{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T05:35:45Z","timestamp":1767159345126,"version":"build-2238731810"},"reference-count":26,"publisher":"Cambridge University Press (CUP)","issue":"6","license":[{"start":{"date-parts":[[2015,1,2]],"date-time":"2015-01-02T00:00:00Z","timestamp":1420156800000},"content-version":"unspecified","delay-in-days":6059,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infect. Control Hosp. Epidemiol."],"published-print":{"date-parts":[[1998,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"S0195941700087828_abs1\">\n                    <jats:title>\n                      <jats:bold>OBJECTIVE:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>To assess the effect on staff- and patient-related complications of a needleless intermittent intravenous access system with a reflux valve for peripheral infusions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs2\">\n                    <jats:title>\n                      <jats:bold>DESIGN:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>A 6-month cross-over clinical trial (phase I, 13 weeks; phase II, 12 weeks) of a needleless intermittent intravenous access system (NL; study device) compared to a conventional heparin-lock system (CHL, control device) was performed during 1991 on 16 medical and surgical units. A random selection of patients was assessed for local intravenous-site complications; all patients were assessed for the development of nosocomial bacteremia and device-related complications. Staff were assessed for percutaneous injuries and participated in completion of product evaluations. A cost analysis of the study compared to the control device was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs3\">\n                    <jats:title>\n                      <jats:bold>SETTING:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>A 1,100-bed, teaching, referral medical center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs4\">\n                    <jats:title>\n                      <jats:bold>PATIENTS AND STAFF PARTICIPANTS:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>594 patients during 602 patient admissions, comprising a random sample of all patients with a study or control device inserted within a previous 24-hour period on study and control units, were assessed for local complications. The 16 units included adult inpatient general medicine, surgical, and subspecialty units. Pediatrics, obstetrics-gynecology, and intensive-care units were excluded. All patients on study and control units were assessed for development of nosocomial bacteremia and device-related complications. All staff who utilized, manipulated, or may have been exposed to sharps on study and control units were assessed for percutaneous injuries. Nursing staff completed product evaluations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs5\">\n                    <jats:title>\n                      <jats:bold>INTERVENTION:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>The study device, a needleless intermittent intravenous access system with a reflux valve, was compared to the control device, a conventional heparin lock, for peripheral infusions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs6\">\n                    <jats:title>\n                      <jats:bold>RESULTS:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>\n                      During the study, 35 percutaneous injuries were reported. Eight injuries were CHL-related; no NL-related injuries were reported (\n                      <jats:italic>P<\/jats:italic>\n                      =.007). An evaluation of 602 patient admissions, 1,134 intermittent access devices, and 2,268 observed indwelling device days demonstrated more pain at the insertion site for CHL than NL; however, no differences in objective signs of phlebitis were noted. Of 773 episodes of positive blood cultures on study and control units, 6 (0.8%) were device-related (assessed by blinded investigator), with no difference between NL and CHL. Complications, including difficulty with infusion (\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001) and disconnection of intravenous tubing from device (\n                      <jats:italic>P<\/jats:italic>\n                      &lt;.001), were reported more frequently with CHL than with NL. Of nursing staff responding to a product evaluation survey, 95.2% preferred the study over control device. The projected annual incremental cost to our institution for hospitalwide implementation of NL for intermittent access for peripheral infusions was estimated at $82,845, or $230 per 1,000 patient days.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"S0195941700087828_abs7\">\n                    <jats:title>\n                      <jats:bold>CONCLUSIONS:<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>A needleless intermittent intravenous access system with a reflux valve for peripheral infusions is effective in reducing percutaneous injuries to staff and is not associated with an increase in either insertion-site complications or nosocomial bacteremia. Institutions should consider these data, available institutional resources, and institution-specific data regarding the frequency and risk of intermittent access-device-related injuries and other types of sharps injuries in their staff when selecting the above or other safety devices.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1086\/647839","type":"journal-article","created":{"date-parts":[[2009,9,9]],"date-time":"2009-09-09T15:52:29Z","timestamp":1252511549000},"page":"401-406","source":"Crossref","is-referenced-by-count":56,"title":["Study of a Needleless Intermittent Intravenous-Access System for Peripheral Infusions: Analysis of Staff, Patient, and Institutional Outcomes"],"prefix":"10.1017","volume":"19","author":[{"given":"Meryl H.","family":"Mendelson","sequence":"first","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Louise J.","family":"Short","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Clyde B.","family":"Schechter","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Burt R.","family":"Meyers","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Margarita","family":"Rodriguez","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Cohen","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Lozada","sequence":"additional","affiliation":[{"name":"Mount Sinai School of Medicine of the City University of New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marvalyn","family":"DeCambre","sequence":"additional","affiliation":[{"name":"Mount Sinai School of Medicine of the City University of New York"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shalom Z.","family":"Hirschman","sequence":"additional","affiliation":[{"name":"the Mount Sinai Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2015,1,2]]},"reference":[{"key":"S0195941700087828_bib010","volume-title":"Proceedings of 31st Interscience Conference on Antimicrobial Agents and Chemotherapy","author":"Short","year":"1991"},{"key":"S0195941700087828_bib007","doi-asserted-by":"publisher","DOI":"10.1177\/0310057X8801600305"},{"key":"S0195941700087828_bib019","doi-asserted-by":"publisher","DOI":"10.1086\/646523"},{"key":"S0195941700087828_bib004","unstructured":"Occupational Safety and Health Administration. Jane Doe, San Francisco General Hospital; Service Employees International Union, Holiday Inn, Union Square, January 16, 1990. Exhibit no. 214-F. OSHA transcript from informal public hearing. Proposed rule on occupational exposure to bloodborne pathogens, pages 693\u2013699."},{"key":"S0195941700087828_bib025","article-title":"Central venous catheter (CVC)-associated bloodstream infections (BSI) in intensive care unit patients associated with needleless access devices","volume":"18","author":"McDonald","year":"1997","journal-title":"Infect Control Hosp Epidemiol"},{"key":"S0195941700087828_bib001","first-page":"64175","volume":"56","year":"1991","journal-title":"Federal Register"},{"key":"S0195941700087828_bib008","first-page":"288","article-title":"Complications of intravenous therapy: a randomized prospective study\u2014vialon vs teflon","volume":"127","author":"Mckee","year":"1989","journal-title":"J Intraven Nurs"},{"key":"S0195941700087828_bib016","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(95)90264-3"},{"key":"S0195941700087828_bib013","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-6553(05)80005-7"},{"key":"S0195941700087828_bib014","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(93)90206-J"},{"key":"S0195941700087828_bib005","volume-title":"Guidelines for prevention of intravenous therapy related infections","author":"Simmons","year":"1981"},{"key":"S0195941700087828_bib018","doi-asserted-by":"publisher","DOI":"10.1086\/646751"},{"key":"S0195941700087828_bib002","volume-title":"Needlestick and other risks from hypodermic needles on secondary IV, administration sets\u2014piggyback and intermittent IV","author":"Benson","year":"1992"},{"key":"S0195941700087828_bib021","volume-title":"Proceedings of 34th Interscience Conference on Antimicrobial Agents and Chemotherapy","author":"Maki","year":"1994"},{"key":"S0195941700087828_bib023","volume-title":"Proceedings of 35th Interscience Conference on Antimicrobial Agents and Chemotherapy","author":"Kellerman","year":"1995"},{"key":"S0195941700087828_bib026","first-page":"21","article-title":"Evaluation of safety devices for preventing percutaneous injuries among health-care workers during phlebotomy procedures\u2014Minneapolis\u2014St. Paul, New York City, and San Francisco, 1993-1995","volume":"46","year":"1997","journal-title":"MMWR"},{"key":"S0195941700087828_bib015","doi-asserted-by":"publisher","DOI":"10.2307\/30149733"},{"key":"S0195941700087828_bib024","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(95)90266-X"},{"key":"S0195941700087828_bib017","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1994.03520080049042"},{"key":"S0195941700087828_bib012","volume-title":"Proceedings of Third Annual Meeting of the Society for Hospital Epidemiology of America","author":"Mendelson","year":"1993"},{"key":"S0195941700087828_bib003","volume-title":"Proceedings of 31st Interscience Conference on Antimicrobial Agents and Chemotherapy","author":"Mendelson","year":"1991"},{"key":"S0195941700087828_bib011","volume-title":"A National Conference on Prevention of Device Mediated Bloodborne Infections, Occupational Safety and Health Administration.","author":"Juliett","year":"1992"},{"key":"S0195941700087828_bib022","doi-asserted-by":"publisher","DOI":"10.1001\/jama.1995.03520470070034"},{"key":"S0195941700087828_bib009","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(88)90053-3"},{"key":"S0195941700087828_bib020","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(93)90419-5"},{"key":"S0195941700087828_bib006","volume-title":"Pilot study of needlestick prevention devices: report to the legislature","author":"Chiarello","year":"1992"}],"container-title":["Infection Control &amp; Hospital Epidemiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0195941700087828","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T08:15:56Z","timestamp":1762848956000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0195941700087828\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1998,6]]},"references-count":26,"aliases":["10.2307\/30142428"],"journal-issue":{"issue":"6","published-print":{"date-parts":[[1998,6]]}},"alternative-id":["S0195941700087828"],"URL":"https:\/\/doi.org\/10.1086\/647839","relation":{},"ISSN":["0899-823X","1559-6834"],"issn-type":[{"value":"0899-823X","type":"print"},{"value":"1559-6834","type":"electronic"}],"subject":[],"published":{"date-parts":[[1998,6]]}}}