{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,6]],"date-time":"2022-04-06T04:21:31Z","timestamp":1649218891812},"reference-count":21,"publisher":"Cambridge University Press (CUP)","issue":"11","license":[{"start":{"date-parts":[[2015,1,2]],"date-time":"2015-01-02T00:00:00Z","timestamp":1420156800000},"content-version":"unspecified","delay-in-days":792,"URL":"https:\/\/www.cambridge.org\/core\/terms"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Infect. Control Hosp. Epidemiol."],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:sec id=\"S0195941700041874_abs1\"><jats:title>Background.<\/jats:title><jats:p>Despite a proliferation of phlebotomy devices with engineered sharps injury protection (ESIP), the impact of various winged device designs on blood splatter occurring during venipuncture procedures has not been explored.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700041874_abs2\"><jats:title>Objectives.<\/jats:title><jats:p>To evaluate the potential for blood splatter of 6 designs of winged phlebotomy devices.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700041874_abs3\"><jats:title>Design.<\/jats:title><jats:p>A laboratory-based device evaluation without human subjects, using a simulated patient venous system.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700041874_abs4\"><jats:title>Methods.<\/jats:title><jats:p>We evaluated 18 winged phlebotomy devices of 6 device designs by Terumo, BD Vacutainer (2 designs), Greiner, Smith Medical, and Kendall (designated A-F, respectively). Scientific filters were positioned around the devices and weighed before and after venipuncture was performed. Visible blood on filters, exam gloves, and devices and measurable blood splatter were the primary units of analysis.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700041874_abs5\"><jats:title>Results.<\/jats:title><jats:p>The percentages of devices and gloves with visible blood on them and filters with measurable blood splatter ranged from 0% to 20%. There was a statistically significant association between device design and visible blood on devices (<jats:italic>P<\/jats:italic>&lt; .0001) and between device design and filters with measurable blood splatter (<jats:italic>P<\/jats:italic>&lt; .0001), but not between device design and visible blood on gloves. A wide range of associations were demonstrated between device design and visible blood on gloves or devices and incidence of blood splatter.<\/jats:p><\/jats:sec><jats:sec id=\"S0195941700041874_abs6\"><jats:title>Conclusions.<\/jats:title><jats:p>The results of this evaluation suggest that winged phlebotomy devices with ESIP may produce blood splatter during venipuncture. Reinforcing the importance of eye protection and developing a methodology to assess ocular exposure to blood splatter are major implications for healthcare personnel who use these devices. Future studies should focus on evaluating different designs of intravascular devices (intravenous catheters, other phlebotomy devices) for blood splatter.<\/jats:p><\/jats:sec>","DOI":"10.1086\/668030","type":"journal-article","created":{"date-parts":[[2012,10,5]],"date-time":"2012-10-05T21:16:53Z","timestamp":1349471813000},"page":"1069-1076","source":"Crossref","is-referenced-by-count":3,"title":["Contribution of a Winged Phlebotomy Device Design to Blood Splatter"],"prefix":"10.1017","volume":"33","author":[{"given":"Donna J.","family":"Haiduven","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christine","family":"McGuire-Wolfe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shawn P.","family":"Applegarth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"56","published-online":{"date-parts":[[2015,1,2]]},"reference":[{"key":"S0195941700041874_ref009","doi-asserted-by":"publisher","DOI":"10.1080\/15298668791384733"},{"key":"S0195941700041874_ref014","doi-asserted-by":"publisher","DOI":"10.1016\/0196-6553(95)90063-2"},{"key":"S0195941700041874_ref016","doi-asserted-by":"publisher","DOI":"10.4314\/eamj.v85i9.9660"},{"key":"S0195941700041874_ref013","unstructured":"Safety feature evaluation forms. Training for Development of Innovative Control Technologies (TDICT) Project website. http:\/\/www.tdict.org\/evaluation2.html. Published 1990. Accessed December 21, 2011."},{"key":"S0195941700041874_ref002","unstructured":"Occupational exposure to blood borne pathogens: needle stick and other sharps injuries; final rule 2001. Occupational Safety and Health Administration website. http:\/\/www.osha.gov\/SLTC\/bloodbornepathogens\/standards.html. Published 2001. Accessed December 21, 2011."},{"key":"S0195941700041874_ref007","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2003.03.005"},{"key":"S0195941700041874_ref005","doi-asserted-by":"publisher","DOI":"10.1016\/S0196-6553(97)90011-0"},{"key":"S0195941700041874_ref008","doi-asserted-by":"crossref","first-page":"257","DOI":"10.5694\/j.1326-5377.1990.tb136896.x","article-title":"AIDS and hepatitis B and C: contamination risk at transurethral resection: a study using sodium fluorescein as a marker","volume":"153","author":"Taylor","year":"1990","journal-title":"Med J Aust"},{"key":"S0195941700041874_ref001","unstructured":"Needlestick Safety and Prevention Act. Pub L No. 104\u2013130. H.R. 5178 (2000)."},{"key":"S0195941700041874_ref015","first-page":"42","article-title":"How to evaluate sharp safety engineered devices","volume":"104","author":"Ford","year":"2008","journal-title":"Nurs Times"},{"key":"S0195941700041874_ref021","doi-asserted-by":"publisher","DOI":"10.7748\/ns.25.43.41.s48"},{"key":"S0195941700041874_ref003","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2008.03.004"},{"key":"S0195941700041874_ref019","doi-asserted-by":"publisher","DOI":"10.1016\/S0009-9260(05)82917-4"},{"key":"S0195941700041874_ref011","first-page":"1","article-title":"Updated U.S. Public Health Service guidelines for the management of occupational exposures to HBV, HCV, and HIV and recommendations for postexposure prophylaxis","volume":"50","year":"2001","journal-title":"MMWR Recomm Rep"},{"key":"S0195941700041874_ref017","first-page":"73","article-title":"Quantification of facial contamination with blood during orthopedic procedures","volume":"45","author":"Collins","year":"2000","journal-title":"JHosp Infect"},{"key":"S0195941700041874_ref010","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1128\/CMR.8.3.389","article-title":"Laboratory-associated infections and biosafety","volume":"8","author":"Sewell","year":"1995","journal-title":"Clin Microbiol Rev"},{"key":"S0195941700041874_ref018","first-page":"618","article-title":"Eye protection in ear, nose and throat surgery","volume":"107","author":"Prior","year":"1993","journal-title":"J Otolaryngol"},{"key":"S0195941700041874_ref006","doi-asserted-by":"publisher","DOI":"10.3109\/00365549309008497"},{"key":"S0195941700041874_ref020","doi-asserted-by":"publisher","DOI":"10.1046\/j.1365-2044.2002.02571.x"},{"key":"S0195941700041874_ref012","unstructured":"Workbook for designing, implementing, and evaluating a sharps injury prevention program. Centers for Disease Control and Prevention website. http:\/\/www.cdc.gov\/sharpssafety\/index.html. Published 2008. Accessed March 16, 2012."},{"key":"S0195941700041874_ref004","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajic.2007.04.197"}],"container-title":["Infection Control &amp; Hospital Epidemiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.cambridge.org\/core\/services\/aop-cambridge-core\/content\/view\/S0195941700041874","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,14]],"date-time":"2020-07-14T13:56:25Z","timestamp":1594734985000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.cambridge.org\/core\/product\/identifier\/S0195941700041874\/type\/journal_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":21,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["S0195941700041874"],"URL":"https:\/\/doi.org\/10.1086\/668030","relation":{},"ISSN":["0899-823X","1559-6834"],"issn-type":[{"value":"0899-823X","type":"print"},{"value":"1559-6834","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11]]}}}