{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T03:58:59Z","timestamp":1777867139623,"version":"3.51.4"},"reference-count":59,"publisher":"Informa UK Limited","issue":"12","content-domain":{"domain":["www.tandfonline.com"],"crossmark-restriction":true},"short-container-title":["Expert Review of Medical Devices"],"published-print":{"date-parts":[[2025,12,2]]},"DOI":"10.1080\/17434440.2025.2580494","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T23:49:51Z","timestamp":1761695391000},"page":"1351-1359","update-policy":"https:\/\/doi.org\/10.1080\/tandf_crossmark_01","source":"Crossref","is-referenced-by-count":0,"title":["Optimizing atrial fibrillation detection: a review of subcutaneous cardiac rhythm monitors and consumer technologies"],"prefix":"10.1080","volume":"22","author":[{"given":"Michael","family":"Poliner","sequence":"first","affiliation":[{"name":"The Ohio State University","place":["Columbus, USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rayyan","family":"Bhutta","sequence":"additional","affiliation":[{"name":"Ohio University Heritage College of Osteopathic Medicine","place":["Athens, USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahmoud","family":"Gomaa","sequence":"additional","affiliation":[{"name":"The Ohio State University","place":["Columbus, USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muhmmad R.","family":"Afzal","sequence":"additional","affiliation":[{"name":"The Ohio State University","place":["Columbus, USA"]}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"301","published-online":{"date-parts":[[2025,11,16]]},"reference":[{"key":"e_1_3_4_3_1","unstructured":"U.S. Food and Drug Administration. Reveal insertable loop recorder (ILR) system 510(k) premarket notification. [cited 2024 Dec 10]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K972242"},{"key":"e_1_3_4_4_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2017.09.009"},{"key":"e_1_3_4_5_1","doi-asserted-by":"publisher","DOI":"10.1002\/joa3.12142"},{"key":"e_1_3_4_6_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2019.07.015"},{"key":"e_1_3_4_7_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.10.014"},{"key":"e_1_3_4_8_1","unstructured":"BIOMONITOR IV. Biotronik. [cited 2024 Dec 9]. Available from: https:\/\/www.biotronik.com\/en-us\/products\/crm\/arrhythmia-monitoring\/biomonitoriv"},{"key":"e_1_3_4_9_1","unstructured":"Radtke A Hall MAA AF & Pause Algorithms White Paper. 2023. Medtronic data on file."},{"key":"e_1_3_4_10_1","doi-asserted-by":"publisher","DOI":"10.1111\/jce.16007"},{"key":"e_1_3_4_11_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2022.03.336"},{"key":"e_1_3_4_12_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2022.02.013"},{"key":"e_1_3_4_13_1","doi-asserted-by":"publisher","DOI":"10.1056\/NEJMoa1901183"},{"key":"e_1_3_4_14_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejim.2019.11.018"},{"key":"e_1_3_4_15_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacc.2018.03.003"},{"key":"e_1_3_4_16_1","unstructured":"U.S. Food and Drug Administration. Samsung ECG app v 1.3 (ECG) 510(k) premarket notification. [cited 2024 Dec 9]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K240909"},{"key":"e_1_3_4_17_1","unstructured":"U.S. Food and Drug Administration. Fitbit ECG app 510(k) premarket notification. 2020 [cited 2024 Dec 9]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K200948"},{"key":"e_1_3_4_18_1","unstructured":"U.S. Food and Drug Administration. Garmin ECG app 510(k) premarket notification. 2023 Jan 12 [cited 2024 Dec 9]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfPMN\/pmn.cfm?ID=K221774"},{"key":"e_1_3_4_19_1","unstructured":"U.S. Food and Drug Administration. Withings scan monitor 2 0.510(k) premarket notification. [cited 2024 Dec 9]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K230812"},{"key":"e_1_3_4_20_1","unstructured":"U.S. Food and Drug Administration. Linq IITM insertable cardiac monitor (ICM) 510(k). Premarket Notification.; 2024 [cited 2024 Dec 3]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K240693"},{"key":"e_1_3_4_21_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2021.06.732"},{"key":"e_1_3_4_22_1","unstructured":"Medtronic. Linq IITM insertable cardiac monitor. [cited 2024 Dec 3]. Available from: https:\/\/europe.medtronic.com\/xd-en\/healthcare-professionals\/products\/cardiac-rhythm\/cardiac-monitors\/linq-ii.html"},{"key":"e_1_3_4_23_1","unstructured":"Assert-IQ insertable cardiac monitor. [cited 2024 Dec 3]. Available from: https:\/\/www.cardiovascular.abbott\/us\/en\/hcp\/products\/cardiac-rhythm-management\/insertable-cardiac-monitors\/assert-iq-icm.html"},{"key":"e_1_3_4_24_1","unstructured":"U.S. Food and Drug Administration. Assert-IQTM insertable cardiac monitor 510(k). Premarket Notification; 2023 [cited 2024 Dec 3]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfPMN\/pmn.cfm?ID=K230286"},{"key":"e_1_3_4_25_1","unstructured":"U.S. Food and Drug Administration. Lux-Dx II+TM 510(k) premarket notification. 2023 [cited 2024 Dec 4]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K231328"},{"key":"e_1_3_4_26_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2023.03.1498"},{"key":"e_1_3_4_27_1","unstructured":"Boston Scientific. Lux-Dx II+TM ICM system. [cited 2024 Dec 4]. Available from: https:\/\/www.bostonscientific.com\/en-US\/medical-specialties\/electrophysiology\/icm-lux-dx.html"},{"key":"e_1_3_4_28_1","doi-asserted-by":"publisher","DOI":"10.1093\/europace\/eux272"},{"key":"e_1_3_4_29_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2016.03.005"},{"key":"e_1_3_4_30_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurjcn\/zvac103"},{"key":"e_1_3_4_31_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2024.07.025"},{"key":"e_1_3_4_32_1","doi-asserted-by":"publisher","DOI":"10.1093\/ehjdh\/ztac026"},{"key":"e_1_3_4_33_1","doi-asserted-by":"publisher","DOI":"10.1111\/anec.12733"},{"key":"e_1_3_4_34_1","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.111.029801"},{"key":"e_1_3_4_35_1","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2021.1935873"},{"key":"e_1_3_4_36_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.123.032890"},{"key":"e_1_3_4_37_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jacep.2020.12.006"},{"key":"e_1_3_4_38_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2023.03.1075"},{"key":"e_1_3_4_39_1","doi-asserted-by":"publisher","DOI":"10.3390\/jcm14041052"},{"key":"e_1_3_4_40_1","doi-asserted-by":"publisher","DOI":"10.1111\/pace.13533"},{"key":"e_1_3_4_41_1","doi-asserted-by":"publisher","DOI":"10.1111\/anec.12864"},{"key":"e_1_3_4_42_1","doi-asserted-by":"publisher","DOI":"10.1161\/STROKEAHA.120.029340"},{"key":"e_1_3_4_43_1","doi-asserted-by":"publisher","DOI":"10.1177\/1747493020974561"},{"key":"e_1_3_4_44_1","doi-asserted-by":"publisher","DOI":"10.1002\/14651858.CD011637.pub2"},{"key":"e_1_3_4_45_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.acvd.2014.05.009"},{"key":"e_1_3_4_46_1","doi-asserted-by":"publisher","DOI":"10.1093\/eurheartj\/ehi602"},{"key":"e_1_3_4_47_1","doi-asserted-by":"publisher","DOI":"10.7326\/0003-4819-128-11-199806010-00002"},{"key":"e_1_3_4_48_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.hrthm.2025.01.011"},{"key":"e_1_3_4_49_1","unstructured":"U.S. Food and Drug Administration. Apple Inc ECG app De Novo classification request. 2018 [cited 2025 Feb 4]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/denovo.cfm?id=DEN180044"},{"key":"e_1_3_4_50_1","unstructured":"U.S. Food and Drug Administration. Apple Inc irregular rhythm notification feature de novo classification request. 2018 [cited 2025 Feb 5]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/denovo.cfm?id=DEN180042"},{"key":"e_1_3_4_51_1","unstructured":"U.S. Food and Drug Administration. Kardia band system 510(k) premarket notification. 2017 [cited 2025 Feb 5]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfPMN\/pmn.cfm?ID=K171816"},{"key":"e_1_3_4_52_1","doi-asserted-by":"publisher","DOI":"10.1093\/ehjdh\/ztab040"},{"key":"e_1_3_4_53_1","doi-asserted-by":"publisher","DOI":"10.2196\/26167"},{"key":"e_1_3_4_54_1","unstructured":"Monitor your heart rate with Apple Watch. Apple support. [cited 2024 Dec 9]. Available from: https:\/\/support.apple.com\/en-us\/120277"},{"key":"e_1_3_4_55_1","unstructured":"What is the meaning of the \u201ccontinuous recording\u201d? [cited 2024 Dec 9]. Available from: https:\/\/help.cardiogram.com\/article\/31-what-does-the-option-of-continuous-reading-mean#"},{"key":"e_1_3_4_56_1","doi-asserted-by":"publisher","DOI":"10.1016\/S0735-1097(19)30950-7"},{"key":"e_1_3_4_57_1","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.123.030543"},{"key":"e_1_3_4_58_1","doi-asserted-by":"publisher","DOI":"10.1016\/j.cvdhj.2023.12.003"},{"key":"e_1_3_4_59_1","unstructured":"U.S. Food and Drug Administration. Apple atrial fibrillation history feature medical device development tool (MDDT). 2023. Available from: https:\/\/www.fda.gov\/media\/178230\/download?attachment"},{"key":"e_1_3_4_60_1","unstructured":"U.S. Food and Drug Administration. Apple Inc. Atrial fibrillation history feature 510(k). Premarket Notification.; 2022 [cited 2025 Feb 5]. Available from: https:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpmn\/pmn.cfm?ID=K213971"},{"key":"e_1_3_4_61_1","unstructured":"Study details | the rhythm evaluation for anticoagulation with continuous monitoring of atrial fibrillation | ClinicalTrials.gov. [cited 2025 Feb 4]. Available from: https:\/\/www.clinicaltrials.gov\/study\/NCT05836987"}],"container-title":["Expert Review of Medical Devices"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/17434440.2025.2580494","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T09:53:21Z","timestamp":1777542801000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/17434440.2025.2580494"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,16]]},"references-count":59,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2025,12,2]]}},"alternative-id":["10.1080\/17434440.2025.2580494"],"URL":"https:\/\/doi.org\/10.1080\/17434440.2025.2580494","relation":{},"ISSN":["1743-4440","1745-2422"],"issn-type":[{"value":"1743-4440","type":"print"},{"value":"1745-2422","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,16]]},"assertion":[{"value":"The publishing and review policy for this title is described in its Aims & Scope.","order":1,"name":"peerreview_statement","label":"Peer Review Statement"},{"value":"http:\/\/www.tandfonline.com\/action\/journalInformation?show=aimsScope&journalCode=ierd20","URL":"http:\/\/www.tandfonline.com\/action\/journalInformation?show=aimsScope&journalCode=ierd20","order":2,"name":"aims_and_scope_url","label":"Aim & Scope"},{"value":"2025-05-09","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-22","order":2,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-11-16","order":3,"name":"published","label":"Published","group":{"name":"publication_history","label":"Publication History"}}]}}