 Revision A: Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs) by High-Resolution Gas Chromatography\/High-Resolution Mass Spectrometry HRGC\/HRMS. January 1998. The original version dates to 1986 which was promulgated in 1987."},{"key":"e_1_3_3_46_1","unstructured":"Protocol for Review and Validation of New Methods for Regulated Organic and Inorganic Analytes in Wastewater Under EPA\u2019s Alternate Test Procedure Program EPA 821-B-18-001 February 2018; \u201cAcceptable modifications may use existing or emerging analytical technologies that achieve these ends provided that they do not depart substantially from the underlying chemical principles in methods currently approved in Part 136.\u201d Note that the ATP program evaluates methods but does not approve them."},{"key":"e_1_3_3_47_1","unstructured":"In the absence of chromatographic separation between specific compounds such as HxCDD isomers and 13C12-HxCDF congeners mass spectrometer resolving powers over 10 000 (<100\u2009ppm mass resolutions) are required for selected ion monitoring. While the MS\/MS approach resolves this by monitoring COCl losses unit resolution for MS-1 remains insufficient when dealing with coeluting interferences such as polychlorinated xanthenes. The overall selectivity of the assay depends on the selectivity of the extraction technique the sample fractionation and the determination system (HRGC\/HPLC and HRMS\/MS\/MS). Whenever mass resolution is challenged\u2014whether using high-resolution or unit-resolution tandem MS\u2014a judicious selection of GC\/LC columns should be considered. This practice is strongly encouraged under the performance-based approach. Under gas or liquid chromatography as the determinative technique the adoption of higher-performing GC or LC columns (including different GC mobile phase carrier gases or LC mobile phase eluents) is permitted without prior Agency approval. Given this flexibility why is the operation of a mass spectrometer detector still subjected to the formal rulemaking process when mass spectrometry remains the determinative technique?"},{"key":"e_1_3_3_48_1","unstructured":"By systematically ignoring the fact that isotope dilution requires specialized quality controls and serves as an ideal platform for implementing a performance-based approach the Agency is missing critical opportunities to eliminate major sources of systematic effects and reduce random errors. The Agency\u2019s current efforts to harmonize procedures across similar test methods and matrices undermine the DQO process. Furthermore these actions represent a violation of the certification requirements under ISO 17025."},{"key":"e_1_3_3_49_1","article-title":"Guidelines for Preparing Sampling and Analysis Plans Using Systematic Planning and PBMS","author":"Lesnik B.","year":"2001","unstructured":"Lesnik, B.; Crumbling, D. Guidelines for Preparing Sampling and Analysis Plans Using Systematic Planning and PBMS. Environmental Testing & Analysis 2001. See also[53].","journal-title":"Environmental Testing & Analysis"},{"key":"e_1_3_3_50_1","unstructured":"Tondeur Y. Measurement of Uncertainty: The sine qua non of Fitness for Purpose Air Quality & Emissions Virtual Event October 2021 https:\/\/youtu.be\/E2aOr3ildaw"},{"key":"e_1_3_3_51_1","unstructured":"If it is acknowledged that a \u201cone-size-fits-all\u201d approach is not realistic why is there a push to harmonize procedures across methods? For instance the use of MDL for ID-MS persists even when a more powerful tool like EDL is available. While harmonization is effectively applied to method modifications\u2014allowing quality enhancements without Agency approval provided performance requirements are met\u2014the same cannot be said for laboratory certification administration. Over the years the cost-effectiveness of certification has worsened displaying anti-PBMS characteristics by failing to prioritize flexibility and cost control. This is due to a variety of uncoordinated requirements from Agency regions government programs states and A&E firms that remain unadapted for ID."},{"key":"e_1_3_3_52_1","unstructured":"Such as for a project-specific or health-driven regulation-specific discharge limit of \u201c[x]\u201d pg\/L the user\u2014who ultimately must choose between two conditions\u2014might require the EDL to be less than an ACS-LOD of about \u201c[x\/3]\u201d pg\/L an ACS-LOQ of \u201c[x]\u201d pg\/L and an expanded uncertainty of \u201c[y]\u201d % at the 95% confidence level."},{"key":"e_1_3_3_53_1","doi-asserted-by":"crossref","unstructured":"See also Figures 1 and 2 in: Tondeur Y. A Review of the Implementation of the USEPA Quality-Corrective Direction Performance Approach into Molecular Isotope-Dilution Mass Spectrometry Assays: Part 1 \u2013 State of Affairs Critical Reviews in Analytical Chemistry DOI: 10.1080\/10408347.2026.2714239.","DOI":"10.1080\/10408347.2026.2714239"},{"key":"e_1_3_3_54_1","unstructured":"Crumbling D.; Lesnik B. Current Perspectives in Site Remediation and Monitoring-The Relationship between SW-846 PBMS and Innovative Analytical Technologies. EPA 542-R-01-015 October 2001."},{"key":"e_1_3_3_55_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.foodchem.2025.144771"},{"key":"e_1_3_3_56_1","unstructured":"One can also substitute \u201coperation\u201d or \u201clegislation\u201d with organization sampling and analysis plan and final report in support of the conclusions and decisions. For example also ask: How \u201cperfortable\u201d is your QAPP?"}],"container-title":["Critical Reviews in Analytical Chemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/10408347.2026.2713115","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.tandfonline.com\/doi\/full-xml\/10.1080\/10408347.2026.2713115","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/10408347.2026.2713115","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,20]],"date-time":"2026-08-20T04:59:11Z","timestamp":1787201951000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/10408347.2026.2713115"}},"subtitle":["Part 2\u2014Tailored Framework"],"short-title":[],"issued":{"date-parts":[[2026,8,19]]},"references-count":55,"alternative-id":["10.1080\/10408347.2026.2713115"],"URL":"https:\/\/doi.org\/10.1080\/10408347.2026.2713115","relation":{},"ISSN":["1040-8347","1547-6510"],"issn-type":[{"value":"1040-8347","type":"print"},{"value":"1547-6510","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,19]]}}}