{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,12]],"date-time":"2026-07-12T01:35:14Z","timestamp":1783820114546,"version":"3.55.0"},"reference-count":15,"publisher":"Cambridge University Press (CUP)","issue":"2","license":[{"start":{"date-parts":[[2015,1,2]],"date-time":"2015-01-02T00:00:00Z","timestamp":1420156800000},"content-version":"unspecified","delay-in-days":1066,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infect. Control Hosp. Epidemiol."],"published-print":{"date-parts":[[2012,2]]},"abstract":"<jats:sec id=\"S0195941700030630_abs1\"><jats:title>Objective.<\/jats:title><jats:p>To detect an outbreak-related source of <jats:italic>Legionella,<\/jats:italic> control the outbreak, and prevent additional <jats:italic>Legionella<\/jats:italic> infections from occurring.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700030630_abs2\"><jats:title>Design and Setting.<\/jats:title><jats:p>Epidemiologic investigation of an acute outbreak of hospital-associated Legionnaires disease among outpatients and visitors to a Wisconsin hospital.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700030630_abs3\"><jats:title>Patients.<\/jats:title><jats:p>Patients with laboratory-confirmed Legionnaires disease who resided in southeastern Wisconsin and had illness onsets during February and March 2010.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700030630_abs4\"><jats:title>Methods.<\/jats:title><jats:p>Patients with Legionnaires disease were interviewed using a hypothesis-generating questionnaire. On-site investigation included sampling of water and other potential environmental sources for <jats:italic>Legionella<\/jats:italic> testing. Case-finding measures included extensive notification of individuals potentially exposed at the hospital and alerts to area healthcare and laboratory personnel.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700030630_abs5\"><jats:title>Results.<\/jats:title><jats:p>Laboratory-confirmed Legionnaires disease was diagnosed in 8 patients, all of whom were present at the same hospital during the 10 days prior to their illness onsets. Six patients had known exposure to a water wall-type decorative fountain near the main hospital entrance. Although the decorative fountain underwent routine cleaning and maintenance, high counts of <jats:italic>Legionella pneumophila<\/jats:italic> serogroup 1 were isolated from cultures of a foam material found above the fountain trough.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700030630_abs6\"><jats:title>Conclusion.<\/jats:title><jats:p>This outbreak of Legionnaires disease was associated with exposure to a decorative fountain located in a hospital public area. Routine cleaning and maintenance of fountains does not eliminate the risk of bacterial contamination. Our findings highlight the need to evaluate the safety of water fountains installed in any area of a healthcare facility.<\/jats:p><jats:p><jats:italic>Infect Control Hosp Epidemiol<\/jats:italic> 2012;33(2):185-191<\/jats:p><\/jats:sec>","DOI":"10.1086\/663711","type":"journal-article","created":{"date-parts":[[2012,1,6]],"date-time":"2012-01-06T22:57:25Z","timestamp":1325890645000},"page":"185-191","source":"Crossref","is-referenced-by-count":74,"title":["An Outbreak of Legionnaires Disease Associated with a Decorative Water Wall Fountain in a Hospital"],"prefix":"10.1017","volume":"33","author":[{"given":"Thomas E.","family":"Haupt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard T.","family":"Heffernan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James J.","family":"Kazmierczak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henry","family":"Nehls-Lowe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce","family":"Rheineck","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christine","family":"Powell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathryn K.","family":"Leonhardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amit S.","family":"Chitnis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey P.","family":"Davis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"56","published-online":{"date-parts":[[2015,1,2]]},"reference":[{"key":"S0195941700030630_ref012","volume-title":"Standard Methods for the Examination of Water and Wastewater","year":"2005"},{"key":"S0195941700030630_ref011","year":"1994"},{"key":"S0195941700030630_ref010","unstructured":"Environmental assessment of water systems. Centers for Disease Control and Prevention Web site. http:\/\/www.cdc.gov\/legionella\/files\/EnvironmentalAssessmentlnstrument.pdf. Accessed March 9, 2010."},{"key":"S0195941700030630_ref007","first-page":"117","article-title":"Legionella contamination in the water system of hospital dental settings","volume":"78","author":"Veronesi","year":"2007","journal-title":"Acta Biomed"},{"key":"S0195941700030630_ref003","doi-asserted-by":"publisher","DOI":"10.1086\/647689"},{"key":"S0195941700030630_ref002","doi-asserted-by":"publisher","DOI":"10.1086\/648664"},{"key":"S0195941700030630_ref001","doi-asserted-by":"publisher","DOI":"10.1111\/j.1532-5415.2000.tb03868.x"},{"key":"S0195941700030630_ref004","doi-asserted-by":"publisher","DOI":"10.1086\/598855"},{"key":"S0195941700030630_ref006","doi-asserted-by":"publisher","DOI":"10.1186\/1471-2334-7-93"},{"key":"S0195941700030630_ref008","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhin.2005.05.001"},{"key":"S0195941700030630_ref009","doi-asserted-by":"publisher","DOI":"10.1001\/archinte.1996.00440140115011"},{"key":"S0195941700030630_ref015","volume-title":"Guidelines for Design and Construction of Health Care Facilities","volume":"16","year":"2010"},{"key":"S0195941700030630_ref014","first-page":"1","volume-title":"Morb Mortal Wkly Rep","volume":"52","year":"2003"},{"key":"S0195941700030630_ref013","volume-title":"Minimizing the Risk of Legionellosis Associated with Building Water Systems","volume":"4","year":"2000"},{"key":"S0195941700030630_ref005","doi-asserted-by":"publisher","DOI":"10.1093\/oxfordjournals.aje.a116895"}],"container-title":["Infection Control &amp; Hospital Epidemiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0195941700030630","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,4,26]],"date-time":"2019-04-26T01:47:46Z","timestamp":1556243266000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0195941700030630\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,2]]},"references-count":15,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2012,2]]}},"alternative-id":["S0195941700030630"],"URL":"https:\/\/doi.org\/10.1086\/663711","relation":{},"ISSN":["0899-823X","1559-6834"],"issn-type":[{"value":"0899-823X","type":"print"},{"value":"1559-6834","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,2]]}}}