{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T02:25:34Z","timestamp":1791253534316,"version":"4.1.0"},"reference-count":24,"publisher":"Cambridge University Press (CUP)","issue":"12","license":[{"start":{"date-parts":[[2015,1,2]],"date-time":"2015-01-02T00:00:00Z","timestamp":1420156800000},"content-version":"unspecified","delay-in-days":5511,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infect. Control Hosp. Epidemiol."],"published-print":{"date-parts":[[1999,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"S0195941700072970_abs1\"><jats:title>Objective:<\/jats:title><jats:p>To investigate an increase in reports of legionnaires' disease by multiple hospitals in San Antonio, Texas, and to study risk factors for nosocomial transmission of legionnaires' disease and determinants for<jats:italic>Legionella<\/jats:italic>colonization of hospital hot-water systems.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700072970_abs2\"><jats:title>Setting:<\/jats:title><jats:p>The 16 largest hospitals in the cities of San Antonio, Temple, and Austin, Texas.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700072970_abs3\"><jats:title>Design:<\/jats:title><jats:p>Review of laboratory databases to identify patients with legionnaires' disease in the 3 years prior to the investigation and to determine the number of diagnostic tests for<jats:italic>Legionella<\/jats:italic>performed; measurement of hot-water temperature and chlorine concentration and culture of potable water for<jats:italic>Legionella<\/jats:italic>. Exact univariate calculations, Poisson regression, and linear regression were used to determine factors associated with water-system colonization and transmission of<jats:italic>Legionella<\/jats:italic>.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700072970_abs4\"><jats:title>Results:<\/jats:title><jats:p>Twelve cases of nosocomial legionnaires' disease were identified; eight of these occurred in 1996. The rise in cases occurred shortly after physicians started requesting<jats:italic>Legionella<\/jats:italic>urinary antigen tests. Hospitals that frequently used<jats:italic>Legionella<\/jats:italic>urinary antigen tests tended to detect more cases of legionnaires' disease.<jats:italic>Legionella<\/jats:italic>was isolated from the water systems of 11 of 12 hospitals in San Antonio; the 12th had just experienced an outbreak of legionnaires' disease and had implemented control measures. Nosocomial legionellosis cases probably occurred in 5 hospitals. The number of nosocomial legionnaires' disease cases in each hospital correlated better with the proportion of water-system sites that tested positive for<jats:italic>Legionella (P<\/jats:italic>=.07) than with the concentration of<jats:italic>Legionella<\/jats:italic>bacteria in water samples (<jats:italic>P<\/jats:italic>=.23). Hospitals in municipalities where the water treatment plant used monochloramine as a residual disinfectant (n=4) and the hospital that had implemented control measures were<jats:italic>Legionella<\/jats:italic>-free. The hot-water systems of all other hospitals (n=11) were colonized with<jats:italic>Legionella<\/jats:italic>. These were all supplied with municipal drinking water that contained free chlorine as a residual disinfectant. In these contaminated hospitals, the proportion of sites testing positive was inversely correlated with free residual chlorine concentration (<jats:italic>P<\/jats:italic>=.01). In all hospitals, hot-water temperatures were too low to inhibit<jats:italic>Legionella<\/jats:italic>growth.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700072970_abs5\"><jats:title>Conclusions:<\/jats:title><jats:p>The increase in reporting of nosocomial legionnaires' disease was attributable to increased use of urinary antigen tests; prior cases may have gone unrecognized. Risk of legionnaires' disease in hospital patients was better predicted by the proportion of water-system sites testing positive for<jats:italic>Legionella<\/jats:italic>than by the measured concentration of<jats:italic>Legionella<\/jats:italic>bacteria. Use of monochloramine by municipalities for residual drinking water disinfection may help prevent legionnaires' disease.<\/jats:p><\/jats:sec>","DOI":"10.1086\/501587","type":"journal-article","created":{"date-parts":[[2006,2,3]],"date-time":"2006-02-03T21:31:03Z","timestamp":1139002263000},"page":"798-805","source":"Crossref","is-referenced-by-count":149,"title":["Hospital Characteristics Associated With Colonization of Water Systems by<i>Legionella<\/i>and Risk of Nosocomial Legionnaires' Disease: A Cohort Study of 15 Hospitals"],"prefix":"10.1017","volume":"20","author":[{"given":"Jacob L.","family":"Kool","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Bergmire-Sweat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay C.","family":"Butler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ellen W.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah J.","family":"Peabody","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel S.","family":"Massi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph C.","family":"Carpenter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Janet M.","family":"Pruckler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert F.","family":"Benson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Barry S.","family":"Fields","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2015,1,2]]},"reference":[{"key":"S0195941700072970_ref017","doi-asserted-by":"publisher","DOI":"10.2307\/30142014"},{"key":"S0195941700072970_ref022","doi-asserted-by":"crossref","first-page":"1805","DOI":"10.1128\/AEM.61.5.1805-1809.1995","article-title":"Precision and accuracy of recovery of Legionella pneumophila from seeded tap water by filtration and centrifugation","volume":"61","author":"Boulanger","year":"1995","journal-title":"Appl Environ Microbiol"},{"key":"S0195941700072970_ref024","first-page":"1","article-title":"Guidelines for prevention of nosocomial pneumonia","volume":"46","year":"1997","journal-title":"MMWR"},{"key":"S0195941700072970_ref001","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1997.00440360129015"},{"key":"S0195941700072970_ref014","volume-title":"Optimizing Chloramine Treatment","author":"Kirmeyer","year":"1993"},{"key":"S0195941700072970_ref009","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1990.03440210074036"},{"key":"S0195941700072970_ref002","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1994.00420210049006"},{"key":"S0195941700072970_ref006","doi-asserted-by":"publisher","DOI":"10.1017\/S0950268800029526"},{"key":"S0195941700072970_ref011","doi-asserted-by":"publisher","DOI":"10.1093\/clind\/16.6.741"},{"key":"S0195941700072970_ref005","doi-asserted-by":"publisher","DOI":"10.1017\/S0950268800047385"},{"key":"S0195941700072970_ref019","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1981.03320110031022"},{"key":"S0195941700072970_ref008","first-page":"565","article-title":"Factors contributing to the contamination of hospital water distribution systems by legionellae","volume":"165","author":"Alary","year":"1992","journal-title":"Dis"},{"key":"S0195941700072970_ref015","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(98)06394-6"},{"key":"S0195941700072970_ref013","doi-asserted-by":"crossref","first-page":"326","DOI":"10.1128\/JCM.12.3.326-328.1980","article-title":"Indirect immunofluorescence antibodies to Legionella pneumophila: frequency in a rural community","volume":"12","author":"Helms","year":"1980","journal-title":"J Clin Microbiol"},{"key":"S0195941700072970_ref016","doi-asserted-by":"publisher","DOI":"10.1017\/S0195941700067412"},{"key":"S0195941700072970_ref004","doi-asserted-by":"publisher","DOI":"10.1017\/S0950268800049293"},{"key":"S0195941700072970_ref018","first-page":"81","volume-title":"Hospital Licensing Standards","year":"1994"},{"key":"S0195941700072970_ref003","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(83)90629-0"},{"key":"S0195941700072970_ref021","first-page":"275","volume-title":"Current Status and Emerging Perspectives","author":"Bezanson","year":"1993"},{"key":"S0195941700072970_ref010","doi-asserted-by":"publisher","DOI":"10.1016\/0002-9343(93)90227-G"},{"key":"S0195941700072970_ref007","first-page":"416","article-title":"Sustained transmission of nosocomial Legionnaires disease\u2014Arizona and Ohio","volume":"46","year":"1997","journal-title":"MMWR"},{"key":"S0195941700072970_ref012","doi-asserted-by":"publisher","DOI":"10.2307\/30142015"},{"key":"S0195941700072970_ref020","first-page":"307","volume-title":"Lancet","volume":"2","author":"Best","year":"1983"},{"key":"S0195941700072970_ref023","volume-title":"Approaches to Prevention and Control of Legionella Infection in Allegheny County Health Care Facilities","year":"1997"}],"container-title":["Infection Control &amp; Hospital Epidemiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0195941700072970","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,4,12]],"date-time":"2020-04-12T12:44:12Z","timestamp":1586695452000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0195941700072970\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1999,12]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[1999,12]]}},"alternative-id":["S0195941700072970"],"URL":"https:\/\/doi.org\/10.1086\/501587","relation":{},"ISSN":["0899-823X","1559-6834"],"issn-type":[{"value":"0899-823X","type":"print"},{"value":"1559-6834","type":"electronic"}],"subject":[],"published":{"date-parts":[[1999,12]]}}}