{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T04:38:55Z","timestamp":1777869535527,"version":"3.51.4"},"reference-count":27,"publisher":"Informa UK Limited","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["HVAC&amp;R Research"],"published-print":{"date-parts":[[2007,11]]},"DOI":"10.1080\/10789669.2007.10391465","type":"journal-article","created":{"date-parts":[[2011,3,2]],"date-time":"2011-03-02T03:16:49Z","timestamp":1299035809000},"page":"971-986","source":"Crossref","is-referenced-by-count":65,"title":["Accuracy Limitations for Low-Velocity Measurements and Draft Assessment in Rooms"],"prefix":"10.1080","volume":"13","author":[{"given":"Arsen K.","family":"Melikov","sequence":"first","affiliation":[{"name":"a \r International Center for Indoor Environment and Energy, Department of Mechanical Engineering , Technical University of Denmark\r, Lyngby"}]},{"given":"Z.","family":"Popiolek","sequence":"additional","affiliation":[{"name":"b \r Department of Heating, Ventilation and Dust Removal Technology , Silesian University of Technology\r, Gliwice, \rPoland"}]},{"given":"M. C.G.","family":"Silva","sequence":"additional","affiliation":[{"name":"c \r ADAI, Department of Mechanical Engineering , University of Coimbra\u2013P\u00f3lo II\r, Coimbra, \rPortugal"}]},{"given":"I.","family":"Care","sequence":"additional","affiliation":[{"name":"d \r Metrology Division of CETIAT , Domaine Scientifique de la Doua\r, Villeurbanne Cedex, \rFrance"}]},{"given":"T.","family":"Sefker","sequence":"additional","affiliation":[{"name":"e \rTROX GmbH\r, Neukirchen-Vluyn, \rGermany"}]}],"member":"301","published-online":{"date-parts":[[2011,3]]},"reference":[{"key":"e_1_2_1_2_1","volume-title":"ANSI\/ASHRAE Standard 55\u20132004, Thermal Environmental Conditions for Human Occupancy","author":"ASHRAE","year":"2004","unstructured":"ASHRAE . 2004 . ANSI\/ASHRAE Standard 55\u20132004, Thermal Environmental Conditions for Human Occupancy Atlanta : American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ."},{"key":"e_1_2_1_3_1","volume-title":"ANSI\/ASHRAE Standard 113\u20132005, Method of Testing for Room Air Diffusion","author":"ASHRAE","year":"2005","unstructured":"ASHRAE . 2005 . ANSI\/ASHRAE Standard 113\u20132005, Method of Testing for Room Air Diffusion Atlanta : American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ."},{"key":"e_1_2_1_4_1","volume-title":"Ventilation for buildings: Design criteria for the indoor environment","author":"CEN","year":"1998","unstructured":"CEN . 1998 . Ventilation for buildings: Design criteria for the indoor environment Report 1752, European Committee for Standardization TC 156\/WG 6"},{"key":"e_1_2_1_5_1","volume-title":"ISO Standard 7730, Moderate Thermal Environments\u2014Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort","author":"EN","year":"1995","unstructured":"EN . 1995a . ISO Standard 7730, Moderate Thermal Environments\u2014Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort Geneva, , Switzerland : International Standard Organization for Standardization. ."},{"key":"e_1_2_1_6_1","volume-title":"Guide for the Expression of Uncertainty in Measurement","author":"EN","year":"1995","unstructured":"EN . 1995b . Guide for the Expression of Uncertainty in Measurement Geneva, , Switzerland : International Standard Organization for Standardization. ."},{"key":"e_1_2_1_7_1","volume-title":"ISO\/DIS Standard 7726, Ergonomics of the Thermal Environment\u2014Instruments for Measuring Physical Quantities","author":"EN","year":"1998","unstructured":"EN . 1998 . ISO\/DIS Standard 7726, Ergonomics of the Thermal Environment\u2014Instruments for Measuring Physical Quantities Geneva, , Switzerland : International Standard Organization for Standardization. ."},{"key":"e_1_2_1_8_1","volume-title":"ISO\/CD Standard 7730rev, Ergonomics of the Thermal Environment\u2014Analytical Determination and Interpretation of Thermal Comfort by Using Calculations of PMV and PPD Indices and Local Thermal Comfort Indices","author":"EN","year":"2003","unstructured":"EN . 2003 . ISO\/CD Standard 7730rev, Ergonomics of the Thermal Environment\u2014Analytical Determination and Interpretation of Thermal Comfort by Using Calculations of PMV and PPD Indices and Local Thermal Comfort Indices Geneva, , Switzerland : International Standard Organization for Standardization. ."},{"key":"e_1_2_1_9_1","first-page":"289","volume-title":"Proceedings of the Meeting of Commission B1, B2, E1 of the International Institute of Refrigeration","author":"Fanger P. O.","unstructured":"Fanger , P. O. and Pedersen , C. J.K. Discomfort due to air velocities in spaces . Proceedings of the Meeting of Commission B1, B2, E1 of the International Institute of Refrigeration . Belgrade, Yugoslavia. pp. 289 \u2013 96 ."},{"key":"e_1_2_1_10_1","doi-asserted-by":"publisher","DOI":"10.1016\/0378-7788(88)90053-9"},{"key":"e_1_2_1_11_1","first-page":"785","volume-title":"Proceedings of Indoor Air 1996","volume":"1","author":"Finkelstein W.","unstructured":"Finkelstein , W. , Melikov , A. K. , Sefker , T. and Langkilde , G. Laser Doppler measurements of airflow characteristics in rooms with mechanical ventilation . Proceedings of Indoor Air 1996 . Nagoya, Japan. Vol. 1 , pp. 785 \u2013 90 ."},{"key":"e_1_2_1_12_1","volume-title":"Proceedings of the 9th International Conference on Air Distribution in Rooms (ROOMVENT)","author":"Joergensen F. E.","unstructured":"Joergensen , F. E. , Popiolek , Z. , Melikov , A. K. and Silva , M. G. Total uncertainty of low velocity thermal anemometers for measurement of indoor air movements . Proceedings of the 9th International Conference on Air Distribution in Rooms (ROOMVENT) . Coimbra, Portugal."},{"key":"e_1_2_1_13_1","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/S0360-1323(01)00019-1","article-title":"Simulation and measurement of the stationary and transient characteristics of the hot sphere anemometer","volume":"37","author":"Loomans M. G.L.C.","year":"2002","unstructured":"Loomans , M. G.L.C. and Schijndel , A. W.M. 2002 . Simulation and measurement of the stationary and transient characteristics of the hot sphere anemometer . Building and Environment , 37 : 153 \u2013 63 .","journal-title":"Building and Environment"},{"key":"e_1_2_1_14_1","first-page":"263","volume-title":"Proceedings of ROOMVENT 1992","volume":"3","author":"Mayer E.","unstructured":"Mayer , E. New measurements of the convective heat transfer coefficient: Influences of turbulence, mean air velocity and geometry of the human body . Proceedings of ROOMVENT 1992 . Aalborg, Denmark. Vol. 3 , pp. 263 \u2013 76 ."},{"key":"e_1_2_1_15_1","first-page":"577","volume-title":"Proceedings of Healthy Buildings 1988","volume":"2","author":"Mayer E.","unstructured":"Mayer , E. and Schwab , R. Direction of low turbulent airflow and thermal comfort . Proceedings of Healthy Buildings 1988 . Stockholm, Sweden. Vol. 2 , pp. 577 \u2013 81 ."},{"key":"e_1_2_1_16_1","volume-title":"Accuracy of draught measurement","author":"Melikov A. K.","year":"2000","unstructured":"Melikov , A. K. 2000 . Accuracy of draught measurement Technical University of Denmark, Department of Energy Engineering. . Final Report, EC Research Project, Contract No. SMT4-CT97\u20132172"},{"key":"e_1_2_1_17_1","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0668.2004.00284.x"},{"key":"e_1_2_1_18_1","first-page":"291","article-title":"Low velocity measurements: Comparative study of different anemometers","volume":"3","author":"Melikov A. K.","year":"1992","unstructured":"Melikov , A. K. and Sawachi , T. 1992 . Low velocity measurements: Comparative study of different anemometers . Proceedings of International Conference ROOMVENT 1992, Aalborg, Denmark , 3 : 291 \u2013 306 .","journal-title":"Proceedings of International Conference ROOMVENT 1992, Aalborg, Denmark"},{"issue":"1","key":"e_1_2_1_19_1","first-page":"1491","article-title":"New method for testing dynamic characteristics of low velocity thermal anemometers","volume":"104","author":"Melikov A. K.","year":"1998","unstructured":"Melikov , A. K. , Popiolek , Z. and Joergensen , F. E. 1998a . New method for testing dynamic characteristics of low velocity thermal anemometers . ASHRAE Transactions , 104 ( 1b ) : 1491 \u2013 506 .","journal-title":"ASHRAE Transactions"},{"issue":"1","key":"e_1_2_1_20_1","first-page":"1529","article-title":"Requirements and guidelines for low velocity measurements","volume":"104","author":"Melikov A. K.","year":"1998","unstructured":"Melikov , A. K. , Popiolek , Z. , Finkelstein , W. , Sefker , T. and Care , I. 1998b . Requirements and guidelines for low velocity measurements . ASHRAE Transactions , 104 ( 1b ) : 1529 \u2013 539 .","journal-title":"ASHRAE Transactions"},{"key":"e_1_2_1_21_1","doi-asserted-by":"crossref","first-page":"1709","DOI":"10.1088\/0957-0233\/15\/9\/006","article-title":"Comparison of different methods for the determination of dynamic characteristics of low velocity anemometers","volume":"15","author":"Melikov A. K.","year":"2004","unstructured":"Melikov , A. K. and Popiolek , Z. 2004 . Comparison of different methods for the determination of dynamic characteristics of low velocity anemometers . Measurements Science and Technology , 15 : 1709 \u2013 715 .","journal-title":"Measurements Science and Technology"},{"issue":"1","key":"e_1_2_1_22_1","first-page":"1507","article-title":"Impact of natural convection on accuracy of low velocity measurements by thermal anemometers with omnidirectional sensor","volume":"104","author":"Popiolek Z.","year":"1998","unstructured":"Popiolek , Z. , Melikov , A. K. , Joergensen , F. E. , Finkelstein , W. and Sefker , T. 1998 . Impact of natural convection on accuracy of low velocity measurements by thermal anemometers with omnidirectional sensor . ASHRAE Transactions , 104 ( 1b ) : 1507 \u2013 518 .","journal-title":"ASHRAE Transactions"},{"key":"e_1_2_1_23_1","first-page":"2635","volume-title":"Proceedings of Indoor Air 2005","volume":"3","author":"Popiolek Z.","unstructured":"Popiolek , Z. and Melikov , A. K. A bench mark database and validation method for CFD predictions of airflow in a room . Proceedings of Indoor Air 2005 . Beijing, China. Vol. 3 , pp. 2635 \u2013 639 ."},{"key":"e_1_2_1_24_1","doi-asserted-by":"publisher","DOI":"10.1080\/14733315.2007.11683771"},{"issue":"1","key":"e_1_2_1_25_1","first-page":"1481","article-title":"Test method for describing directional sensitivity of anemometers for low velocity measurements indoors","volume":"04","author":"Stannov T.","year":"1998","unstructured":"Stannov , T. , Melikov , A. K. , Popiolek , Z. and Joergensen , F. E. 1998 . Test method for describing directional sensitivity of anemometers for low velocity measurements indoors . ASHRAE Transactions , 04 ( 1b ) : 1481 \u2013 489 .","journal-title":"ASHRAE Transactions"},{"key":"e_1_2_1_26_1","volume-title":"Proceedings of CLIMA 2000","author":"Toftum J.","unstructured":"Toftum , J. , Zhou , G. and Melikov , A. Effect of airflow direction on human perception of draught . Proceedings of CLIMA 2000 . August 30-September 2 , Brussels, Belgium. paper 366"},{"key":"e_1_2_1_27_1","first-page":"3357","volume-title":"Proceedings of Roomvent 2002","author":"Zhou G.","unstructured":"Zhou , G. and Melikov , A. Equivalent frequency\u2014A new parameter for description of frequency characteristics of airflow fluctuations . Proceedings of Roomvent 2002 . Copenhagen, Denmark. pp. 3357 \u2013 360 ."},{"key":"e_1_2_1_28_1","first-page":"297","volume-title":"Proceedings of Roomvent 2002","author":"Zhou G.","unstructured":"Zhou , G. , Melikov , A. K. and Fanger , P. O. Impact of equivalent frequency on the sensation of draught . Proceedings of Roomvent 2002 . Copenhagen, Denmark. pp. 297 \u2013 300 ."}],"container-title":["HVAC&amp;R Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.tandfonline.com\/doi\/pdf\/10.1080\/10789669.2007.10391465","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T16:38:12Z","timestamp":1700066292000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.tandfonline.com\/doi\/full\/10.1080\/10789669.2007.10391465"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,11]]},"references-count":27,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2007,11]]}},"alternative-id":["10.1080\/10789669.2007.10391465"],"URL":"https:\/\/doi.org\/10.1080\/10789669.2007.10391465","relation":{},"ISSN":["1078-9669","1938-5587"],"issn-type":[{"value":"1078-9669","type":"print"},{"value":"1938-5587","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,11]]}}}