{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T11:46:43Z","timestamp":1791546403347,"version":"4.3.4"},"reference-count":18,"publisher":"Informa UK Limited","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["International Journal of Occupational Safety and Ergonomics"],"published-print":{"date-parts":[[2004,1]]},"DOI":"10.1080\/10803548.2004.11076609","type":"journal-article","created":{"date-parts":[[2015,9,2]],"date-time":"2015-09-02T15:04:47Z","timestamp":1441206287000},"page":"215-226","source":"Crossref","is-referenced-by-count":30,"title":["Physiological Evaluation of Chemical Protective Suit Systems (CPSS) in Hot Conditions"],"prefix":"10.1080","volume":"10","author":[{"given":"Raija","family":"Ilmarinen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harri","family":"Lindholm","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kari","family":"Koivistoinen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petteri","family":"Helist\u00e9n","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"301","published-online":{"date-parts":[[2015,1,8]]},"reference":[{"key":"CIT0001","unstructured":"Ilmarinen R, Koivistoinen K. Heart rate and thermal responses in prolonged jobrelated firefighting drills. In: Hodgdon JA, Heaney JH, Buono MJ, editors. International Ergonomics VIII. International Series on Environmental Ergonomics. San Diego, CA, USA; International Conference on Environmental Ergonomics; 1998. vol. 1, p. 103\u20136."},{"key":"CIT0002","unstructured":"Ilmarinen R, Louhevaara V, Griefahn B, K\u00fcnemund C. Thermal and cardiac strain in strenuous fire-fighting and rescue tasks inthe extreme heat. In: Nielsen Johannsen B, Nielsen R, editors. Thermal Physiology. Proceedings from the 1997 Symposium of Thermal Physiology. Copenhagen, Denmark: August Krogh Institute; 1997. p. 127\u201330."},{"key":"CIT0003","unstructured":"Ilmarinen R, Louhevaara V, Griefahn B, K\u00fcnemund C. Thermal responses to consecutive strenuous fire-fighting and rescue tasks in the heat. In: Shapiro Y, Moran DS, Epstein Y, editors. Environmental physiology^recent progress and new frontiers. London, UK, and Tel Aviv, Israel: Freund Publishing House; 1997.p. 295\u20138."},{"key":"CIT0004","doi-asserted-by":"crossref","unstructured":"M\u00e4kinen H, Ilmarinen R, Griefahn B, K\u00fcnemund C. Physiological comparison of fire fighter turnout suits with and without a microporous membrane in the heat. In: Johnson JS, Mansdorf SZ, editors. Performance of Protective Clothing, Fifth Volume (ASTM STP 1237). West Conshohocken, PA, USA: American Society for Testing and Materials (ASTM); 1996. p. 396\u2013407.","DOI":"10.1520\/STP14083S"},{"key":"CIT0005","doi-asserted-by":"crossref","unstructured":"Selkirk GA, McLellan TM. Physical work limits for Toronto firefighters in warm environments. J Occup Environ Hyg 2004;1:199\u2013212.","DOI":"10.1080\/15459620490432114"},{"key":"CIT0006","unstructured":"McLellan TM, Jacobs I, Bain JB. Influence of temperature and metabolic rate on work performance with Canadian Forces NBC clothing. Aviat Space EnvironMed 1993;64:587\u201394."},{"key":"CIT0007","unstructured":"McLellan TM. Work performance at 40 \u00b0C with Canadian Forces biological and chemical protective clothing. Aviat Space Environ Med 1993;64:1094\u2013100."},{"key":"CIT0008","doi-asserted-by":"crossref","unstructured":"Carter BJ, Cammermyer M. Emergence of real casualities during simulated chemical warfare training under heat conditions. Milit Med 1985;150:657\u201365.","DOI":"10.1093\/milmed\/150.12.657"},{"key":"CIT0009","unstructured":"McLellan TM. Tolerance times for continuous work tasks while wearing NBC protective clothing in warm and hot environments and the stragedy of implementing rest chedules (DCIEM No. 94.62). Toronto, Ont., Canada: Defence and Civil Institue of Environmental Medicine (DCIEM); 1994."},{"key":"CIT0010","unstructured":"International Organization for Standardization (ISO). Hot environments\u2014estimation of the heat stress on working man, based on the WBGT-index (wet bulb globe temperature) (Standard No. ISO 7243:1982). Geneva, Switzerland: ISO; 1982."},{"key":"CIT0011","unstructured":"International Organization for Standardization (ISO). Ergonomics of the thermal environment\u2014analytical determination and interpretation of heat stress using calculation of the predicted heat strain (Standard No. ISO\/CD 7933:2001). Geneva, Switzerland: ISO; 2001."},{"key":"CIT0012","doi-asserted-by":"crossref","unstructured":"Smolander J, Ilmarinen R, Korhonen O, Pyykk\u00f6 I. Circulatory and thermal responses of men with different training status to prolonged physical work in dry and humid heat. Scand J Work Environ Health 1987;13:37\u201346.","DOI":"10.5271\/sjweh.2083"},{"key":"CIT0013","unstructured":"Ilmarinen R, Lindholm H, Koivistoinen K, Helist\u00e9n P. Physiological strain and wear comfort while wearing a chemical protective suit with breathing apparatus inside and outside the suit in summer and in winter. In: Kuklane K, Holmer I, editors. Ergonomics of protective clothing. Proceedings of OKOBETEF 6 and 1stEuropean Conference on Protective Clothing (Arbete och H\u00e4lsa No. 2000:8). Stockholm, Sweden: National Institute for Working Life. p. 235\u20138."},{"key":"CIT0014","doi-asserted-by":"crossref","unstructured":"Louhevaara V, Soukainen J, Lusa S, Tulppo M, Tuomi P, Kajaste T. Development and evaluation of a test drill for assessing physical work capacity of fire fighters. Int J Ind Erg 1994; 13:139\u201346.","DOI":"10.1016\/0169-8141(94)90080-9"},{"key":"CIT0015","unstructured":"European Committee for Standardization (CEN). Protective clothing against liquid and gaseous chemicals, including liquid aerosols and solid particles\u2014part 1: performance requirements for \u201cgas-tight\u201d (Type 1) and \u201cnon-gas-tight\u201d (Type 2) chemical protective suits for emergency teams (ET). (Standard No. EN 943\u20131: 2002). Brussels, Belgium: CEN; 2002."},{"key":"CIT0016","unstructured":"International Organization for Standardization (ISO). Evaluation of thermal strain by physiological measurements (Standard No. ISO 9886: 1992). Geneva, Switzerland: ISO; 1992."},{"key":"CIT0017","doi-asserted-by":"crossref","unstructured":"Borg G. Perceived exertion as an indicator of somatic stress. Scand J Rehabil Med 1970;2:92\u20138.","DOI":"10.2340\/1650197719702239298"},{"key":"CIT0018","unstructured":"International Organization for Standardization (ISO). Ergonomic of thermal environment\u2014asessment of the influence of the thermal environment using subjective judgement scales (Standard No. ISO 10551:1995). Geneva, Switzerland: ISO; 1995."}],"container-title":["International Journal of Occupational Safety and Ergonomics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/10803548.2004.11076609","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,13]],"date-time":"2023-08-13T17:12:50Z","timestamp":1691946770000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/10803548.2004.11076609"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,1]]},"references-count":18,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2015,1,8]]},"published-print":{"date-parts":[[2004,1]]}},"alternative-id":["10.1080\/10803548.2004.11076609"],"URL":"https:\/\/doi.org\/10.1080\/10803548.2004.11076609","relation":{},"ISSN":["1080-3548","2376-9130"],"issn-type":[{"value":"1080-3548","type":"print"},{"value":"2376-9130","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,1]]}}}